My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9355
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9355
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 8:34:24 AM
Creation date
3/22/2011 8:30:24 AM
Metadata
Fields
Template:
Building Department
Company Name
NOM ZEPHYRHILLS LLC
Building Department - Doc Type
Permit
Permit #
09-9355
Building Department - Name
TIRE KINGDOM
Address
7540 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP161 Page 5 of 6 <br /> y 5/8±1/4" <br /> (15,9±6,4 mm) <br /> FACE OF RECESS <br /> MOUNTING SPRINKLER (END "A" USED FOR <br /> SURFACE / WRENCH <br /> 1/2" NPT MODELS) <br /> FITTING <br /> -74_ FIGURE 4 <br /> CLOSURE <br /> W -TYPE 6 SPRINKLER WRENCH <br /> ....161.. 2 -7/8" DIA. WRENCH <br /> (73,0 mm) <br /> SERIES RECESS <br /> TY-B I I 2-1/4" DIA. <br /> '. (57,2 mm) <br /> MOUNTING I AI II <br /> PLATE <br /> IH ._ <br /> PUSH WRENCH <br /> _�. 1 / 8 ' INTO ENSURE <br /> (3,2 mm) ENGAGEMENT <br /> WITH SPRINKLER <br /> 1 -1/4" (31,8 mm) _ 3/4" (19,1 mm) WRENCHING AREA <br /> 3/4" (19,1 mm) 1/4" (6,4 mm) <br /> FIGURE 5 <br /> FIGURE 3 W -TYPE 7 RECESSED <br /> SERIES TY -8 RECESSED HORIZONTAL SIDEWALL SPRINKLER SPRINKLER WRENCH <br /> WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT <br /> STYLE 10 RECESSED ESCUTCHEON <br /> Care and painted, plated, coated or otherwise corrosion resistant coating, as it may <br /> altered after leaving the factory. Modi- be affected by the corrosive conditions <br /> fied sprinklers must be replaced. present. <br /> Maintenance Sprinklers that have been exposed to <br /> corrosive products of combustion, but The owner is responsible for the in- <br /> The Series TY -B Sprinklers must be have not operated, should be replaced spection, testing, and maintenance of <br /> maintained and serviced in accord- if they cannot be completely cleaned their fire protection system and de- <br /> ance with the following instructions: by wiping the sprinkler with a cloth or vices in compliance with this docu- <br /> by brushing it with a soft bristle brush. ment, as well as with the applicable <br /> NOTES standards of the National Fire Protec- <br /> Before closing a fire protection system Care must be exercised to avoid dam tion Association (e.g., NFPA 25), in <br /> main control valve for maintenance age to the sprinklers - before, during, addition to the standards of any other <br /> work on the fire protection system that and after installation. Sprinklers dam- authorities having jurisdiction. The in- <br /> it controls, permission to shut down the aged by dropping, striking, wrench stalling contractor or sprinkler manu- <br /> affected fire protection system must be twist/slippage, or the like, must be re- facturer should be contacted relative <br /> obtained from the proper authorities placed. Also, replace any sprinkler that to any questions. <br /> and all personnel who maybe affected has a cracked bulb or that has lost <br /> by this action must be notified. liquid from its bulb. (Ref. Installation It is recommended that automatic <br /> Section). sprinkler systems be inspected, <br /> The owner must assure that the sprin- tested, and maintained by a qualified <br /> klers are not used for hanging of any Frequent visual inspections are rec- Inspection Service in accordance with <br /> objects; otherwise, non - operation in ommended to be initially performed for local requirements and /or national <br /> the event of a fire or inadvertent opera- corrosion resistant coated sprinklers, codes. <br /> tion may result. after the installation has been com- <br /> pleted, to verify the integrity of the cor- <br /> Absence of an escutcheon, which is rosion resistant coating. Thereafter, <br /> used to cover a clearance hole, may annual inspections per NFPA 25 <br /> delay the time to sprinkler operation 117 should suffice; however, instead of in- <br /> a fire situation. specting from the floor level, a random <br /> Sprinklers that are found to be leaking sampling of close -up visual inspec- <br /> or exhibiting visible signs of corrosion tions should be made, so as to better <br /> must be replaced. determine the exact sprinkler condi- <br /> tion and the long term integrity of the <br /> Automatic sprinklers must never be be <br />
The URL can be used to link to this page
Your browser does not support the video tag.