Laserfiche WebLink
Schedule <br /> Fully Listed and FM Approved Sprinkler Pipe <br /> When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these • <br /> products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. <br /> Our Sch -10 (1 " - 8 ") pipe and Sch -40 (1 "- 2' / pipe have passed the same thorough lab testing as our other listed pipe . <br /> products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. <br /> Galvanized Pipe Sch-40 Specifications <br /> NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (241 Wt/Lift (25') <br /> Schedule-10/Schedule product can be In; mm In; mm Lbs /Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg <br /> "hot -dip" galvanized to meet FM 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 <br /> requirements for dry systems in P5 26.6 2.5 3.05 70 1,120 1,280 1,334 <br /> accordance with the zinc coating <br /> specifications of ASTM A -123. 11/2' 1.380 2.270 2.93 51 2,431 2,778 2,894 <br /> 32 35.1 4.36 4.36 51 1,103 1,260 1,313 <br /> Superior Coating 1 1.610 2.720 3.61 44 2,513 2,872 2,992 <br /> 40 40.9 4.0 5.37 44 1,140 1,303 1,357 <br /> Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 <br /> fers a clean, durable surface. It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 <br /> paint -ready for custom color applications 21/2 2.469 5.790 7.86 19 2,310 2,640 2,750 <br /> without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 <br /> The internal surface of all black Allied <br /> Tube & Conduit Fire Sprinkler pipe Sch•10 Specifications <br /> products up to 4.5000" in diameter is <br /> coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') WVLift (25') <br /> mula, "ABF ". In scientific laboratory In; mm In; mm Lbs /Ft; Kg /m Lbs /Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg <br /> test, ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 <br /> tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 <br /> walls, thereby delaying or possibly pre- 11/2" 1.442 1.810 2.52 61 2,319 2,664 2,760 <br /> venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 <br /> Influenced corrosion (MIC) when the 1 1.682 2.080 3.04 61 2,664 3,045 3,172 <br /> First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 <br /> American Made 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 <br /> 50 54.8 3.9 6.28 37 930 1,063 1,108 <br /> Meets "Buy American" requirement 21 2.635 3.530 5.89 30 2,224 2,542 2,648 <br /> and is available through distributors in 85 66.9 5.3 8.77 30 1,009 1,153 1,201 <br /> the USA, Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 <br /> 80 82.8 6.4 11.82 19 784 896 933 <br /> Specifications & Approvals <br /> 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 <br /> 90 108.2 8.3 17.53 19 1,015 1,160 1,209 <br /> Schedule -10 /Schedule - pipe are in <br /> compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 <br /> 125 134.5 11.56 25.80 10 740 846 881 <br /> ASTM A -135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 <br /> products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 <br /> of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 <br /> stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 <br /> tests: 0 <br /> • Welded Outlets <br /> • Hydrostatic Pressure Listed Approved Listed <br /> • Side Wall Rupture <br /> • Vibration Test <br /> 16100 S. Lathrop • Harvey, IL 60426 Customer Service: <br /> *L,CO / Flow Control c - ) IIie ^ 8 00 2 554 11350 Norcom Rd. • Philadelphia, PA 19154 Fax) 88 3 <br /> 8 554 806 <br /> TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 <br /> S5 - 3 <br />