My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10179
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10179
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2011 11:31:21 AM
Creation date
3/22/2011 11:27:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SOUTHSIDE CHURCH OF CHRIST
Building Department - Doc Type
Permit
Permit #
10-10179
Building Department - Name
SOUTHSIDE CHURCH OF CHRIST
Address
37737 C AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications, Duct Smoke Detector Accessories <br /> APA151 Piezo Annunciator RTS151 Remote Test Station <br /> Voltage Regulated 24VDC Power Requirements Alarm LED: 2.8 to 32VDC,12 mA max. <br /> Operating Voltage 16 to 33 VDC Total Current: 105 mA max. <br /> Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC <br /> Temperature Range 0 °C to 49°C (32 °F to 120 °F) Reset Switch 10 VA @ 32 VDC <br /> Relative Humidity 10 to 93% non-condensing Alarm Response Time 40 seconds max. <br /> Wire Gauge 12 to 18 AWG Temperature Range —10 °C to 60°C (14 °F to 140 °F) <br /> Dimensions 4.6"H x 2.9 "W x .45" D Relative Humidity 9596 non- condensing <br /> MHR /MHW SpectrAlert Advance Mini -Horns Wire Gauge 14to 18 AWG <br /> Voltage Regulated 12 DC or FWR (Full Wave Rectified) Dimensions 4.8" H x 2.90"W x 1.4"D <br /> or Regulated 24VDC or FWR RTS151KEY Remote Test Station with Key <br /> Operating Voltage 8 to 33 VDC Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. <br /> (9 to 33 VDC with Sync•Circuit" Module) Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. <br /> Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC Total Current: 105 mA max. <br /> 17 mA RMS max. at 8 to 175 Volts FWR Alarm Response Time 40 seconds max. <br /> 29 mA RMS max. at 16 to 33 Volts DC Temperature Range —10 °C to 60°C (14 °F to 140 °F) <br /> 25 mA RMS max. at 16 to 33 Volts FWR Relative Humidity 95% non - condensing <br /> Temperature Range 0 °C to 49°C (32 °F to 120 °F) Wire Gauge 14 to 18 AWG <br /> Humidity Range 10 to 9396 non - condensing Dimensions 4.6" H x 2.75 "W x 1.8"D <br /> Nominal Sounder Frequency 3 kHz RTS2 and RTS2 -AOS Multi- signaling Accessory <br /> Wire Gauge 12 to 18 AWG Voltage 20 to 29VDC <br /> Dimensions 4.6" H x 2.9 "W x 0.45" D Power Requirements Standby: 3.0 mA max. <br /> RA100Z /RA100ZA Remote Annunciator Trouble: 16.0 mA max. <br /> Voltage Range Conventional System: 3.1 to 32 VDC Alarm without strobe: 30 mA max. <br /> Intelligent System: 18 to 32 VDC Alarm with strobe: 55 mA max. <br /> Maximum Alarm Current 12 mA Sounder 85 dBA at ten feet <br /> Dimensions 4.6 - H x 2.8 "W x 1.3"D Temperature Range —10°C to 60 °C (14 °F to 140 °F) <br /> Relative Humidity 95% non - condensing <br /> Wire Gauge 14 to 22 AWG <br /> Dimensions 4.8 "W x 53" H x 1.6"D <br /> For the very latest product specifications and listing information, please visit <br /> the System Sensor Web site at www.systemsensor.com. <br /> RTS1 S1 UL 54011 RTS151 KEY UL 52522 APA151 UL 54011 IAOS ULS2522 <br /> 1 <br /> RA100Z UL 52522 MHW UL 54011 MHR UL 54011 AOS <br /> VI SYSTEM 3825 System Sensor <br /> 3825 Ohio Avenue • St. Charles, IL 60174 Rodu tzpeofiotlanssu6je trochange wMart notice Vet ystemsenso com o <br /> �� SENSOR" Phone : 800- SENSOR2 • Fax: 630-377 495 ` 09flt product Information, 2`kangd1P •07840 � "� sheet. <br /> *05-0023A00. 5/09.01640 <br />
The URL can be used to link to this page
Your browser does not support the video tag.