Drawing Number <br />ES -2 <br />02 of 09 <br />r n 1 „ <br />POWER SOURCE: OWNERS E.C. TO PROVIDE (1) 2 X 4 n X 2/8 STANDARD OUTLET BOX <br />1 u <br />POWER SOURCE: OWNERS r E.C. TO PROVIDE (1) 4 " X 4 u X 2/e STANDARD OUTLET BOX <br />DMP XR20 <br />(120 VAC, 60 HZ, 20 AMP UNSWITCHED) FOR SUPPLIED TRANSFORMER AS CLOSE TO <br />DIGITAL VIDEO RECORDER (DVR) WITH QUADRAPLEX RECEPTACLE (120 VAC, 60 HZ, 20 AMP UNSWITCHED) WITHIN 10' -0" <br />GENERAL NOTE <br />DMP XR40 <br />CABINET AS POSSIBLE. DISTANCE NOT TO EXCEED 50' -0" FROM CABINET. <br />OF UNIT. ALL RECEPTACLES MUST BE ON THE SAME POWER PHASE. <br />DMP XR500 <br />OWNER'S E.C. TO PROVIDE (2) 2" X 4" X 2' /s" STANDARD OUTLET BOXES FOR PERIPHERAL <br />E.C. TO PROVIDE (1) 6" X 6" X 4" MINIMUM SIZE PULL BOX FOR COLLECTION OF COAX <br />1. PER DIEBOLD SPECIFICATIONS AND THE NATIONAL ELECTRICAL CODE, PURCHASER MUST MAKE ALL WALL AND LINING <br />�'� <br />DEVICES AT 5Y ON CENTER 4' -3" ABOVE FINISHED FLOOR. <br />CABLES. <br />PENETRATIONS; INSTALL ALL CONDUIT, OUTLET BOXES, JUNCTION BOXES, JUNCTION BOX COVERS, 110 -120 VOLT 60 HZ <br />ELECTRICAL POWER WITH <br />P R 0 D U C l <br />MOUNT CABINET FROM REAR MOUNTING HOLES. <br />RS 232 LOCAL ACCESS, ETHERNET, AND /OR DIAL UP MODEM REQUIRED FOR RETRIEVAL <br />SEPARATE INSULATED GROUND WIRE; OBTAIN ALL PERMITS AND ALL LEASED WIRES INCLUDING <br />ENCLOSURE MODEL: 350-17 X 13'/2" X 3Y2" <br />TRANSMISSION. <br />TELEPHONE LINES FOR REMOTE CONNECTIONS; AND REMOVE AND /OR RELOCATE ANY FIXTURES OR OBSTACLES TO PERMIT <br />INSTALLATION <br />A P P 11 C A l 10 N <br />350- - 17'/2' X 13'/2' X 3 3 /a" <br />RACK MOUNT DVR AS PROVIDED. SOME DVR UNITS CAN BE WALL MOUNTED AS <br />OF DIEBOLD EQUIPMENT. IN THE EVENT OF A CONFLICT BETWEEN DIEBOLD SPECIFICATIONS AND LOCAL OR <br />341 - 12 X 016" X 2 %" <br />REQUIRED. <br />STATE LAWS OR THE NATIONAL ELECTRICAL CODE, LOCAL OR STATE LAWS OR THE NATIONAL ELECTRICAL CODE SHALL GOVERN. <br />S E R V 1 C E S <br />NOTE: OWNER'S E.C. TO PROVIDE COLD WATER PIPE EARTH GROUND. <br />DVR SIZE AND WEIGHT VARIES DEPENDING ON MANUFACTURER. WEIGHTS RANGE FROM <br />WHEN WIRING IS RUN IN HOLLOW SPACES SUCH AS ABOVE SUSPENDED CEILINGS AND SUCH HOLLOW SPACES ARE USED FOR <br />2. ENVIRONMENTAL AIR - HANDLING PURPOSES, THE WIRING MUST EITHER BE LISTED FOR SUCH PURPOSES <br />6 LBS TO 30 LBS. <br />OR BE INSTALLED IN <br />ELECTRICAL METALLIC TUBING, FLEXIBLE METALLIC TUBING, INTERMEDIATE METAL CONDUIT, RIGID METAL CONDUIT, METAL <br />❑ <br />KEYPAD <br />POWER SOURCE: 12 VDC FROM ALARM PANEL <br />POWER SOURCE: OWNER'S E.C. TO PROVIDE (1) 21/8" X 4" X 1 1/8" STANDARD OUTLET BOX <br />SURFACE RACEWAY OR WIREWAY WITH METAL COVERS WHERE ACCESSIBLE OR FLEXIBLE METAL CONDUIT. (SEE SECTION <br />CANTON OFFICE <br />E.C. TO PROVIDE (1) 4" X 4" X 21/8" STANDARD OUTLET BOX FOR MOUNTING. INSTALL <br />MONITOR (120 VAC, 60 HZ, 20 AMP, UNSWITCHED) WITHIN T -0" OF UNIT. <br />300 -22 (C) NATIONAL ELECTRICAL CODE). <br />OUTLET BOX CENTERED T -9" TO FINISHED FLOOR. (MEETS ADA REQUIREMENTS) <br />3. EXISTING ALARM AND CAMERA WIRING MUST BE REPLACED IF ANY OF THE FOLLOWING CONDITIONS EXIST <br />818 Mulber Road SE <br />TYPICALLY DESK MOUNTED, HOWEVER KITS CAN BE PURCHASED FOR ALTERNATE <br />Dept. E <br />POWER SOURCE: OWNER'S E.C. TO PROVIDE (1) 2" X 4" X 2'/8' STANDARD OUTLET BOX <br />INSTALLATIONS -WALL OR CEILING MOUNT. <br />B. THE EXISTING WIRING DOES NOT HAVE THERMAL PLASTIC INSULATION <br />Canton, OH 44707 <br />EXTENDED POWER SUPPLY <br />(120 VAC, 60 HZ, 20 AMP UNSWITCHED) FOR SUPPLIED TRANSFORMER AS CLOSE TO <br />SIZE AND WEIGHT VARIES BY MANUFACTURER. WEIGHT CAN BE 65 LBS OR MORE <br />C. THE EXISTING WIRING DOES NOT HAVE SUFFICIENT CONDUCTORS <br />(FOR 48 AND 80 HOURS) <br />CABINET AS POSSIBLE. DISTANCE SHOULD NOT EXCEED 50' -0" FROM CABINET. <br />D. THE EXISTING WIRING SIZE DOES NOT MEET DIEBOLD SPECIFICATIONS <br />MOUNT CABINET FROM REAR MOUNTING HOLES. <br />POWER SOURCE: 12 VDC OR 24 VAC PROVIDED BY THE VIDEO POWER SUPPLY. SPLIT <br />E. THE EXISTING CAMERA AND HOLD -UP DEVICE WIRING ARE RUN IN THE SAME SHIELDED CABLE BUNDLE <br />DALLAS OFFICE <br />ENCLOSURE MODEL: 350-17 X 13' X 3Y2" <br />CAMERA <br />CAMERA M -1 CABLE - COAX PORTION TO DVR AND (2) CONDUCTOR TO POWER SUPPLY. <br />*AN EXCEPTION TO THIS RULE MAY BE MADE PROVIDING THE EXISTING WIRING IS IN PROPERLY GROUNDED METALLIC CONDUIT, <br />350A - 17 X 133 '/z" X 3' /a" <br />OWNER'S E.C. TO PROVIDE (1) 2 GANG FLUSH MOUNTED OUTLET 80X BEHIND EACH <br />IS NO UNSHIELDED CAMERA WIRING IN THE SAME CONDUIT WITH ALARM WIRING AND THE WIRING MEETS ALL OTHER <br />1221 South Beltline Road <br />341 - 12 X 6 X 2%8' <br />CAMERA (RECOMMENDED HEIGHT) ABOVE FINISHED FLOOR. COVERPLATE <br />STANDARDS LISTED ABOVE. SHOULD REWIRING BE REQUIRED AT A LATER DATE TO PREVENT FALSE ALARMS WHICH ARE CAUSED <br />Suite 700 <br />WITH BUSHED O OPENING FOR THIS BOX. <br />BY DEFECTIVE WIRING OR RADIO FREQUENCY INTERFERENCE, SUCH REWIRING WILL BE THE RESPONSIBILITY OF THE PURCHASER. <br />Coppell, TX 75019 <br />APPROXIMATE WEIGHT: 28 LBS. <br />CEILING MOUNT: ABOVE FINISHED CEILING CLOSE TO MOUNTING BRACKET. <br />INTERIOR WALL MOUNT: CENTERED ABOVE WALL BRACKET. <br />4. ALL WIRING INCLUDING POWER, LOW VOLTAGE CONTROL AND VIDEO AS SPECIFIED: <br />MAXIMUM DISTANCE BETWEEN ANY CAMERA AND RECORDER IS 1000' WITH COAX CABLE. <br />MAXIMUM DISTANCE BETWEEN CAMERA AND POWER IS 350' WITH 22AWG. <br />E] <br />OWNER'S E.C. TO PROVIDE AND INSTALL (1) 4" X 4" X 2 JUNCTION BOX WITH COVER <br />SAFE & CHEST ALARM <br />AND TAMPER SWITCH BEHIND SAFE AND WITHIN 16" OF CONDUIT STUB OUT, RACK <br />EXTERIOR WALL MOUNT: WEATHER PROOF BOX(ES) ABOVE WALL BRACKET - (1) FOR <br />MAXIMUM DISTANCE BETWEEN CAMERA AND POWER IS 750' WITH 18AWG. <br />ORLANDO OFFICE <br />PROTECTION KIT <br />BOX OR NIPPLE (VERIFY CHEST MODEL). E.C. TO PROVIDE RIGID OR FLEX METAL <br />CAMERA WIRING, (1) FOR OPTIONAL HEATER POWER IF REQUIRED. MINIMUM OF 8' -6" TO <br />12' -0" ABOVE FINISHED GRADE. <br />ALL CABLE RUNS BETWEEN CAMERA AND RECORDER MUST BE "HOME RUN" WITH COAX CABLE. <br />43 Skyline Drive <br />CONDUIT FROM JUNCTION BOX TO STUB OUT, RACK BOX OR NIPPLE. <br />WHERE A RUN LONGER THAN 1000' IS NEEDED, VIDEO AMPLIFIERS ARE REQUIRED. <br />Suite 1051 <br />� <br />POWER SOURCE: OWNERS E.C. TO PROVIDE (1) 2/8 X 4 X 1 /e „ STANDARD OUTLET BOX <br />� <br />5. ALL CONDUIT ENTERING A VAULT WILL BE RESTRICTED TO 1 MAXIMUM AND SHALL HAVE TWO (2) 90 BENDS WITHIN THE VAULT <br />Lake Mary, FL 32746 <br />STEEL ENCASED: OWNER'S E.C. TO PROVIDE AND INSTALL (1) 1" DIAMETER CONDUIT <br />AFTER HOUR DEPOSITORY <br />FROM ALARM CONTROL PANEL TO 4" X 4" X 21/8' ALARM JUNCTION BOX (BY E.C.) <br />VIDEO POWER SUPPLY (120 VAC, 60 HZ, 20 AMP, UNSWITCHED) DUPLEX RECEPTACLE WITHIN 6 -0 " OF UNIT. <br />WALL STRUCTURE. ARRANGEMENT OF BENDS SHALL BE SO THAT DRAINAGE IS TO THE EXTERIOR OF THE VAULT. WHEN <br />PROTECTION KIT <br />MOUNTED IN AREA NEAR STEEL SHROUD OR ON TOP OF RECEIVING CHEST WITH <br />DEPENDING ON MANUFACTURER UNIT MAY BE EITHER RACK OR SURFACE MOUNTED. <br />PENETRATING AN EXISTING POURED IN PLACE VAULT, THE MAXIMUM HOLE SIZE IS 172 ". WHEN PENETRATING A MODULAR VAULT <br />❑ <br />ADAPTER FOR FLEX CONDUIT. <br />THE