My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10030
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10030
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:00:57 AM
Creation date
3/22/2011 10:56:53 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYRHILLS FIRE DEPARTMENT
Building Department - Doc Type
Permit
Permit #
10-10030
Building Department - Name
ZEPHYRHILLS FIRE DEPARTMENT
Address
38410 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire .Rescue <br /> 6907 Dairy Road. Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett (a),fire.zephyrhills.flus <br /> Plan Review #: I 0 -004 <br /> Project: Fire Alarm system <br /> Number of Pages: 1 plus packet w /calcs <br /> January 20, 2010 <br /> I have received and reviewed the plans for the installation of a fire alarm system located <br /> at 38410 6 Avenue and will allow the project to move forward. Please note that this <br /> review does not eliminate any further requirements as the project continues moving <br /> forward. By receiving permit, contractor acknowledges to comply with the items listed <br /> below. Should anyone have any questions, please do not hesitate to contact the Fire <br /> Marshal's office. <br /> 1. Installation shall be the latest edition of NFPA 72. <br /> 2. Remove device #C2 -6, C2 -7, and M014 but still run wire to that location. <br /> Leave at ceiling. <br /> 3. Remove device M004. <br /> 4. Add ceiling mount strobe/horn in between generator and pump room. <br /> 5. Add smoke detectors in generator and pump rooms. <br /> Inspections Required: <br /> 1. Acceptance Test <br /> 44/- A <br /> :4 <br /> KERRY BAR TT, FIRE MARSHAL <br /> ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.