TERMITE TREATMENT y PRE- FABRICATED WOOD TRUSSES <br />30 YEAR DIMENSIONAL PER HIB -91 AND FBC @ 24" O.C. <br />FIBERGLASS ROOF SHINGLES <br />SOIL CHEMICAL BARRIER METHOD OVER 15# BLDG. FELT. OVER <br />7/16" O.S.B. SHEATHING SECURED 12 <br />105,11 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION TO PRE - ENGINEERED TRUSSES PER SCHEMATIC <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. NAILING PATTERN ON DETAIL SHEET. 4 <br />1503.6 PROTECTION AGAINST DECAY AND TERMITES: CONDENSATE LINES AND ROOF DOWNSPOIUTS SHALL DISCHARGE AT LEAST 1 FOOT (305mm) DRIP EDGE <br />AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDER GROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. GUTTERS WITH <br />DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE ALUM., FASCIA GENERAL NOTES <br />END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. <br />R320.1 TERMITE PROTECTION: TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SUB FiASCIA — 1. THE DESIGN OF THIS STRUCTURE HAS BEEN REVIEWED FOR COMPLIANCE WITH THE <br />D DESIGN <br />PROVISIONS OF CHARIER 16 <br />SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A VENTED SIMPSON META 16 HURRICANE STRAP TH <br />PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. SEE SECTION 202, REGISTERED TERMITICIDE. UP014 COMPLETION OF THE APPLICATION OF ALUM. SOFFIT 12" WITH (7) lOdxl 1/2 NAILS AT EACH TRUSS END FLORIDA BUILDING CODE, 2007 EDITION <br />THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST O H ( (1,450 # MAX. ALLOWABLE DESIGN UPLIFT CAPACITY) (AND ALL 2009 UPDATES) USING THE FOLLOWING CRITERIA: <br />CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECIEVED A COMPLETE TREATMENT FOR THE PREVENTION <br />OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE <br />AND CONS " x 8" K .O. BLOK W/ (1) #5 ROD CONT, BASIC WIND SPEED = 120 MPH (3 SECOND GUST) <br />I <br />R320.1.1 IF SO IL T REATMENT sERV10ES, REATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, THE INITIAL CHEMICAL SOIL TREATMENT INSIDE THE I 8" x 8" CONCRETE BLOCK IMPORTANCE FACTOR = 1.0 ( BUILDING CATEGORY II ) <br />FOUNDATION PERIMETER SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING, AND COMPACTION IS COMPLETE. PRE -CAST CONC. EXPOSURE CATEGORY = B (ALL DIRECTIONS) <br />R320.1.2 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL SOIL SILL (THICK) i 8" x 8" "U" BLOCK W/ (1) #5 ROD CONT. INTERNAL PRESSURE COEFFICIENT = +/- 0.18 <br />TREATMENT SHALL BE RETREATED WITH ,4 CHEMICAL SOIL TREATMENT, INCLUDING SPACES BOXED OR FORMED. LINTEL PRECAST (OVER OPENINGS ONLY) I <br />R320.1.3 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SPACE IN CONCRETE FLOORS BOXED OUT OR FORMED FOR ED REINFORCED CELLS I ALL DOORS AND WINDOWS IN EXTERIOR WALLS SHALL HAVE A M INIMUM <br />GROUT <br />THE SUBSEQUENT INSTALLATION OF PLUMBING TRAPS, DRAINS, OR