Laserfiche WebLink
ARCHITECTURAL MATERIAL LEGEND <br />COMPACTED FILL OR EARTH <br />• :. ° : ] GRAVEL <br />IFrrFrrrrU CONCRETE BLOCK <br />FEFFEET CERAMIC TILE <br />CONCRETE <br />STRUCTURAL CONCRETE <br />FAT- ACOUSTICAL PANEL OR TILE <br />lI FACE BRICK <br />CONCRETE MASONRY UNITS (CMU <br />WOOD (FINISH) <br />PLYWOOD <br />I ROUGH LUMBER (CONTINUOUS) <br />[ -] ROUGH LUMBER (INTERMITTENT) <br />INSULATION (BATT, BLANKET, OR FILL) <br />fif Iffiffififfif ] RIGID INSULATION <br />STEEL (LARGE SCALE) <br />GYPSUM DRYWALL (GPOW) <br />GLASS (LARGE SCALE) <br />FINISH GRADE <br />SYMBOLS <br />O DETAIL, ELEVATION OR WALL SECTION NUMBER <br />100 DOOR NUMBER <br />1 DETAIL NUMBER <br />A -5 SHEET WHERE DETAIL <br />IS DRAWN <br />Q ELEVATION NUMBER <br />A -3 SHEET WHERE ELEVATION <br />IS DRAWN <br />9 <br />— OAA <br />7 <br />� a -io <br />O <br />O <br />D <br />T 2300- <br />,- 25 - <br />� 2s <br />COLUMN CENTER LINE <br />BUILDING SECTION OR <br />WALL SECTION NUMBER <br />SHEET WHERE SECTION <br />IS DRAWN <br />STOREFRONT OR WINDOW <br />PARTITION TYPE <br />REVISIONS <br />GLAZED PARTITION TYPE <br />NEW OR REQUIRED SPOT ELEVATION <br />EXISTING CONTOUR ELEVATION <br />NEW CONTOUR ELEVATION <br />LEVEL LINE FLOOR, ROOF, ETC. <br />PARTITION TYPES <br />TYPE DESCRIPTION <br />A� 3 5/8' METAL STUDS 16' O.C. W /1/2' GYPSUM DRYWALL EACH SIDE. <br />EXTEND FROM FLOOR TO 4' ABOVE CEILING. BRACE TO STRUCTURE 4' -0' O.C. <br />® SAME AS < , EXCEPT ADD SOUND - ATTENUATION BLANKETS BETWEEN <br />STUDS AND OUT 2' -0' ON CEILING EITHER SIDE OF PARTITION. <br />OC NOT USED <br />O <br />3 5/8' METAL STUDS 16' O.C. WITH 5/8 TYPE 'X', GYPSUM DRYWALL <br />T -1 <br />EACH SIDE FOR (1) HOUR U.L. RATED CONSTRUCTION. EXTEND PARTITION <br />T -2 <br />FROM FLOOR TO UNDERSIDE OF ROOF. <br />O <br />SAME AS <g> BUT ADD SOUND ATTENUATION BLANKETS BETWEEN STUDS <br />C -1 <br />TO CEILING AND OUT 2' -0' ON CEILING EACH SIDE. <br /><F> <br />i' -0 1/4' THICK WALL OF 4' NOMINAL BRICK VENEER & 8' CMU PARTION FROM <br />C -3 <br />FLOOR TO DECK ABOVE W/ AIR SPACE BETWEEN. ON INTERIOR SIDE PROVIDE <br />C -4 <br />3/4' METAL FURRING STRIP @ 16' O.C. W/ INSULATION BETWEEN & FACED W/ <br />C -5 <br />1/2' GYPSUM DRYWALL. (FURRING & INSULATION IN FINISHED AREAS ONLY). <br />C -6 <br />DAMPPROOF FACE OF CMU IN CAVITY. <br />< <br />8' CMU PARTITION, FLOOR TO UNDERSIDE OF ROOF DECK FOR (1) HOUR U.L. <br />A -2 <br />RATING. FURRED OUT ON FINISH ROOM AND CORRIDOR SIDES W/3/4' METAL <br />A -3 <br />FURRING 16' O.C. AND 1/2' GYPSUM DRYWALL; (1/2' DENSEBOARD FOR EPDXY <br />A -4 <br />COATING FINISH ON LOBBY AND ELEVATOR SIDES, GROUND AND SECOND <br />A -5 <br />FLOOR ONLY.) <br />ON 8' CMU PARTITION <br />OJ SAME AS OBUT NO GPOH ON INTERION SIDE. <br />0 SAME AS < BUT ADD TO CMU ON INTERIOR SIDE, 3/4' METAL FURRING <br />16' O.C. AND 1/2' GYP. DRYWALL IN FINISH ROOM AREAS <br />© ANODIZED ALUMINUM & REFLECTIVE TYPE GLASS CURTAIN WALL SYSTEM. <br />< CURTAINWALL SYSTEM GLAZED WITH SPANDREL REFLECTIVE GLASS AND 2 1/2' <br />METAL STUDS 16 O.C. WITH INSULATION BETWEEN AND FACED WITH M.R. <br />GYPSUM WALL BOARD, FLOOR TO CEILING. <br />P -1 <br />INDEX OF DRAWINGS <br />T -1 <br />TITLE SHEET <br />T -2 <br />INDEXES, LEGENDES 6 GENERAL INFORMATION <br />B -1 <br />BOUNDARY PLAN <br />C -1 <br />DEMOLITION PLAN <br />C -2 <br />SITE PLAN <br />C -3 <br />GRADING & DRAINAGE PLAN <br />C -4 <br />SANITARY SEWER MAIN <br />C -5 <br />SECTIONS G DETAILS <br />C -6 <br />SECTIONS 6 DETAILS <br />A -1 <br />MASTER GROUND FLOOR PLAN <br />A -2 <br />MASTER 2nd FLOOR PLAN <br />A -3 <br />GROUND FLOOR PLAN AREA 'A' <br />A -4 <br />GROUND FLOOR PLAN AREA 'B' <br />A -5 <br />GROUND FLOOR PLAN AREA 'C' <br />A -6 <br />SECOND FLOOR PLAN AREA 'A' <br />A -7 <br />SECOND FLOOR PLAN AREA 'B' <br />A -8 <br />SECOND FLOOR PLAN AREA 'C <br />A -9 <br />ROOF PLAN AND DETAILS <br />A -10 <br />BUILDING ELEVATION <br />A -11 <br />BUILDING ELEVATION <br />A -12 <br />CROSS SECTION AND DETAILS <br />A -13 <br />WALL SECTIONS <br />A -14 <br />ENLARGED TOILET ROOM PLAN AND DETAILS <br />A -15 <br />ENLARGED ELEVATOR PLAN AND DETAILS <br />A -16 <br />ENLARGED STAIR PLAN AND DETAILS <br />A -17 <br />INTERIOR CASEWORK <br />A -18 <br />INTERIOR CASEWORK <br />A-19 <br />FINISH SCHEDULES <br />A -20 <br />DOOR SCHEDULE AND DETAILS <br />A -21 <br />GROUND FLOOR REFLECTED CEILING PLAN <br />A -22 <br />2nd FLOOR REFLECTED CEILING PLAN <br />S -1 <br />FOUNDATION AND SLAB PLAN <br />S -2 <br />FOUNDATION SECTION AND DETAILS <br />S -3 <br />FOUNDATION SECTION AND DETAILS <br />S -4 <br />SECOND FLOOR FRAMING PLAN <br />S -5 <br />SECOND FLOOR SECTION <br />S -6 <br />ROOF FRAMING PLAN <br />S -7 <br />ROOF SECTIONS AND DETAILS <br />S -8 <br />CANOPY FRAMING AND SECTIONS <br />S -9 <br />SECTIONS AND DETAILS <br />S -10 <br />ENLARGED PLAN AT SKYLIGHT FRAMING <br />M -1 <br />GROUND FLOOR PLAN - MECHANICAL <br />M -2 <br />SECOND FLOOR PLAN AREA 'A' - MECHANICAL <br />M -3 <br />SECOND FLOOR PLAN AREA 'B' - MECHANICAL <br />M -4 <br />SECOND FLOOR PLAN AREA 'C' - MECHANICAL <br />M -5 <br />ROOF PLAN - MECHANICAL <br />M -6 <br />AHU SECTIONS <br />M -7 <br />SCHEDULES & DETAILS <br />M -8 <br />CONTROL DIAGRAMS <br />P -1 <br />GROUND FLOOR PLAN - PLUMBING <br />P -2 <br />GROUND FLOOR PLAN AREA 'B' <br />- PLUMBING <br />P -3 <br />SECOND FLOOR PLAN AREA 'A' <br />- PLUMBING <br />P -4 <br />SECOND FLOOR PLAN AREA 'B' <br />- PLUMBING <br />P -5 <br />SECOND FLOOR PLAN AREA 'C' <br />- PLUMBING <br />P -6 <br />SCHEDULES & DETAILS <br />P -7 <br />SANITARY PIPING DIAGRAM <br />P -8 <br />SANITARY PIPING DIAGRAM <br />P -9 <br />SANITARY PIPING DIAGRAM <br />E -1 <br />ELECTRICAL SITE PLAN <br />E -2 <br />FIRST FLOOR LIGHTING PLAN <br />(1/8') <br />E -3 <br />SECOND FLOOR LIGHTING PLAN <br />(1/8') <br />E -4 <br />FIRST FLOOR AREA 'B' POWER <br />& SIGNAL PLAN <br />(1/4 <br />E -5 <br />FIRST FLOOR AREA 'A' & 'C' <br />POWER & SIGNAL <br />PLAN (1/8' <br />E -6 <br />SECOND FLOOR AREA 'A' POWER <br />& SIGNAL PLAN <br />(1/4') <br />E -7 <br />SECOND FLOOR AREA ' B ' POWER <br />& SIGNAL PLAN <br />(1/4') <br />E -8 <br />SECOND FLOOR AREA 'C POWER <br />& SIGNAL PLAN <br />(1/4 <br />E -9 <br />DETAILS & LIGHTNING PROTECTION <br />E -10 <br />SCHEDULES & LEGEND <br />E -11 <br />PANELBOARDS <br />� o <br />'v <br />f0 y <br />O cr_ U <br />• to (D <br />z vi <br />N Q <br />0 <br />tyl cr. <br />W H O <br />-°° LL <br />H <br />(L <br />U x <br />j0 <br />U) <br />U) <br />Q cr <br />w <br />W 2 <br />}-, Lj <br />Qo <br />C) w a <br />Z <br />0 �a <br />J i-- 3 <br />• j N <br />(n N <br />• L r+ <br />U N <br />CD <br />H <br />G <br />cc <br />Lli <br />Lli <br />cd <br />U) <br />G <br />w <br />c� <br />w <br />u <br />w <br />ll <br />d <br />�_i <br />w• <br />U) <br />SUMOTS02 <br />� I <br />L _J <br />T -2 <br />