Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: The Seven Springs Keystone Challenge 1254 Builder Name: Pasco County � r h` ,� <br /> Street: 38826 4th Ave. Permit Office: 64. o f Z LN <br /> City, State, Zip: Zephyrhills , Fl , 33542- Permit Number: (06 <br /> Owner: Jurisdiction: (e 1 ( ‘a 0 <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types (1154.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single - family a. Concrete Block - Int Insul, Exterior R=5.0 974.67 ft <br /> b. Frame - Wood, Adjacent R =11.0 180.00 ft <br /> 3. Number of units, if multiple family 1 c. N/A R= ft <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? No 10. Ceiling Types (1254.0 sqft.) Insulation Area <br /> 6. Conditioned floor area (ft 1254 a. Under Attic (Vented) R =30.0 1254.00 ft <br /> b. N/A R= ft <br /> 7. Windows(90.3 sqft.) Description Area c. N/A R= ft <br /> a. U- Factor: Sgl, U =0.47 90.33 ft <br /> SHGC: SHGC =0.36 11. Ducts <br /> b. U- Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Garage Sup. R= 6, 324 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor: N/A ft a. Central Unit Cap: 23.6 kBtu/hr <br /> SHGC: SEER: 15 <br /> d. U-Factor: N/A ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 24.0 kBtu/hr <br /> e. U- Factor: N/A ft2 HSPF:8.8 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types (1254.0 sqft.) Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1254.00 ft EF: 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.072 Total As -Built Modified Loads: 27.52 PASS <br /> Total Baseline Loads: 35.26 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ; • � • ., • <br /> • this calculation are in compliance with the Florida Energy specifications covered by this � _ . <br /> Code. calculation indicates compliance - ' ` ` . As <br /> �J v ry <br /> I C �c with the Florida Energy Code. ? /....10, o - so„ e 1. <br /> PREPARED Y t l/� ` Before construction is completed v • <br /> DATE: f . 1 - , 1 . 1 ( C? this building will be inspected for 0 a <br /> compliance with Section 553.908 ° <br /> Florida Statutes. 1 '�"� �' <br /> I hereby certify that this building, as designed, is in compliance '•. ..... . 4 <br /> with the Florida Energy Code. �' •• OD WE <br /> • .• <br /> OWNER /AGENT: BUILDIN OFFICIAL: / <br /> DATE: DATE: 4 '.2-ft) <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with N1110.A.3. <br /> 5/24/2010 10:27 AM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />