My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9314
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9314
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:17:03 AM
Creation date
3/22/2011 8:11:22 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9314
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Joint Restraint for AWWA PVC Pipe Sample Specification <br /> • <br /> • (The text of the specification below can be downloaded as a Microsoft® Word Doc from t www.el I , r:.i ] ) <br /> Restraint devices for mechanical joint fittings and appurtenances conforming to either ANSI /AWWA C111/A21.11 or ANSI /AWWA <br /> C153/A2153, shall conform to the follow: <br /> Design the casting. These Material Traceability through 24 inch, shall meet or exceed the <br /> Restraint devices for nominal pipe sizes Records (MTR's) are to be made requirements of ASTM F1674 of the latest <br /> 3 inch through 36 inch shall consist of available, in hard copy, to the purchaser revision. <br /> multiple gripping wedges incorporated that requests such documentation and Mechanical joint restraint shall be Series <br /> into a follower gland meeting the submits his gland body identification 2000PV produced by EBAA Iron Inc. or <br /> applicable requirements of ANSI /AWWA number. approved equal. <br /> C110/A21.10. Production pieces that are too small to <br /> The devices shall have a working pressure accommodate individual numbering, <br /> rating equal to that of the pipe on which such as fasteners and wedges, shall be <br /> it is used. Ratings are for water pressure controlled in segregate inventory until MEGA -BOND Restraint Coating System <br /> and must include a minimum safety factor such time as all quality control tests are All wedge assemblies and related parts <br /> of 2:1 in all sizes. passed. These component parts may shall be processed through a phosphate <br /> then be released to a general inventory for wash, rinse and drying operation prior <br /> Material final assembly and packaging. to coating application. The coating shall <br /> Gland body, wedges and wedge actuating All components shall be manufactured consist of a minimum of two coats of <br /> components shall be cast from grade 65- and assembled in the United States. The liquid Xylan® fluoropolymer coating with <br /> 45 -12 ductile iron material in accordance purchaser shall, with reasonable notice, heat cure to follow each coat. <br /> with ASTM A536. have the right to plant visitation at his /her <br /> Ductile iron gripping wedges shall be heat expense. All casting bodies shall be surface <br /> treated within a range of 370 to 470 BHN. pretreated with a phosphate wash, rinse <br /> Three (3) test bars shall be incrementally Installation and sealer before drying. The coating <br /> poured per production shift as per Mechanical joint restraint shall require shall be electrostatically applied and heat <br /> Underwriter's Laboratory (U.L.) conventional tools and installation cured. The coating shall be a polyester <br /> Specifications and ASTM A536. Testing for procedures per AWWA C600, while based powder to provide corrosion, impact <br /> tensile, yield and elongation shall be done retaining full mechanical joint deflection and UV resistance. <br /> in accordance with ASTM E8. during assembly. <br /> Chemical and nodularity tests shall be Proper actuation of the gripping wedges The coating system shall be MEGA -BOND <br /> performed as recommended by the shall be ensured with torque limiting twist by EBAA Iron, Inc. or approved equal. <br /> Ductile Iron Society, on a per ladle basis. off nuts. Requests for approved equal must submit <br /> coating material and process details for <br /> Traceability Approvals review prior to bid. <br /> An identification number consisting of Mechanical Joint Restraints shall be <br /> year, day, plant and shift (YYDDD) (plant Listed by Underwriters Laboratories in the Xytan is !registered trademark of the Whitford <br /> designation) (Shift number), shall be cast 4 inch through 12 inch sizes. Corporation. <br /> into each gland body. Mechanical Joint Restraints shall be <br /> All physical and chemical test results Factory Mutual Approved in the 4 inch For more information regarding MEGA - <br /> shall be recorded such that they can be through 12 inch sizes. BOND, refer to the MEGA BOND brochure <br /> accessed via the identification number on Mechanical Joint Restraints, 4 inch or visit www.ebaa.com. <br /> k E <br /> 7r� i• <br /> M s �� . �a �.°�E@, ` f <br /> k , :� a a a cerni • a a a <br /> ® trarnt for 09 PVC > <br /> fi <br /> i ,, s r , ,„ ,stthint fora P fa d ':� <br /> d 6 <br /> �� P ` <br /> r y <br /> • <br /> �IEC7ALUC7� Restraint Harness ` <br /> • PVC: <br /> Sizes'14 inch through 48 Serde, x'2000 <br /> Sizes 4 "throe h 12'.accornm dared <br /> Split MEtAIUfv Resttatrit for exisung <br /> ,� � Senes 100 or T6f3(j <br /> 0900 PVC Pipe at IDuct Iran Fitttngs 3 hU� <br /> Sizes 4 inch through 12``" 4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.