ANY OTHER PURPOSE SHALL BE CREATED BY USING PLASTIC OR METAL GROUTED <br />( I DESIGN WIND PRESSURE OF +/- 34.7 PSF UNLESS OTHERWISE NOTED. <br />PERMANENTLY PLACED FORMS OF SUFFICIENT DEPTH TO ELIMINATE ANY PLANNED SOIL DISTURBANCE AFTER INITIAL CHEMICAL SOIL TREATMENT. ( T D ROD ) o0 <br />R320.1.4 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED ALUM. SINGLE HUNG 'WINDO'W <br />TOP TO EMBED 6" MIN. INTO <br />WITH A MINIMUM 6 MILLIMETER VAPOR RETARDER TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE 'VAPOR RETARDER BOND BEAM W/ 90 deg. I °O 2. COMPONENTS AND CLADDING WIND PRESSURES TO BE USED FOR DESIGN OF EXTERIOR <br />PLACEMENT, RETREATMENT IS REQUIRED. ANY WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE AFTER CHEMICAL HOOK OVER BOND BM. REINF. COMPONENT AND CLADDING MATERIALS ARE AS FOLLOWS: <br />TREATMENT UNTIL THE CONCRETE FLOOR IS POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID PENETRATING OR DISTURBING TREATED SOIL. W ALLS: 8" HOLLOW <br />IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CONCRETE OVERPOUR OR MORTAR ACCUMULATED <br />ALONG THE EXTERIOR FOUNDATION PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR CHEMICAL SOIL TREATMENT, TO ENHANCE VERTICAL C.M.U. (RUNNING BOND) EFFECTIVE WIND AREA WALLS /WINDOWS ROOFS <br />PENETRATION OF THE CHEMICALS. I CLEANOUT OPENING 4 " x 4" UP TO 10 S.F. 34,7 PSF 50,1 PSF <br />R320.1.6 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION, CHEMICAL SOIL TREATMENTS SHALL ALSO BE APPLIED STRUCK BLOCK FINISH EACH GROUTED CELL UP TO 20 S.F. 32.4 PSF 45.4 PSF <br />UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1 FOOT (305mrn) OF THE PRIMARY STRUCTURE SIDEWALLS, ALSO, A VERTICAL CHEMICAL I) OV TO 50 S.F. 29.3 PSF 39.3 PSF <br />BARRIER SHALL BE APPLIED PROPTLY AFTER CONSTRUCTION IS COMPLETED, INCLUDING INITIAL LANDSCAPING AND IRRIGATION /SPRINKLER OVE 50 S.F. 26 PSF <br />INSTALLATION. ANY SOIL DISTURBED AFTER THE CHEMICAL 'VERTICAL BARRIER IS APPLIED SHALL BE PROPTLY RETREATED. II 4" MONOLITHIC CONCRETE SLAB (3000 psi) , 34,7 PSF <br />R320.1.7 IF A REGISTERED TERMITICIDE FORMULATED AND REGISTERED AS A BAIT SYSTEM IS USED FOR SUBTERRANEAN TERMITE PREVENTION, W ITH 6x6 10/10 W.W.M. OR FIBER REINF,OV R <br />SECTIONS R320.1.1 THROUGH R320.1.6 DO NOT APPLY; HOWEVER A SIGNED CONTRACT ASSURING THE INSTALLATION, MAINTENANCE AND DOWELS: (1) #5 WHERE I COMPACTED FILL TERMITE TREATED 3. UNLESS OTHERWISE SPECIFIED, ALL WORK AND MATERIALS SHALL CONFORM TO THE <br />MONITORING OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS FROM THE ISSUE OF THE CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED SHOWN ON PLAN EMBED <br />TO THE BUILDING OFFICIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. 12 MIN. INTO FOOTING GRADE a ;-7L, -7 - ��-? -y ..