Laserfiche WebLink
Project: 234 <br /> Title: Hope Pharmacy <br /> Type: Retail <br /> (WEA File: Tampa.tmy) <br /> Other Required Compliance <br /> Category Section Requirement (write N/A in box if not applicable) Check <br /> Report 13 -101 Input Report Print -Out from EnergyGauge FlaCom attached <br /> Operations Manual 13- 102.1, Operations manual provided to owner <br /> IZI <br /> 13 -410, 13 -413 <br /> Windows & Doors 13- 406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfin/ft all '' � i <br /> other products: 0.4 cfm /ft �--� <br /> Joints /Cracks 13- 406.AB.1.2 To be caulked, gasketed, weather - stripped or otherwise sealed <br /> El <br /> Dropped Ceiling 13- 406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof& <br /> ID <br /> Cavity side walls <br /> System 13 -407 HVAC Load sizing has been performed <br /> El <br /> Reheat 13 -407.B Electric resistance reheat prohibited <br /> EN <br /> HVAC Efficiency 13 -407, 13 -408 Minimum efficiences: Cooling Tables 13- 407.AB.3.2.1A -D; <br /> Heating Tables 13- 407.AB.3.2.1B, 13- 407.AB.3.2.1D, <br /> 1 3- 408.AB.3.2.1E, 13- 408.AB.3.2F <br /> HVAC Controls 13- 407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating <br /> and cooling in each zone; combined HAC deadband of at least 5 °F <br /> (exceptions) <br /> Ventilation Controls 13- 409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) <br /> exhaust systems and 2) systems with design outside air intake or <br /> exhaust capacity <300 cfin <br /> ADS 13 -410 Duct sizing and Design have been performed <br /> HVAC Ducts 13- 410.AB Air ducts, fittings, mechanical equipment & plenum chambers d MI <br /> shall be mechanically attached, sealed, insulated & installed per <br /> Sec. 13 -410 Air Distribution Systems <br /> Balancing 13- 410.AB.4 HVAC distribution system(s) tested & balanced. Report in <br /> construction documents <br /> Piping Insulation 13- 411.AB In accordance with Table 13- 411.AB.2 <br /> Water Heaters 13- 412.AB Performance requirements in accordance with Table 13- 412.AB.3. 3 <br /> Heat trap required <br /> Swimming Pools 13- 412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); <br /> El Readily accessible on /off switch <br /> Hot Water Pipe 13- 411.AB.3 Table 13- 411.AB.2 for circulating systems, first 8 feet of outlet <br /> Insulation pipe from storage tank and between inlet pipe and heat trap <br /> Water Fixtures 13- 412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public <br /> Cl lavatory fixture how water flow 0.5 gpm max; if self - closing valve <br /> 0.25 gallon recirculating, 0.5 gallon non recirculating <br /> Motors 13 -414 Motor efficiency criteria have been met <br /> Lighting Controls 13- 415.AB Automatic control required for interior lighting <br /> > <br /> in <br /> 5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring <br /> with 1 or 3 linear fluuorescent lamps >30W <br /> EnergyGauge Summit® v3.22 Incorporating Florida Energy Code Version - FLA/COM 2004 v2.5 Effective Dec 8, 2006 <br /> 3/30/2010 <br /> Page 8 of 8 <br />