My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10179
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10179
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:31:21 AM
Creation date
3/22/2011 11:27:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SOUTHSIDE CHURCH OF CHRIST
Building Department - Doc Type
Permit
Permit #
10-10179
Building Department - Name
SOUTHSIDE CHURCH OF CHRIST
Address
37737 C AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> SpectrAlert Advance Specifications <br /> Architect /Engineer Specifications <br /> General <br /> SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1 -inch back box, 4 -inch octagon back box, or double -gang back <br /> box.Two -wire products shall also mount to a single -gang 2 x 4 x 1' /s -inch back box. A universal mounting plate shall be used for mounting ceiling and <br /> wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with <br /> the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. <br /> When used with the Sync•Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24 -volt -rated notification <br /> appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit <br /> from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, <br /> 75, 95, 110, 115, 135, 150, 177, and 185. <br /> Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be <br /> wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at <br /> 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. <br /> Horn Strobe Combination <br /> The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The <br /> horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling <br /> appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector <br /> system.The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These <br /> options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models <br /> shall operate on a coded or non -coded power supply. <br /> Synchronization Module <br /> The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize <br /> SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a <br /> single pair of wires.The module shall mount to a 4 x 4 x 2 -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z <br /> (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they <br /> control.The module shall not operate on a coded power supply. <br /> Physical /Electrical Specifications <br /> Standard Operating Temperature 32 °F to 120 °F (0 °C to 49°C) <br /> Humidity Range 10 to 93% non - condensing <br /> Strobe Flash Rate 1 flash per second <br /> Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' <br /> Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) <br /> Input Terminal Wire Gauge 12 to 18 AWG <br /> Ceiling -Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) <br /> Wall -Mount Dimensions (including lens) 5.6 L x 4.7 - W x 2.5 D (142 mm L x 119 mm W x 64 mm D) <br /> Hom Dimensions 5.6 4.7 W x 1.3 mm Tx 119 mm W x 33 mm D) <br /> Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 L x 5.0 x 2.2 D (151 mm L x 128 mm W x 56 mm D) <br /> Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1 diameter x 2.2 high (180 mm diameter x 57 mm high) <br /> Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -H5) 5.7 L x 4.8 - W x 0.35 - D (145 mm L x 122 mm W x 9 mm D) <br /> Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6.9 diameter x 035 high (175 mm diameter x 9 mm high) <br /> Notes: <br /> 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. <br /> 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. <br /> A05- 0395-007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.