My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 16, 2004 DN -7001 • A1-380 <br /> ® NOT- BG12LX <br /> NOTIFIER Addressable Manual Pull Station <br /> for FireWarden -100 <br /> Section: Addressable <br /> GENERAL Patented, U.S Patent No. D428,351; 6,380,846 <br /> U.S. Patent Pending: 091686,286 <br /> The NOTIFIER NOT- BG12LX is a state -of- the -art, dual -ac- <br /> tion (Le., requires two motions to activate the station) pull <br /> station that includes an addressable interface (mounted in- <br /> side) for NOTIFIER's addressable FireWarden -100 fire alarm <br /> (l a <br /> control panel. Because the NOT- BG12LX is addressable, <br /> the control panel can display the exact location of the acti- <br /> vated manual pull station. This leads fire service personnel LISTED <br /> quickly to the location of the alarm. S692 <br /> FEATURES <br /> • Aesthetically pleasing, highly visible, dual- action design. <br /> • Meets ADA 5 lb. maximum pull force. <br /> • Easily operated (dual- action). `: <br /> • Attractive shape and textured finish. <br /> • Mounts, semi - flush, to a standard single gang (2.125" <br /> [5.398 cm] minimum depth), double -gang, or 4.0" (10.16 <br /> cm) square electrical box. <br /> • When the handle latches in down position, the word "AC- <br /> TIVATED" appears at the top of the handle in bright yellow <br /> to clearly indicate the station has been operated. r. <br /> • Key /lock reset; needs only a 1/4 -turn to lock/unlock. <br /> • Includes Braille text on station handle. <br /> • Captive screw terminals wire -ready for easy connection <br /> to SLC loop (accepts up to 12 AWG /3.1 mm wire). `` <br /> • Optional trim ring (BG-TR). <br /> • Meets UL 38, Standard for Manually Actuated Signaling <br /> Boxes. <br /> • Maintenance personnel can open station (for inspection <br /> and testing) without causing an alarm condition. , <br /> • Built -in bicolor LED, which is visible through the handle of <br /> the station, flashes red in normal operation and latches <br /> on steady red when in alarm. <br /> ENGINEERING SPECIFICATIONS <br /> Manual Fire Alarm Stations shall be non -code, with a key- The NOT- BGI2IJC <br /> operated reset lock in order that they may be tested, and so Addressable Manual Pull Station <br /> designed that after actual Emergency Operation, they can- <br /> not be restored to normal except by use of a key. An oper- by the Americans with Disabilities Act (ADA) or per national/ <br /> ated station shall automatically condition itself so as to be local requirements. Manual Stations shall be Underwriters <br /> visually detected as activated. Manual stations shall be con- Laboratories listed. <br /> structed of red - colored LEXAN® (or polycarbonate equiva- <br /> lent) with clearly visible operating instructions provided on Manual stations shall connect with two wires to one of the <br /> the cover. The word FIRE shall appear on the front of the control panel SLC loops. The manual station shall, on com- <br /> stations in white letters, 1.00 inches (2.54 cm) or larger. Sta- mand from the control panel, send data to the panel repre- <br /> tions shall be suitable for surface mounting on matching senting the state of the manual switch. Manual stations shall <br /> backbox SB -10 or SB -I /O; or semi -flush mounting on a stan- provide address setting by use of rotary decimal switches. <br /> dard single -gang, double -gang, or 4.0" (10.16 cm) square ELECTRICAL SPECIFICATIONS <br /> electrical box, and shall be installed within the limits defined <br /> Normal operating voltage: 24 VDC. <br /> LEXAN® is a registered trademark of GE Plastics, Maximum SLC loop voltage: 28.0 VDC. <br /> a subsidiary of General Electric Company. Maximum SLC loop current: 230 pA. <br /> a Honeywell . <br /> This ISO 9001 <br /> This s document t is not intended ed to to be be used for installation purposes. We try to keep our <br /> product information up -to -date and accurate. We cannot cover all specific applications <br /> or anticipate all requirements. All specifications are subject to change without notice. For C E R T 1 F 1 E D <br /> more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 ENI/EINI W IFACIU <br /> N OT I F I E R 12 Clintonville Road, Northford, Connecticut 06472 QUALITY S Y S T E M S <br /> DN -7001. 09/16/04 — Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.