� _ _ REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC). <br />IF THE BAITING SYSTEM DIRECTIONS FOR USE REQUIRE A MONITORING PHASE PRIOR TO INSTALLATION OF THE PESTICIDE ACTIVE INGREDIENT, W/ 90 deg HOOK - �i . � • 1 -1 MIN. COVER 4. DESIGN LIVE LOAD <br />THE INSTALLATION OF THE MONITORING PHASE COMPONENTS SHALL BE DEEMED TO CONSTITUTE INSTALLATION OF THE SYSTEM. S USED IN THE ANALYSIS ARE FOLLOWS: <br />R320.1.8 IF A REGISTERED TERMITICIDE FORMULATED AND REGISTERED AS A WOOD TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION. �, 6 MIL VAPOR BARRIER ROOFS — 30 PSF <br />SECTIONS R320.1.1 THROUGH R320.1.6 DO NOT APPLY. APPLICATION OF THE WOOD TREATMENT TERMITICIDE SHALL BE AS REQUIRED BY LABEL 4:�•,� — <br />DIRECTIONS FOR USE, AND MUST BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. NOTE: ANY LAPS BETWEEN VERT FLOORS = 40 PSF <br />R320.2 PENETRATION: PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF STEEL AND DOWELS OR BETWEEN (NON- ELEVATED FLOORS <br />MONOLITHIC FOOTING ) <br />CELLULOSECONTAINING MATERIALS AND, IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PROTECTION, SHALL RECIEVE APPLICATION W/ (2) IT BARS CO T. 16" VERTICAL WALL STEEL SHALL BE PORCHES, LOFTS, BALCONIES = 60 PSF <br />OF A TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. MIN. 40 BAR DIAMETERS <br />5. CONCRETE FOUNDATIONS SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 18, <br />FBC, WHERE SUBSURFACE GEOTECHNICAL INVESTIGATIONS ARE NOT PROVIDED TO <br />TYPICAL WALL TO THE ENGINEER, FOUNDATIONS AND FOOTINGS ARE DESIGNED FOR THE FOLLOWING <br />SECTION ASSUMED SOIL BEARING <br />CONDITIONS: LOOSE GRANULAR MATERIAL WITH NO <br />APPRECIABLE CLAY OR ORGANIC MATERIAL WITH A MINIMUM ALLOWABLE BEARING <br />PRESSURE OF 2000 PSF. COMPACT FILL TO 95% MODIFIED PROCTOR. <br />6. MASONRY CONSTRUCTION SHALL CONFORM TO REQUIREMENTS OF CHAPTER 21, FBC. <br />NET AREA COMPRESSIVE STRENGTH OF MASONRY IS 1500 PSI. TYPE M OR S MORTAR <br />SHA' L BE USED. ALL MASONRY SHALL BE LAID IN RUNNING BOND PATTERN, <br />OVERHEAD SECTIONAL DOOR 7. GROUT USED TO FILL CELLS, LINTELS AND BOND BEAMS SHALL CONFORM TO <br />1/2" x 8" A.B. 'W/ <br />FILLED CELL Wi 0 TRACK W1 3/16" x 1" STEEL REQUIREMENTS OF CHAPTER 21, FBC. REQURED MINIMUM COMPRESSIVE STRENGTH IS <br />(1) 45 VERT. (5) 112" DIA. x 6" 2" WASHERS SET _ LAG BOLT W/ WASHER MIN. 2500 PSI AT 28 DAYS. LED <br />ADD #5 CORNER 1- BOLTS CELL. MIN PER JAMB o (6) PER TRACK TO JAMB <br />BAR BENT 24" <br />8. REINFORCING BARS SHALL BE GRADE 40 DEFORMED BILLET STEEL BARS AND COMPLY <br />BOND BEAM BAR 0 24" CONT. W000 TRIM WITH ASTM A 615 REQUIREMENTS. JOINT REINFORCING IF USED, SHALL BE 9 GAGE, <br />- <br />o <br />P.T. #2 SYP GALVANIZED STEEL CONFORMING TO ASTM A 82 REQUIREMENTS. WELDED WIRE <br />•' �:` <br />#5 BAR VERT. 2" X 6° Q FABRIC SHALL CONFORM TO ASTM A 185 REQUIREMENTS. WIRE FABRIC SHALL BE <br />W/ STD. HOOK _ " O SECTIONAL SUPPORTED AS REQUIRED IN SECTION R506, FBC. SYNTHETIC FIBER REINFORCEMENT <br />AT TOP OVERHEAD DR. IS NOT PERMITTED AS A SUBSTITUTE FOR WIRE FABRIC UNLESS IT IS SHOWN ON THE <br />GROUTED CELL 2x6 P.T. DRAWINGS. <br />AT CORNER WD. JAMB p <br />DOOR AND CONNECTION <br />PER GARAGE DOOR MANUF. `r 9. CONCRETE SHALL CONFORM TO REQUIREMENTS OF CHAPTER 19, FBC, AND HAVE A <br />TYP. GARAGE DOOR O MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. <br />TYPICAL BOND _ G ARAGE SLAB <br />00 Sll/ <br />G ARAGE TRACK MOUNT 10. ROOF AND WALL SHEATHING SHALL BE APA -RATED PANELS AND CONFORM TO <br />BEAM CORNER REQUIREMENTS OF CHAPTER 23, FBC. WOOD STRUCTURAL PANEL DIAPHRAGM NAIL <br />SPACING ALONG PANEL EDGES SHALL BE 6" O.C. UNLESS NOTED OTHERWISE. INTER- <br />OVRHEAD GARAGE <br />MEDIATE FASTENERS SHALL BE AT 6" O.C. UNLESS NOTED OTHERWISE. FASTENERS <br />SHALL BE 8d RING SHANK NAILS, NO SUBSTITUTIONS. THICKNESS OF WOOD PANELS <br />DOOR DETAIL ARE NOTED ON THE PLANS, MINIMUM NOMINAL PANEL THICKNESS SHALL BE 7/16 ". <br />11. WOOD STUDS AND GIRDER SUPPORT POSTS USED FOR BEARING WALL FRAMING OF <br />LESS THAN 10' PLATE HEIGHT SHALL BE HEM -FIR, S -P -F; OR S -Y -P, STUD GRADE OR <br />BETTER. WOOD STUDS AND GIRDER SUPPORT POSTS USED FOR BEARING WALL <br />NOTE: FOR ANY UPRIGHT 48" AND GREATER <br />ON GABLE END, FASTEN 2X4 #2 GRADE ON SIDE FRAMING WITH 10' PLATE HEIGHT AND HIGHER SHALL BE HEM -FIR, S -P -F; OR, S -Y -P <br />FROM TOP TO BOTTOM CHORD OF TRUSS 2X6 EAVE TRIM CONSTRUCTION GRADE OR BETTER. WALL OPENINGS SHALL BE CONSTRUCTED IN <br />ACCORDANCE WITH CHAPTER 23, SECTION 2308, FBC, UNLESS OTHERWISE NOTED ON <br />Z S7MOOOTH 2 O -GROVE CEMENT BOARD SIDING THE PLANS. <br />\ OVER HOUSE 'WRAP <br />OVER 7/16" O.S.B. SHEATHING <br />10 BLOCKING 'W/ 8d COMMON NAILS Q G" O.C. 12. WOOD BEAMS, RAFTERS AND OTHER HORIZONTAL LOAD BEARING ELEMENTS SHALL <br />48" O.C. BE S -Y -P #2 GRADE OR BETTER. <br />(GABLE ENDS ONLY). <br />� � I <br />DIAGONAL BRACING @ 13. FASTENING OF WOOD FRAMING SHALL CONFORM TO TABLE 2304.9.1, FBC, UNLESS <br />\�� I 8' -0" O.C. MAX. W /(4)16d EA END <br />,� I OTHERWISE NOTED. <br />PRE -ENG. TYP �;< 2X BLOCKING <br />ROOF TRUSSES 2x4 ; GABLE TRUSS 14. DESIGN OF PREFABRICATED WOOD TRUSSES IN FLOORS AND ROOFS IS DELEGATED TO <br />THE TRUSS MANUFACTURER'S ENGINEER. THE TRUSS ENGINEER SHALL SUBMIT <br />2x4 i' P.T. 2X6 PLATE <br />ENGINEERING DOCUMENTS FOR REVIEW FOR CONFORMANCE WITH THE DESIGN <br />USE IOD FLAT ; INTENT OF THE PROJECT. <br />NAILS RUNNER I P2-12d NAILS <br />' 15. INSTALLATION OF PREFABRICATED WOOD TRUSSES SHALL FOLLOW THE <br />/2" X 6" ANCHOR BOLTS RECOMMENDATIONS OF THE TRUSS PLATE INSTITUTE PUBLICATION HIB -91, AND THE <br />W12" DIAM, WASHER 4' -0" O.C. MANUFACTURER'S INSTRUCTIONS. THE CONTRACTOR IS RESPONSIBLE FOR <br />11.4 @ <br />' INSTALLING