Laserfiche WebLink
Manual J Summer Calculations <br /> Residential Load - Component Details (continued) <br /> Project Title: Climate :FL_TAMPA_INTERNATIONAL_AP <br /> 38826 4th Ave. The Seven Springs Keystone Challenge 1254 <br /> Zephyrhills, Fl 33542- <br /> 5/24/2010 <br /> Sensible Envelope Load All Zones 10495 Btuh <br /> Sensible Duct Load 4351 Btuh <br /> Total Sensible Zone Loads 14846 Btuh <br /> Sensible ventilation 0 Btuh <br /> Blower 0 Btuh <br /> Whole House Total sensible gain 14846 Btuh <br /> Totals for Cooling Latent infiltration gain (for 56 gr. humidity difference) 1464 Btuh <br /> Latent ventilation gain 0 Btuh <br /> Latent duct gain 1136 Btuh <br /> Latent occupant gain (4 people Qa 200 Btuh per person) 800 Btuh <br /> Latent other gain 1400 Btuh <br /> Latent total gain 4800 Btuh <br /> TOTAL GAIN 19646 Btuh <br /> 1. Central Unit # 23600 Btuh <br /> *Key: Window types (Panes - Number and type of panes of glass) <br /> (SHGC - Shading coefficient of glass as SHGC numerical value) <br /> (U - Window U- Factor) <br /> (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) <br /> hearrerd <br /> - For Blinds: Assume medium color, half closed <br /> For Draperies: Assume medium weave, half closed <br /> For Roller shades: Assume translucent, half closed <br /> (IS - Insect screen: none(N), Full(F) or HalfO) <br /> (Ornt - compass orientation) MRS U €� <br /> Version 8 <br /> EnergyGauge® / USRFZB v2.8 Page 3 <br />