tqCti / Fire & Building <br /> Products <br /> Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 <br /> Series EC -11 & EC -14 — 11.2 and 14.0 K- factor <br /> Extended Coverage (Light and Ordinary Hazard) <br /> Upright, Pendent, and Recessed Pendent Sprinklers <br /> Corrosion resistant coatings, where <br /> General applicable, are utilized to extend the <br /> life of copper alloy sprinklers beyond <br /> Description that which would otherwise be ob- <br /> tained when exposed to corrosive at- '` <br /> The Tyco® Series EC -11 and EC -14 mospheres. Although corrosion resis- r - <br /> Extended Coverage Upright and Pen- tant coated sprinklers have passed the <br /> dent Sprinklers are decorative glass standard corrosion tests of the appli- 4 . ^' r <br /> P 9 PP 9 9 i <br /> bulbs rinklers desi ned for use in cable a roval a encies the testin is �Y <br /> light or ordinary hazard occupancies. not representative of all possible cor- <br /> They are intended for use in automatic rosive atmospheres. Consequently, it <br /> sprinkler stems designed in accord- ',,"1., _. <br /> P Y 9 is recommended that the end user be fi ; <br /> ance with standard installation rules consulted with respect to the suitability : . <br /> (e.g., NFPA 13) for a maximum cover- of these corrosion resistant coatings <br /> age area of 400 ft (37,2 m as com- for any given corrosive environment. <br /> pared to the maximum coverage area The effects of ambient temperature, <br /> of 130 ft (12,1 m for standard cover- concentration of chemicals, and <br /> age sprinklers used in ordinary haz- gas /chemical velocity, should be con - <br /> and occupancies or 225 ft (20,6 m sidered, as a minimum, along with the <br /> for standard coverage sprinklers used corrosive nature of the chemical to <br /> in light hazard occupancies. which the sprinklers will be exposed. <br /> The Series EC -11 and EC -14 Sprin- WARNINGS <br /> klers feature a UL and C -UL Listing <br /> that permits their use with unob The Series EC -11 and EC -14 Ex - Vi e' <br /> structed or non - combustible ob tended Coverage Sprinklers described <br /> structed ceiling construction as de- herein must be installed and main <br /> fined and permitted by NFPA 13, as tained in compliance with this docu- <br /> well as a specific application listing for ment, as well as with the applicabl ca <br /> use under concrete tees. standards of the National Fire Protec- <br /> tion Association, in addition to the <br /> The Series EC -11 and EC -14 Ex- standards of any other authorities hav- <br /> tended Coverage Sprinklers have ing jurisdiction. Failure to do so may <br /> been fire tested to compare their per- impair the performance of these de- <br /> formance to that of standard coverage vices. <br /> spray sprinklers. These tests have Model /Sprinkler <br /> shown that the protection provided is The owner is responsible for maintain- <br /> equal to or more effective than stand- ing their fire protection system and de- Ident <br /> and coverage spray sprinklers. vices in proper operating condition. <br /> The installing contractor or sprinkler Number <br /> manufacturer should be contacted <br /> with any questions. TY5137 - Upright, 11.2K <br /> IMPORTANT TY5237 - Pendent, 11.2K <br /> Always refer to Technical Data TY6137 - Upright, 14.0K <br /> Sheet TFP700 for the "INSTALLER TY6237 - Pendent,14.0K <br /> WARNING" that provides cautions TY5137 is a redesignation for C5137, <br /> with respect to handling and instal- <br /> lation of sprinkler systems and com- G1894, and S2510. <br /> ponents. Improper handling and in- TY5237 is a redesignation for C5237, <br /> stailation can permanently damage G1893, and S2511. <br /> a sprinkler system or its compo TY6137 is a redesignation for C6137, <br /> Hems and cause the sprinkler to fail <br /> to operate in a fire situation or cause G1896, and S2610. <br /> it to operate prematurely. TY6237 is a redesignation for C6237, <br /> G1895, and S2611. <br /> Page 1 of 8 DECEMBER, 2007 TFP220 <br />