MAXIMUM HOLE SIZE IS 2" HOWEVER, MULTIPLE HOLES ARE PERMITTED AS LONG AS THEY ARE AT LEAST 7" APART. <br />RETAIL OFFICE <br />CONCRETE ENCASED: OWNER'S E.C. TO PROVIDE AND INSTALL (1) 1" DIAMETER <br />SIZE AND WEIGHT VARIES BY MANUFACTURER. WEIGHTS RANGE FROM 6 LBS. TO 20 LBS. <br />6. ONLY WIRE MEETING THE SPECIFICATIONS SET FORTH IN THE DIEBOLD ELECTRONIC SECURITY AND SURVEILLANCE CABLE <br />261 Cedar Hill Rd. <br />CONDUIT FROM ALARM CONTROL PANEL STUBBED OUT INTO AREA OF 6" REINFORCED <br />SCHEDULE (FILE NO. 170 -100) MAY BE USED. <br />Bldg. C -Ste. 8 -12 <br />CONCRETE WITH ADAPTER FOR FLEX CONDUIT. 1" DIAMETER CONDUIT ELBOW <br />7. WHEN BUILDING HAS EMERGENCY AND /OR STANDBY POWER SYSTEM, ALL BUILDING POWER REQUIRED FOR DIEBOLD EQUIPMENT <br />Marlborough, MA 01752 <br />WELDED TO SAFE WITH 1" DIAMETER FLEX CONDUIT AND ADAPTERS TO TERMINAL <br />SHALL BE CONNECTED TO THAT SYSTEM. <br />RACK BOX. TERMINAL RACK BOX (BY DIEBOLD), BUT INSTALLED BY OWNER' E.C. <br />8. SMOKE DETECT ORS ARE TO BE USED AS INTRUSION AND VANDALISM DETECTORS ONLY. THEY ARE NOT INTENDED FOR LIFE <br />SAFETY PROTECTION OR TO MEET LOCAL OR NATIONAL FIRE CODES. <br />THIS DRAWING I S THE PROPERTY OF DIEBOLD INCORPORATED <br />( c) COPYRIGHT2007 Diebold. Inc. All Rights Reserved <br />An unpublished Work. <br />ATM PROTECTION KIT <br />OWNER'S E.C. TO PROVIDE (1) 4" X 4" X 2%" JUNCTION BOX WITH COVER AND TAMPER <br />SWITCH ON HINGE SIDE OF ATM CHEST WITHIN 6-0" OF CONNECTION PLATE IN AN <br />9. MOUNTING HEIGHTS FOR RECEPTACLES PER STATE, LOCAL OR NATIONAL ELECTRICAL CODE. <br />ACCESSIBLE AREA. BOX CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR <br />10. SHELVES OR CABINET TO HOUSE VIDEO COMPONENTS BY OWNER. <br />This document is intended solely for the purpose of <br />providing information to aid in the preparation of a site for <br />NEW CONSTRUCTION OR SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING <br />3 <br />11. CAMERA RECEPTACLE REQUIREMENTS MAY BE REDUCED BY USING A 12 VDC POWER DISTRIBUTION MODULE (60 WATTS MAX, <br />he installation of Diebold equipment. It may include <br />CONSTRUCTION. OWNER'S E.C. TO RUN 3 /s" LIQUID TIGHT FLEX METAL CONDUIT OR /a" <br />r <br />2.5 AMPS) NOTE: EACH HAS TWO SETS OF TERMINAL BLOCKS FOR MULTIPLE CAMERA CONNECTIONS. <br />openings equipment specifications, clearances/service <br />areas electrical requirements and preferred installation <br />RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. <br />methods. Diebold Product Application Services (PAS) <br />TRANSACTION CAPTURE BY ETHERNET REQUIRES (1) CAT 5 CABLE FROM ATM TO <br />DIEBOLD INSTALLERS <br />designers are not licensed architects /engineers but may <br />offer recommendations relating to Diebold product <br />NETWORK CONNECTION. LOCAL TRANSACTION CAPTURE REQUIRES 1 <br />( ) C CABLE FROM <br />placement/installation. The customers architect is solely <br />ATM TO DVR. THERE WILL ALWAYS BE A CAT 5 REQUIRED, THE C CABLE IS ONLY NEEDED <br />responsible for final construction design, permitting or <br />IF TRANSACTION CAPTURE IS DONE LOCALLY. <br />12. LOCATION OF DEVICES AND CAMERAS ARE NOT TO INTERFERE WITH PARTITION WALLS, INTERIOR LIGHTING, SWITCHES ETC. <br />inspections required by local authorities for approval. <br />13. THE FOLLOWING WORK RELATED TO ELECTRONIC SECURITY EQUIPMENT WILL BE COMPLETED BY DIEBOLD INSTALLERS <br />OWNER'S E.C. TO PROVIDE (1) 2'/8' X 4" X 1 1/8' STANDARD JUNCTION BOX WITH COVER <br />...INSTALLATION AND ADJUSTMENT OF ALL DIEBOLD FURNISHED EQUIPMENT UNLESS OTHERWISE SPECIFIED <br />Revisions: <br />DOOR CONTACT <br />ABOVE CEILING, STUB CONDUIT INTO SECURE SIDE OF DOOR OPENING. RADIO <br />...CAMERA MOUNTING BRACKETS, AS WELL AS THE TESTING AND ADJUSTMENT OF CAMERAS AND ENTIRE SYSTEM AS REQUIRED <br />FREQUENCY DEVICE POWERED BY INTERNAL BATTERY. <br />...ACTUAL AIM OF CAMERAS AND PASSIVE INFRARED DEVICES. DEVICES SHOWN ON PLAN ARE FOR ILLUSTRATION PURPOSES <br />NOTE: MOUNT DOOR CONTACT OR WIRELESS TRANSMITTER 2" TO 5" FROM TOP EDGE <br />...MOUNTING AND CONNECTION OF ALL CAMERAS TO CABLES AND CONNECTION OF CABLES TO SYSTEM <br />OF SWING SIDE OF DOOR (OPPOSITE HINGE SIDE) <br />LOW VOLTAGE CABLE REQUIREMENTS <br />MOUNTING REQUIREMENT FOR SUSPENDED CEILING OR STEEL LINING: OWNER'S E.C. TO <br />SOUND DETECTOR INTERFACE <br />PROVIDE (1) 4" X 4" X 2'/8' JUNCTION BOX SURFACE MOUNTED ON VAULT CEILING PANEL <br />WITH RIGID OR FLEX METAL CONDUIT TO 2'/8" X 4" X 11%" JUNCTION BOX SURFACE <br />14. ALL WIRING SHALL BE TAGGED AT ALL JUNCTION POINTS AND SHALL TEST FREE FROM BREAKS, GROUNDS, SHORTS AND /OR <br />MOUNTED ON SUSPENDED CEILING. SOUND DETECTOR INTERFACE MOUNTS TO <br />CROSSES BETWEEN CONDUCTORS. DO NOT LABEL CONDUITS. <br />JUNCTION BOX ON SUSPENDED CEILING. <br />15. ALARM AND CAMERA WIRING CAN NOT BE RUN IN THE SAME