wrightsoft AED Assessment Job: 05-1110 <br /> Date: May 06, 2010 <br /> F_. Entire House By: Roni Roberts <br /> CEA Builders <br /> 107 Teakwood Dr., Kissimmee, FL 34743 Phone: 407- 908 -2168 Fax: 407- 738 -4747 <br /> Pro'ect Information <br /> For: Michael and Rebecca Terrill <br /> 6144 10th Street, Zephyrhills, FL 33542 <br /> Design Conditions <br /> Location: Indoor: Heating Cooling <br /> Tampa, Intl AP, FL, US Indoor temperature ( °F) 70 75 <br /> Elevation: 10 ft Design TD ( °F) 20 17 <br /> Latitude: 28 °N Relative humidity (%) 50 50 <br /> Outdoor: Heating Cooling Moisture difference (gdlb) 11.9 54.0 <br /> Dry bulb ( °F) 50 92 Infiltration: <br /> Daily range (°F) - 17 (M ) Method Simplified <br /> Wet bulb (°F) - 77 Construction quality Average <br /> Wind speed (mph) 15.0 7.5 Fireplaces 0 <br /> Test for Ades uate Ex.osure Diversit <br /> Hourly Glazing Load <br /> 5,500 - <br /> 5,000- <br /> 4,500 <br /> t <br /> 4,000— <br /> g 3,500 - <br /> 0 3,000 — <br /> co <br /> 2,500 - <br /> 2,000- <br /> 1,500 - <br /> 1,000- <br /> 500- <br /> 0 1 l I 1 I I 1 1 1 I 1 <br /> 8 9 10 11 12 13 14 15 16 17 18 19 20 <br /> Hour of Day <br /> / Hourly f Average / AED limit <br /> Maximum hourly glazing load exceeds average by 28.4 %. <br /> House has adequate exposure diversity (AED), based on AED limit of 30 %. <br /> AED excursion: 0 Btuh <br /> BokVnaHc values have been manually overridden <br /> . + Wr.ghtsc - ft Right -Suite Residential 6.0.22 RSR42647 2010 - May -07 08:41:56 <br /> ACCA C: \My Documents \Wrightsoft HVAC\terrill addition CEA Zephyrhills.rrp Cale = MJ8 Orientation = N Page 1 <br />