My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
09-9587
Zephyrhills
>
Building Department
>
Permits
>
2009
>
09-9587
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 9:26:45 AM
Creation date
3/22/2011 9:21:39 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LLC
Building Department - Doc Type
Permit
Permit #
09-9587
Building Department - Name
ZEPHYR LLC
Address
5939 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett@,fire.zephyrhills.fl.us <br /> Plan Review #: 09 -075 <br /> Project: Interior Modification <br /> Number of Pages: 3 <br /> September 28, 2009 <br /> I have received and reviewed the plans for the interior modification located at5939 Gall <br /> Blvd and will allow this to move forward under the following conditions listed below. <br /> Obtaining permit, the applicant acknowledges complying with the items listed below. <br /> Should anyone have any questions, please do not hesitate to contact the Fire Marshal's <br /> office. <br /> 1. Plans were reviewed with all applicable NFPA codes. Chapter 43 of NFPA <br /> 101 is the main section in which it determines the codes to use. Plans <br /> submitted do not show the space as it is currently and the usage for the space. <br /> In the south end of the unit there is a mezzanine that will actually be classified <br /> as a second story due to it covering more than 1/3 of that space. During a walk <br /> through it was stated that the space may be used as business/office area. That <br /> area needs to be shown in plans and labeled for use. If not used for office <br /> space then the building is treated as an assembly for the entire space. The rest <br /> of the space also needs to be shown how it is to be used; what area is actual <br /> gym equipment, what area is for aerobics /jazzercise, etc... This is needed to <br /> determine the correct occupant load, if over 300 persons, additional items <br /> would be required. <br /> 2. Construct an electrical room/closet that has a UL listed 1 hr rated assembly <br /> with a 1 hr rated door where multiple electrical panels are located. (NFPA <br /> 101, 8.7) <br /> 3. Certified fire extinguishers shall be installed in accordance of NFPA 10 for <br /> intended use and shall be located within 75' of travel distance. <br /> 4. Panic hardware shall be installed on all exit doors. <br /> 5. Change front exit light to combination exit/emergency light. <br /> 6. An assembly permit will need to be obtained by occupant. Permit may be <br /> obtained at the Building Department. <br /> 7. Ensure unit is addressed properly on main door and rear door. <br /> 8. Ensure rated walls (adjacent units) are sealed at roof deck and any <br /> penetrations are properly sealed to maintain the rating. <br /> 9. If A/C units are 2000 cfm's or more, duct detectors will be required with <br /> remote key switches to reset units. <br />
The URL can be used to link to this page
Your browser does not support the video tag.