• <br /> Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E- mail: kbarnett @fire.zephyrhills.fl.us <br /> Plan Review #: 10 -091 <br /> Project: Interior Remodel <br /> Number of Pages: 3 <br /> August 4, 2010 <br /> I have received and reviewed the plans for the interior remodel located at 6943 Gall Blvd and will <br /> allow the plans to move forward. By paying for permit contractor acknowledges to comply with <br /> the items below. Should anyone have any questions, please do not hesitate to contact the Fire <br /> Marshal's office. <br /> 1. Fire rated wall between the occupancies is a 1 hour rated wall. As the plans are <br /> submitted that is all the wall needs to be because the adjacent occupancy will be <br /> vacant because it is moving to this remodeled space. However, when that vacant <br /> space becomes occupied, pending on the occupancy classification the walls in that <br /> space may need to be upgraded to a two hour rated wall. It is the recommendation <br /> of this office to create a two hour rated wall on the interior of the remodel space <br /> because this wall has no partition walls tied into it, whereas, the opposite side of the <br /> wall does making it much more costly and complicated. If this is decided to be done <br /> submit a change showing the new design of the rated wall. It is also noted that back <br /> during the original plan review dated 5/24/04 similar language is noted on plan by <br /> this office that pending build -outs or remodels that greater fire separation may be <br /> required. NFPA 101, Table 6.1.14.4.1(b) provides the requirements for separation <br /> among occupancies. <br /> 2. Install certified fire extinguishers, one in front and one in the rear. <br /> 3. The dryer that is installed, ensure that the dryer ventilation duct is rigid smooth pipe. <br /> 4. Install emergency light in restroom. <br /> Inspection Required: <br /> 1. Firewall s ,ew inspect (each layer) and final, if changed. <br /> 2. Fi f <br /> n. <br /> KERRY :A '' TT, FIRE MARSHAL <br /> ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />