Laserfiche WebLink
October 25, 2004 ON -7000 • A1-360 <br /> ® NC -100 and NC -100R <br /> N OT I F I E R Control and Relay Modules <br /> for the FireWarden -100 <br /> Section: Addressable <br /> GENERAL <br /> The NC -100 Addressable Control Module provides California <br /> NOTIFIER's FireWarden -100 intelligent control panels a su � State Fi <br /> �. ` Marshal <br /> pervised Class B (Style Y) or Class A (Style Z) circuit for Noti- u <br /> fication Appliances (horns, strobes, etc.. Addressabilit al pp� 7300- 0028:230 <br /> lows the NC -100 to be activated, either manually or through LISTED <br /> panel programming, on a select (zone or area of coverage) S635 <br /> basis. <br /> The NC -100R Addressable Relay Module provides the <br /> FireWarden -100 system with two isolated sets of Form -C <br /> dry- contact outputs for activating a variety of auxiliary de- <br /> vices, such as fans, dampers, door holders, control equip- �� . <br /> SON fRC1 <br /> ment, etc. Addressability allows the dry contact to be acti- <br /> vated, either manually or through panel programming, on <br /> a select basis. <br /> FEATURES r,w <br /> • Built -in type identification automatically identifies these <br /> devices to the control panel. I ti A <br /> • Internal circuitry and relay powered directly by two -wire 0:1.1 t 1 <br /> SLC loop. The NC -100 module requires power (for y % <br /> horns, strobes, etc.). I <br /> • Integral LED "blinks" green each time a communication <br /> g am_ <br /> is received from the control panel and turns on steady - <br /> when activated. <br /> • High noise immunity (EMF /RFI). <br /> • The NC 100 may be used to switch 24 volt NAC power. <br /> a llb <br /> • Wide viewing angle of LED. <br /> • SEMS screws with clamping plates for wiring ease. <br /> • Direct Decade 01 -99 (FireWarden -100) entry of address. NC -100 and NC -100R module <br /> APPLICATIONS <br /> The NC -100 is used to switch 24 VDC audible /visual power. its internal relay. The NC -100 supervises Class B (Style Y) <br /> The NC -100R may be programmed to operate dry contacts or Class A (Style Z) notification or control circuits. <br /> for door holders, Air Handling Unit shutdown, etc. Upon code command from the panel, the NC -100 will dis- <br /> CONSTRUCTION connect the supervision and connect the external power <br /> supply in the proper polarity across the load device. The <br /> • The face plate is made of off -white Noryl®. disconnection of the supervision provides a positive indi- <br /> • Controls include two rotary switches for direct -dial entry cation to the panel that the control relay actually turned ON. <br /> of address (01 -99 on the FireWarden -100). The external power supply is always relay isolated from <br /> • The NC -100 is configured for a single Class B (Style Y) the communication loop so that a trouble condition on the <br /> or Class A (Style Z) Notification Appliance Circuit. extemal power supply will never interfere with the rest of <br /> • The NC -100R provides two Form -C dry contacts that the system. <br /> switch together. Rotary switches set a unique address for each module. <br /> OPERATION The address may be set before or after mounting. The <br /> built -in TYPE CODE (not settable) will identify the module <br /> Each NC -100 or NC -100R uses one of 99 (FireWarden- to the control panel, so as to differentiate between a mod - <br /> 100) possible module addresses on a SLC loop. It re- ule and a sensor address. <br /> sponds to regular polls from the control panel and reports <br /> its type and status, including the open /normal /short sta- <br /> tus of its Notification Appliance Circuit (NAC). The LED Noryl® is a registered trademark of GE Plastics, a subsidiary of <br /> blinks with each poll received. On command, it activates General Electric Company. <br /> This document a Honeywell company. ISO 9001 <br /> This docucumeent t is not intended to be used for installation purposes. We try to keep our <br /> product information up -to -date and accurate. We cannot cover all specific applications <br /> or anticipate all requirements. All specifications are subject to change without notice. C E R T tl F I E 6 <br /> For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 EMGMEfpNi f MIIAIFAC1ialM <br /> 0 N OTI F I E R" 12 Clintonville Road, Northford, Connecticut 06472 Q 11 A L 1 T Y SYSTEMS <br /> DN -7000 • 10/25/04 — Page 1 of 2 <br />