ALL TEMPORARY AND PERMANENT TRUSS BRACING IN ADDITION TO ANY <br />2X4 BLOCKING SUPPLEMENTAL BRACING SHOWN ON THE DRAWINGS. <br />LAYED HORIZONTAL 2X4 BLOCKING <br />(3 BAYS) @48" O.C. 12d NAILS @ 8" O.C. <br />FIRST 2 TRUSS BAYS 16. WOOD CONSTRUCTION CONNECTORS SHOWN ON THE PLANS REPRESENT THE _ \ C NOTE: ALL 'WOOD TO BE NUMBER 2 GRADE CONC. FILLED "U" BLOCK DESIGNER'S INTENT TO FURNISH A COMPLETE LOAD PATH FROM ROOF TO <br />W/ 1 - #5 REBAR CONT. FOUNDATION. OTHER BRANDS OR TYPES OF CONNECTORS THAT HAVE DOCUMENTED <br />EQUIVALENT CAPACITY MAY BE SUBSTITUTED AT THE CONTRACTOR'S OPTION. <br />GABLE END BLOCKING DETAI L 8x8xl6 CMU WALL <br />NOTE: <br />PROVIDE APPROVED HORIZONTAL CORROSION - <br />RESISTANT FLASHING AT MASONRY /FRAME <br />• INTERSECTION (PER R703.8). <br />KELLY E. LYONS, P.E. <br />E # 9 33,33 <br />EB# 93;s3 <br />- --ff <br />DATE <br />THE STRUCTURAL SYSTEM FOR <br />THIS BUILDING HAS BEEN DESIGNED <br />TO COMPLY WITH APPLICABLE <br />WINDLOADING REQUIREMENTS OF <br />ASCE 7 -05 AND THE FLORIDA <br />BUILDING AND RESIDENTIAL CODE <br />2007 EDITION AND ALL 2009 <br />UPDATES, NO OTHER CERTIFICATION <br />IS EXPRESSED OR IMPLIED. THIS <br />CERTIFICATION IS NOT VALID <br />UNLESS IT CONTAINS AN ORIGINAL <br />SIGNATURE AND EMBOSSED SEAL, <br />I HAVE ALSO REVIEWED THE TRUSS <br />DRAWINGS PREPARED BY <br />41 TRUSS, SPRING HILL, FLORIDA <br />DATED SEPT. 22, 2009, JOB No. 50203 <br />FOR THIS PROJECT AND THEY ARE IN <br />CONFORMANCE WITH THESE <br />CONSTRUCTION DRAWINGS, <br />ALLTECH STRUCTURAL ENGINEERING, Inc. <br />2121 Scores <br />Tompa, Florida 33618 <br />Fax: (813) 247 -7409 <br />Phone: (813) 247 -7400 <br />1 09.25 -09 1 PRELIMINARY PLANS <br />09.28.09 REVISED PER CLIENT REVIEW <br />09.29 -09 FINAL PLANS - ENGINEER <br />DATE FILE N o. <br />EPT. 3638 <br />J.I.S. DESIGNS, Inc. <br />PF SI Of- NI IA L F3U ILUI NC OF S It. NFP, <br />5389 EAST GRANGER STREET <br />INVERNESS, FLORIDA, 34452 <br />352 - 637 -6971 <br />SHEET NUMBER <br />2 of <br />■ <br />Za <br />• <br />u <br />0 <br />M <br />�ti <br />W <br />C <br />.: <br />« <br />o <br />J <br />0 <br />ED <br />a- <br />• <br />A <br />` <br />-T- <br />U <br />o <br />W� <br />J <br />••1 <br />N <br />rA W. <br />W Cl) <br />� z tit <br />� <br />N <br />• <br />_ <br />D <br />DATE FILE N o. <br />EPT. 3638 <br />J.I.S. DESIGNS, Inc. <br />PF SI Of- NI IA L F3U ILUI NC OF S It. NFP, <br />5389 EAST GRANGER STREET <br />INVERNESS, FLORIDA, 34452 <br />352 - 637 -6971 <br />SHEET NUMBER <br />2 of <br />■ <br />• <br />• <br />••1 <br />• <br />_ <br />1 <br />• <br />• <br />• <br />DATE FILE N o. <br />EPT. 3638 <br />J.I.S. DESIGNS, Inc. <br />PF SI Of- NI IA L F3U ILUI NC OF S It. NFP, <br />5389 EAST GRANGER STREET <br />INVERNESS, FLORIDA, 34452 <br />352 - 637 -6971 <br />SHEET NUMBER <br />2 of <br />