Laserfiche WebLink
COMPATIBLE ANNUNCIATORS NZM -100: Similar to NMM -100, but may monitor up to 20 con - <br /> N- ANN- 80( -W): LCD Annunciator is a remote LCD annuncia- ventional two -wire detectors. Requires resettable 24 VDC <br /> tor that mimics the information displayed on the FACP LCD power. Consult factory for compatible smoke detectors. <br /> display. Recommended wire type is un- shielded. (Basic model NC -100: Addressable Control Module for one Style Y/Z (Class <br /> is black; order -W version for white; see DN 7114.) B /A) zone of supervised polarized Notification Appliances. <br /> N- ANN -LED: Annunciator Module provides three LEDs for Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification <br /> each zone: Alarm, Trouble and Supervisory. Ships with red or Appliance Circuit option requires external 24 VDC to power <br /> black enclosure (see DN- 60242). notification appliances. <br /> N- ANN -RLED: Provides alarm (red) indicators for up to 30 NC -100R: Addressable relay module containing two isolated <br /> input zones or addressable points. (See DN- 60242). sets of Form -C contacts, which operate as a DPDT switch. <br /> N- ANN -RLY: Relay Module, which can be mounted inside the Mounts directly to a 4.0" (10.16 cm.) box, surface mount using <br /> cabinet, provides 10 programmable Form -C relays. (See DN the SMB500. <br /> 7107.) NOT BG12LX: Addressable manual pull station with interface <br /> N- ANN -S /PG: Serial /Parallel Printer Gateway module <br /> pro—module mounted inside. <br /> vides a connection for a serial or parallel printer. (See DN N100 -ISO: Fault Isolator Module. This module isolates the <br /> 7103.) SLC loop from short circuit conditions (required for Style 6 or 7 <br /> N- ANN -I /O: LED Driver Module provides connections to a operation). <br /> user supplied graphic annunciator. (See DN 7105.) SMB500: Used to mount all modules except the NMM -100P. <br /> ACM -8R: Relay module provides 8 Form -C 5.0 amp relays. NMM- 100 -10: Ten -input monitor module. Mount one or two <br /> modules in a BB -XP cabinet (optional). Mount up to six mod - <br /> ACM Annunciator Series: LED -type fire annunciators capa- <br /> ble of providing up to 99 software zones of annunciation. Avail- ules on a CHS-6 chassis in a BB 25. <br /> able in increments of 16 or 32 points to meet a variety of NZM - 100-6: Six -zone interface module for compatible conven- <br /> applications. tional two -wire detectors. Mount one or two modules in a BB- <br /> LDM Graphic Series: Lamp Driver Module series for use with XP cabinet (optional). Mount up to six modules on a CHS -6 <br /> chassis in a BB-25. <br /> custom graphic annunciators. <br /> FDU 80 (Liquid Crystal Display) NOTE: For more information on Compatible Addressable Devices <br /> ( q Y p y) point annunciator: for use with the FireWarden -100 -2 Rev 2, see the following data <br /> 80 - character, backlit LCD - type fire annunciators capable of sheets (document numbers): N100 -ISO (DN- 6994), NP -100 series <br /> displaying English language text. (DN- 6995), NI -100 (DN- 6996), NH -100 series (DN- 6997), ND -100 <br /> NOTE: For more information on Compatible Annunciators for use series (DN- 7006), NP -A100 (DN- 6998), NMM- 100/NMM -100P/ <br /> with the FireWarden -100 -2 Rev 2, see the following data sheets NDM- 100MZM 100 (DN- 6999), NC 100 /NC -100R (DN- 7000), <br /> (document numbers) ACM -8R (DN- 3558), ACS /ACM Series (DN- NOT- BGI2LX (DN- 7001), NMM- 100 10 (DN- 6990), and NZM -100- <br /> 0524), LDM Series (DN- 0551), FDU -80 (DN- 6820). 6 (DN- 60150). <br /> COMPATIBLE ADDRESSABLE DEVICES Wiring Requirements <br /> All feature a polling LED and rotary switches for addressing. While shielded wire is not required, it is recommended that all <br /> NI -100: Addressable low- profile ionization smoke detector. SLC wiring be twisted -pair to minimize the effects of electrical <br /> NP -100: Addressable low- profile photoelectric smoke detector. interference. Wire size should be no smaller than 18 AWG <br /> NP -100T: Addressable low- profile photoelectric smoke detec- siize8dependsnonnthe larger than 12 length of the circuit Refer to <br /> tor with thermal sensor. panel manual for wiring details. <br /> NH -100: Fast - response, low- profile heat detector. <br /> NH -100R: Fast - response, low- profile heat detector with rate - <br /> of -rise option. <br /> NH -100H: Fixed high - temperature detector that activates at <br /> 190F/88C. <br /> NP- A100(A): Addressable low- profile multi- sensor detector. <br /> ND -100: Photoelectric low -flow duct smoke detector. <br /> DNR(A): Innovair Flex low -flow non -relay duct - detector hous- <br /> ing. (Order NP -100 separately.) <br /> DNRW: Innovair Flex low -flow non -relay duct - detector hous- <br /> ing, with NEMA -4 rating. Watertight. (Order NP -100 sepa- <br /> rately.) <br /> NMM -100: Addressable Monitor Module for one zone of nor- <br /> mally -open dry- contact initiating devices. Mounts in standard <br /> 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of- <br /> line resistor. Module may be configured for either a Style B <br /> (Class B) or Style D (Class A) IDC. <br /> NDM -100: Dual Monitor Module. Same as NMM -100 except it <br /> provides two Style B (Class B) only IDCs. <br /> NMM -100P: Miniature version of NMM -100. Excludes LED <br /> and Style D option. Connects with wire pigtails. May mount in <br /> device backbox. <br /> DN- 60417:C • 12/17/2009 — Page 3 of 6 <br />