My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9335
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9335
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:23:55 AM
Creation date
3/22/2011 8:20:24 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
09-9335
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS INC
Address
6748 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SpectrAlert Advance Specifications <br /> Architect /Engineer Specifications <br /> General <br /> SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4 x 12 -inch back box, 4-inch octagon back box or double -yang back <br /> box. Two-wire products shall also !mount to a single -gang 2 x 4 x 11/4-inch back box. A universal mounting plate shall be used for mounting ceiling and wall <br /> products. the notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products. when used with the <br /> Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When <br /> used with the Sync •Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification <br /> appliance circuit outputs shall operate between 17 and 33 volts. indoor SpectrAlert Advance products shall operate between :32 and 120 degrees Fahrenheit <br /> from a regulated DE, or full-wave rectned, unfiltered power supply. Strobes and horn/strobes shall have field - selectable candela settings including 15. 5,/75, 30, <br /> 75, 95, 110, 1 1 , 1 35, 150, 177, 185, <br /> Strobe <br /> The strobe shall he a System Sensor SpectrAlert Advance fvlodel listed to Ul 1971 and shall be approved for fire protective service. The strobe shall be <br /> wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at <br /> 1 liz. over the strobes entire operating voltage rands.-The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. <br /> Horn /Strobe Combination <br /> The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to 01 1971 and 01 464 and shall he approved for fire protective service. <br /> The horn /strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible <br /> signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated <br /> lens/reflector system. he horn shall have three audibility options and an option to switch between a temporal three• pattern and a nor.-temporal (continuous) <br /> pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The Horn on <br /> horn/strobe models snail operate on a coded or non -coded power supply. <br /> Outdoor Products <br /> SpectrAlert Advance outdoor horns, strobes and horn /strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 <br /> degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with halt inch and three - fourths inch conduit <br /> entries. <br /> Synchronization Module <br /> the module shall be a System Sensor Sync•C ircuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize <br /> SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn /strobe models over a <br /> single pair of wires. The module shah mount to a 4 4n1/26 x 21/4-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z <br /> (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they <br /> control. The module shall not operate on a coded power supply. <br /> Physical /Electrical Specifications <br /> Standard Operating Temperature 32 °F to 120°F (0 to 49 °C) <br /> K Series Operating Temperature -40`F 10 151 (- 40 °C to 66t) <br /> Humidity Range 10 to 9355 non - condensing (indoor products) <br /> Strobe Flash Rate 1 flash per second <br /> Nominal Voltage Regulated 12DC /FWR or regulated 24DC/FWR' <br /> Operating Voltage Range 8 to 17.5V (12V nominal) or 16 to 33 V (24 nominal) <br /> Input terminal wire gauge 12 to 18 AWG <br /> Ceiling mount dimensions (including lens) 6 8 x 2.5 high (1 73 mm diameter x 64 rnm high) <br /> Wall mount dimensions (including Tens) 5.6 T x 4./W x 2.51? (142 rnm L x 119 mrn W x 64 mrn 0) <br /> Horn dimensions 5.61. x 4, 71N x 1.3 D (142 mm x 119 mrn W x 33 rnm D) <br /> Wail -mount back box skirt dimensions (BBS -2, BBSW -2) 5.9 "L x 5.0W x 2.2D (151 mm L x 128 mrn W x 56 mm 0) <br /> Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7 1-diameter x 2.25 "high (180 mrn diameter x 57 mm high) <br /> Wall -mount weatherproof back box dimensions (SA -WBB) 5.73 x 5.1 W x 2.0"D (145 rnm 1 x ( .' 1 mm W x 51 Him 0) <br /> Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 "diameter x 2.0" high (180 Harr diameter x 5' mm high) <br /> Notes; <br /> 1.:1r11 Wave Rectified (1 voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs, <br /> 2. P. S, PC. and SC products will operate at. 12 '•1 nominal only for 15 and 15/75 cd. <br />