CONDUIT WITH 120 VOLT AND ABOVE POWER WIRING, LOW VOLTAGE <br />ALTERNATE MOUNTING REQUIREMENT: SURFACE MOUNT SOUND DETECTOR INTERFACE <br />WIRING OF 30 VOLTS AND ABOVE OR TELEPHONE LINES. <br />TO VAULT CEILING PANEL. USE WIREMOLD TO RUN CABLES. <br />16. MINIMUM OF 2' -0" WIRE STUB -OUT AT ALL JUNCTION BOXES DESIGNATED FOR CONNECTION OF DEVICES, CABINETS, OR FOR <br />SPLICING, UNLESS OTHERWISE SPECIFIED. <br />MOUNTING REQUIREMENT FOR SUSPENDED CEILING OR STEEL LINING: OWNER'S E.C. <br />SOUND DETECTOR <br />TO PROVIDE (1) 2'/e" X 4" X 1 1/8" JUNCTION BOX FOR EACH SOUND DETECTOR, SURFACE <br />MOUNTED ON VAULT CEILING PANEL WITH RIGID OR FLEX METAL CONDUIT TO2Ya "X4" <br />OWNERS ELECTRICAL CONTRACTOR (E .C.) TO <br />X 1 Ye" JUNCTION BOX SURFACE MOUNTED ON SUSPENDED CEILING. SOUND DETECTOR <br />MOUNTS TO JUNCTION BOX ON SUSPENDED CEILING. <br />...PROVIDE ALL POWER. <br />ALTERNATE MOUNTING REQUIREMENT: SURFACE MOUNT SOUND DETECTOR TO VAULT <br />...PROVIDE ALL CONDUITS AND ELECTRICAL BOXES FOR ALARM AND VIDEO DEVICES. THEY ARE ALSO TO DETERMINE ACTUAL SIZE <br />CEILING PANEL. USE WIREMOLD TO RUN CABLES. <br />AND ROUTING OF CONDUIT TQ SUIT LOCAL CONDITIONS, AS WELL AS DETERMINE THE NEED FOR LARGER CONDUIT SIZES BASED <br />NOTE: SOUND DETECTOR ADD ON KIT REQUIRED FOR DEAD AIR SPACE WITH A <br />ON NATIONAL ELECTRICAL CODE STANDARDS. THE MINIMUM CONDUIT SIZE ALLOWED IS %" AND THE MAXIMUM CONDUIT SIZE <br />SUSPENDED CEILING. <br />ALLOWED IS 1 FOR ALARM CABLES. ALL CONDUIT RUNS SHALL HAVE SWEEPING BENDS AND ANY RUNS 1`FiAT MAY FORM A <br />WATER TRAP MUST BE PROVIDED WITH DRAINAGE HOLES. <br />Z <br />OWNER'S E.C. TO PROVIDE (1) 4" X 4" X 21/8' JUNCTION BOX WITH FLAT COVER ABOVE <br />...DETERMINE THE SIZE REQUIRED AND PROVIDE AND INSTALL A MAIN PULL BOX IN AN ACCESSIBLE AREA. CABLES FROM <br />VAULT DOOR PROTECTION KIT <br />DOOR HEADER PANEL. <br />DEVICES DO NOT TERMINATE AT THIS BOX THEY ARE PULLED THROUGH TO THE MAIN ALARM PANEL. <br />O <br />MODULAR VAULT: STUB OUT 1 /2" CONDUIT IN DOOR HEADER PANEL <br />...VERIFY ALL NATIONAL, STATE AND LOCAL CODES FOR MULTI -STORY BUILDING COMPLIANCE AND PROVIDE ALL NECESSARY <br />POURED VAULT: OWNER'S E.C. TO INSTALL A JUNCTION BOX FLUSH MOUNTED INSIDE <br />OPENINGS AND FILLS FOR FLOOR TO FLOOR WIRING TO MEET CODE, <br />VAULT ABOVE VAULT DOOR OPENING. CENTER OF BOX 4" TO LEFT OF CENTER OF VAULT <br />...PROVIDE PULL STRINGS FOR ALL