. _ <br /> tijcci Fire & Building <br /> Products <br /> Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 <br /> Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Quick Response, Standard Coverage <br /> General tained when exposed to corrosive at- <br /> mospheres. Although corrosion resin _ <br /> Cant coated sprinklers have passed the <br /> Description standard corrosion tests of the appli- „=` t __ <br /> cable approval agencies, the testing is . „' <br /> The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor- <br /> 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it <br /> dent Sprinklers described in this data is recommended that the end user be ; <br /> sheet are quick response - standard consulted with respect to the suitability <br /> fit <br /> coverage, decorative 3 mm glass bulb of these coatings for any given corro - <br /> , , <br /> type spray sprinklers designed for use sive environment. The effects of ambi- ° <br /> in light or ordinary hazard, commercial ent temperature, concentration of „,, <br /> ,,, <br /> occupancies such as banks, hotels, chemicals, and gas /chemical velocity, "”' - <br /> shopping malls, etc. should be considered, as a minimum, <br /> The recessed version of the Series along with the corrosive nature of the <br /> TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be <br /> ■ plicable, is intended for use in areas exposed. - '--- <br /> with a finished ceiling. It uses either a An intermediate level versions of the r <br /> two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers "fie <br /> Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet <br /> cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- i 3 <br /> recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 <br /> (19,1 mm) of total adjustment from the <br /> flush pendent position, or a two -piece WARNINGS <br /> Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY -FRB Sprinklers de- <br /> inch NPT) Recessed Escutcheon with scribed herein must be installed and ,.. j, ,, <br /> 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this <br /> ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- <br /> total adjustment from the flush pen- ble standards of the National Fire Pro - <br /> dent position. The adjustment pro- tection Association, in addition to the <br /> vided by the Recessed Escutcheon re- standards of any other authorities hav- <br /> duces the accuracy to which the fixed ing jurisdiction. Failure to do so may Model/Spriinkler <br /> pipe drops to the sprinklers must be impair the performance of these de- Identification <br /> cut. vices. <br /> Corrosion resistant coatings, where The owner is responsible for maintain- Numbers <br /> applicable, are utilized to extend the ing their fire protection system and de- <br /> life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 112 "NPT <br /> that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT <br /> manufacturer should be contacted TY2131 - Upright 4.2K, 1 /2"NPT <br /> IMPORTANT with any questions. TY2231 - Pendent 4.2K, 1/2 "NPT <br /> TY3131 - Upright 5.6K, 1/2 "NPT <br /> Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT <br /> Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT <br /> WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT <br /> with respect to handling and instal - TY4831- Upright 8.0K, 1/2 "NPT <br /> lation of sprinkler systems and com- TY4931- Pendent 8.0K, 1/2 "NPT <br /> ponents. Improper handling and in- <br /> stallation can permanently damage <br /> a sprinkler system or its compo- <br /> nents and cause the sprinkler to fail <br /> to operate in a fire situation or cause <br /> it to operate prematurely. <br /> Page 1 of 10 AUGUST, 2007 TFP171 <br />