Laserfiche WebLink
1 c) ryr;; ZEPHYRHILLS FIRE DEPARTMENT <br /> t,s.1: 1140 <br /> Zephyrhills Florida 34248 <br /> • <br /> • 700 6th Avenue (813) 782 -8184 <br /> "l i.. c)°' <br /> October 29, 1986 <br /> ypt Chief ACLF <br /> T. Fenton Page 1 of 3 <br /> /,:; s ��t chief Casson, Inc. - Contractor <br /> hot„vrt Hartwig Project Name: LTC Care Center <br /> Location: Dairy Road - Behind K -Mart <br /> 1. Need total sq. ft.under roof. / 4!; ‘ ) ;/1 �»c}d S� <br /> 2. (a) Occupant load including staff. <br /> (b) Total number of beds. /e <br /> Sheet 2 (a) Each wing over 7,000 sq. ft. <br /> Need attic separation with 1 hr. fire rating (floor to underside of <br /> roof and extending out through oberhanger. Q' <br /> (b) Need access panels to attic each side of rated seperations. <br /> 3_ a6 <br /> (c) One hour fire rated smoke walls (partitions) at each wing <br /> with automatic release smoke doors - all rated walls smoke <br /> and fire shall have 5/8" type X each side. Fire rating of <br /> of doors in rated walls and corridors? W4c' 2c. bM.:J <br /> o C o <br /> ll <br /> (d) Kitchen hazard and maintenance hazard area - shall be 1 hr. <br /> fire rated. a <br /> e, �_ gG <br /> (e) Where is sprinkler and control room ? <br /> Sheet 3 (a) Need fire rating(s) of all carpets - minimum class B <br /> flame spread. a <br /> 3 - <br /> • <br />