CONDUIT RUNS. <br />DOOR OPENING AND 4" ABOVE VAULT DOOR OPENING HEADER. (2) %" METAL CONDUITS <br />...PROVIDE ENOUGH RECEPTACLES TO SUPPLY POWER TO THE MONITOR, SWITCHER, STEPDOWN TRANSFORMERS AND ONE <br />Q O <br />FROM JUNCTION BOX STUBBED OUT 1" THROUGH HEADER WITH STANDARD THREADS. <br />SPARE. ALL RECEPTACLES FOR VIDEO EQUIPMENT MUST BE ON THE SAME POWER PHASE. <br />...PROVIDE A 6" SQUARE JUNCTION BOX FOR VIDEO CABLES. <br />0 <br />' ; _J LL <br />INOVONICS FA401, FA404 POWER PROVIDED BY ALARM PANEL OR AUXILIARY POWER SUPPLY VIA KEYPAD BUS. <br />INOVONICS FA416, FA <br />MOUNTING RECOMMENDATIONS: WHEN POSSIBLE MOUNT RECEIVER CENTRAL TO <br />...PROVIDE ALL DEVICES LOCATED IN FIRE RATED AREAS WITH CONDUIT STUB -UPS AND PULL STRINGS TO EXTERIOR OF FIRE RATED <br />o <br />FREQUENCY AGILE (FA) NOT COMPATIBLE <br />TRANSMITTERS. MOUNT AWAY FROM LARGE METAL OBJECTS WHEN POSSIBLE. <br />AREA. <br />>.,. J <br />J <br />WITH ECHOSTREAM (EN) ALARM <br />PERFORMANCE WILL BE IMPAIRED IF MOUNTED ON A METAL SURFACE. <br />-J <br />DEVICES <br />UNIT CAN BE SCREW MOUNTED THROUGH HOLES IN CORNERS OF HOUSING BASE. <br />} <br />W o a <br />3!c N N <br />POWER PROVIDED BY ALARM PANEL OR AUXILIARY POWER SUPPLY. RADIO FREQUENCY <br />360 PASSIVE INFRARED <br />DEVICE POWERED BY INTERNAL BATTERY. <br />ti <br />FLUSH MOUNT: USE PROVIDED MOUNTING KIT <br />SURFACE MOUNT: UNIT CAN BE SCREW MOUNTED THROUGH HOLES IN BACK PLATE <br />NOTE: IF UNIT IS MOUNTED OUTSIDE OF RECOMMENDED HEIGHT RANGE OF 8' -0" TO 16'4" <br />Project No D22109 <br />SENSITIVITY WILL BE REDUCED. <br />Date 8 -25 -09 <br />POWER PROVIDED BY ALARM PANEL OR AUXILIARY POWER SUPPLY. RADIO <br />PASSIVE INFRARED <br />FREQUENCY DEVICE POWERED BY INTERNAL BATTERY. <br />'awn By VLW <br />FLUSH MOUNT: USE PROVIDED MOUNTING KIT <br />Requested ByDIANE ZABIK <br />SURFACE MOUNT: UNIT CAN BE SCREW MOUNTED THROUGH HOLES IN BACK PLATE <br />OPTIMAL MOUNTING HEIGHT VARIES BETWEEN 6-10" AND 8' -0" DEPENDING ON <br />Order No B# 687651 <br />MANUFACTURER. <br />Scale AS NOTED <br />POWER PROVIDED BY ALARM PANEL. <br />Sheet Title <br />ALARM LAMP SURFACE MOUNT ON VERTICAL WALL VISIBLE BY EMPLOYEES (KEEP SIGNAL AWAY <br />FROM PUBLIC VIEW). MOUNTING HEIGHT WILL VARY DEPENDING ON SITE CONDITIONS, <br />TYPICALLY 5' -0" ABOVE FINISHED FLOOR. <br />ELECTRONIC <br />SECURITY <br />SPECS /NOTES <br />Drawing Number <br />ES -2 <br />02 of 09 <br />