10-10179
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10179
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:31:21 AM
Creation date
3/22/2011 11:27:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SOUTHSIDE CHURCH OF CHRIST
Building Department - Doc Type
Permit
Permit #
10-10179
Building Department - Name
SOUTHSIDE CHURCH OF CHRIST
Address
37737 C AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Smoke Detector Specifications <br /> Architectural /Engineering Specifications <br /> Smoke detector shall be a System Sensor i Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The <br /> detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric./thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135 °F <br /> (57.2 °C).The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster <br /> ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre- wiring of the <br /> base and the head shall be a plug -in type.The detector shall have a nominal sensitivity of 2.5 percent- per -foot nominal as measured in the UL smoke box.The <br /> detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual - <br /> color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used <br /> in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel <br /> and shall provide a loop testing capability to verify the circuit without testing each detector individually. <br /> Electrical Specifications <br /> • <br /> Operating Voltage Nominal: 12/24 V non - polarized <br /> Minimum: 8.5 V <br /> Maximum: 35 V <br /> Maximum Ripple Voltage 30% peak to peak of applied voltage <br /> Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average <br /> Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12 V, 23 mA @ 24 V <br /> Peak Standby Current 2-wire: 100 NA; 4 -wire: n/a <br /> Alarm Contact Ratings 2 -wire: n/a; 4 -wire: 0.5 A @ 30 V AC/DC <br /> Physical Specifications <br /> Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height <br /> Weight 6.3 oz (178 g) <br /> Operating Temperature Range 2W -B and 4W -B: 32 °F to 120 °F (0 °C to 49 °C); 2WT-B and 4WT-B: 32°F to 100 °F (0°C to 37.8 °C) <br /> Operating Humidity Range 0 to 95% RH non - condensing <br /> Thermal Sensor 135 °F (57.2 °C) fixed <br /> Freeze Trouble 2WT -B and 4WT-B only. 41°F (5 °C) <br /> Sensitivity 2.596/ft nominal <br /> Input Terminals 14 to 22 AWG <br /> Mounting 31/2-inch octagonal back box <br /> 4-inch octagonal back box <br /> Single -gang back box <br /> 4-inch square back box with a plaster ring <br /> Direct mount to ceiling <br /> LED Modes Power -Up Sequence for LED Indication <br /> LED Mode Green LED Red LED Condition Duration <br /> Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds <br /> Normal (standby) Blink every 5 seconds off <br /> Out of sensitivity off Blink every 5 seconds <br /> Freeze trouble off Blink every 10 seconds <br /> Alarm off Solid <br /> Ordering Information <br /> Model Thermal Wiring Alarm Current <br /> 2W -B No 2 -wire 130 mA max. limited by control panel <br /> 2WT-B Yes 2 -wire 130 mA max. limited by control panel <br /> 4W -B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V <br /> 4WT-B Yes 4 -wire 20mA @12V,23mA @24V <br /> Accessories <br /> 2W -MOD2 2 -wire loop test / maintenance module RT Removal / replacement tool <br /> SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter <br /> SYSTEM 02009 System Sen.,. <br /> 3825 Ohio Avenue • St. Charles, IL 60174 Product specifiononssubectto change without noticeVke systemsensaccom for <br /> SENSOR' Phone: 800- SENSOR2 • Fax: 630-377-6495 current product ffamatia' including the latest version of this data sheet. <br /> A05 -0318-007.6/09.12169 <br />
The URL can be used to link to this page
Your browser does not support the video tag.