My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10443
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10443
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 9:59:52 AM
Creation date
8/15/2011 9:59:51 AM
Metadata
Fields
Template:
Building Department
Company Name
ALPHA VILLAGE
Building Department - Doc Type
Permit
Permit #
10-10443
Building Department - Name
BURKAM,RICHARD M & AMY
Address
7322 LEHIGH CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX 13 -D <br /> Climate Zones 4, 5, 6 <br /> TABLE 6C -1: PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDITIONS (500 Sq. Ft. and Less), RENOVATIONS TO EXISTNG BUILDINGS AND SITE - INSTALLED COMPONENTS OF MANUFACTURED HOMES <br /> COMPONENT MINIMUM INSULATION EQUIPMENT MINIMUM INSTALLED <br /> INSULATION INSTALLED EFFICIENCY EFFICIENCY <br /> Concrete Block R -5 5 c7 <br /> Frame, 2' x 4' R -11 Z Central NC - Split SEER =13.0' SEER = I,f <br /> Frame, 2' x 4' R -19 p T <br /> - Single Pkg. SEER = 13.0' SEER = <br /> 3 Common, Frame R -11 0 Room unit or PTAC EER = 8.5* EER = T <br /> Common, Masonry R -3 <br /> Under Attic R -30 3 D Electric Resistance ANY <br /> m 0 Heat pump - Split HSPF = 7.7' HSPF = <br /> in Single Assembly; Enclosed Z <br /> Z Frame R -19 r - Single Pkg. HSPF = 7.7• HSPF = <br /> MI Metal Pans R -13 w Room unit or PTHP COP = 2.7* HSPF /COP = <br /> LI <br /> Single Assembly; Open R -10 = <br /> Common, Frame R -11 Gas, natural or propane AFUE = .78 AFUE = <br /> LC Fuel Oil AFUE = .78 AFUE = <br /> Slab -on -grade No Minimum <br /> 0 Raised Wood R -11 <br /> O Raised Concrete R -5 t 1 <br /> LL 4 <br /> Common, Frame R -11 r_ w Electric Resistance EF = .92 EF = <br /> 2 a Gas; natural or LP -gas EF = .59 EF = <br /> U In unconditioned space R-6 t P' 3 Fuel Oil EF = .54 EF = <br /> o In conditioned space No minimum <br /> • <br /> TABLE 6C -2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY See Table 13 607.t.ABC.3.2 and 13 608.1.ABC.3.2 <br /> Maximum percentage glass to floor area allowed is selected by type, overhang length, and solar heat gain coefficient. Maximum % = Installed % = 4 <br /> GLASS TYPE, OVERHANG, AND SOLAR HEAT GAIN COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED <br /> UP TO 20% UP TO 30% UP TO 40% UP TO 50% <br /> Single Double Single Double Single Double Single Double <br /> OH -SHGC OH -SHGC OH -SHGC OH -SHGC OH -SHGC OH -SHGC OH -SHGC OH -SHGC <br /> 1' - .87 0' -.78 2' -.87 1' -.78 3' -.87 2' -.78 4' -.87 3' -.78 <br /> 0'- .75 1'- .75 0'- .61 2' -.75 1'- .61 3'- .75 2'- .61 <br /> 0' - .57 1' - .57 0' - .44 2' - .57 1' - .44 <br /> 0' - .39 1' - .39 0' - .35 <br /> 0' -.30 <br /> Get certified SHGC from the manufacturer or use defaults: Single clear SHGC = .75, double clear SHGC = .66, and single tint SHGC = .64 <br /> TABLE 6C -3 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather- stripped or otherwise sealed. <br /> Exterior Windows & Doors 606.1 Max. 0.3 cfm /sq.ft. window area; .5 cfm/sq.ft. door area. ' <br /> Sole & Top Plates 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. <br /> Recessed Lighting 606.1 Type IC rated with no penetrations (two altematives allowed). /LH <br /> Multistory Houses 606.1 Air barrier on perimeter of floor cavity between floors. Ali <br /> Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion devices with integral exhaust 4 <br /> ductwork. is <br /> Combustion Heating 606.1 Combustion space and water heating systems must be provided with outside combustion air, except for direct vent <br /> appliances. A/ <br /> Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker electric or cutoff y <br /> (gas) must be provided. Extemal or built -in heat trap required for vertical pipe risers. /� <br /> Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Noncommercial pools must have a pump timer. Gas spa & ` <br /> pool heaters must have minimum thermal efficiency of 78 %. t, ill <br /> Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units). ,cli <br /> Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 psig. <br /> HVAC Duct Construction, 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and A <br /> Insulation & Installation installed in accordance with the criteria of Section 610.1. Ducts in attics must be insulated to a minimum of R -6. 17 <br /> HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Z <br /> GENERAL DIRECTIONS: <br /> 1. On Table 6C -1 indicate the R -value of the Insulation being added to each component and the efficiency levels of the equipment being installed. All R- values and efficiencies installed must meet or exceed <br /> the minimum values listed. Components and equipment neither being added nor renovated may be left blank. <br /> 2. ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the addition as follows. Total the areas of all glass windows, sliding glass doors and glass door panels. Double the <br /> area of all nonvertical root glass and add It to the previous total. When glass in existing exterior walls is being removed or enclosed by the addition, an amount equal to the total area of this glass may be <br /> subtracted from the total glass area. Divide the adjusted glass area total by the conditioned floor area of the addition. Multiply by 100 to get the pecent. Rnd the largest glass percentage under which your <br /> calculated percentage falls on Table 6C -2. Prescriptives are given by the type of glass (single or double pane) and the overhang (OH) paired with a solar heat gain coefficient (SHGC). For a given glass type <br /> and overhang, the minimum solar heat gain coefficient allowed is specified. Actual glass windows and doors previously in the exterior walls of the housend being reinstalled In the addition do not have to <br /> comply with the overhang and solar heat gain coefficient requirements on Table 6C -2. All new glass in the addition must meet the requirement for one of the options in the glass percentage category you <br /> indicated. The overhang (OH) distance is measured perpendicularly from the face of the glass to a point directly under the outermost edge of the overhang. <br /> 3. RENOVATIONS ONLY. Replacement glass needs to meet the following requirements. Any glass type and solar heat gain coefficient may be used for glass areas which are under at least a 2 -foot overhang <br /> and whose lowest edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single -pane tinted, double -pane clear or double -pane <br /> tinted. <br /> 4. BUILDING SYSTEMS. Comply when new system is installed for system installed. <br /> 5. Complete the information requested on the top half of page 1. <br /> 6 Read 'Minimum Requirements for Small Additions and Renovations, Table 6C -3, and check all applicable items. <br /> 7. Read, sign and date the 'Owner /Agent' certification statement on page 1. <br /> 13 -D.36R FLORIDA BUILDING CODE - BUILDING <br />
The URL can be used to link to this page
Your browser does not support the video tag.