My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10950
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10950
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 11:23:48 AM
Creation date
8/15/2011 11:23:37 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS VILLAGE
Building Department - Doc Type
Permit
Permit #
10-10950
Building Department - Name
ASHINGTON MANAGEMENT LLC
Address
62158 ABBOTT STATIN DR UNITS 104
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- 1 _ _ _nee Ratings - ANSI/UL 263 Page 4 of 5 <br /> C. Fans c i�r..ets — Required for use with resilient channels, Item 6, 3 in. thick mineral wool batts, placed to fill <br /> interior of wail, :,:cached to the 4 in. face of the studs with staples placed 24 in. OC. <br /> THERI'tAFI &EP INC — Type SAFB <br /> 4D. Glass Fiber Insulation — (As an alternate to Item 4C) — 3 in. thick glass fiber batts bearing the UL Classification <br /> Marking as to :urface Burning and /or Fire Resistance, placed to fill the interior of the wall, attached to the 4 in. face of the <br /> studs with sta, s placed 24 in. OC. See Batts and Blankets (BKNV or BZJZ) Catagories for names of Classified <br /> companies. <br /> 4E. 6stts and blankets* — (Required for use with Wall and Partition Facings and Accessories, Item 2A) — Glass fiber <br /> insulation, nom 3 -1/2 in. thick, min. density of 0.80 pcf, with a flame spread of 25 or less and a smoke developed of 50 or <br /> less, friction - fi ted to completely fill the stud cavities. See Batts and Blankets Category (BKNV) for names of manufacturers. <br /> 43. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 4) - Spray applied cellulose fiber. The fiber is applied <br /> with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. <br /> The minimun Iry density shall be 4.30 lbs/ft <br /> INTERNATIONAL CELLULOSE CORP — Celbar - RL <br /> 5 Steel Framing Members (Optional, Not Shown)* — Furring channels and Steel Framing Members as described <br /> below: <br /> a. Furring Channels — Formed of No. 25 MSG galv steel. 2 -3/8 in. wide by 7/8 in. deep, spaced 24 in. OC perpendicular <br /> tc studs. Channels secured to studs as described in Item b. Ends of adjoining channels are overlapped 6 in. and tied <br /> together with double strand of No. 18 SWG galv steel wire near each end of overlap. As an alternate, ends of adjoining <br /> channels may oe overlapped 6 in. and secured together with two self- tapping #6 framing screws, min. 7/16 in. long at the <br /> midpoint of the overlap, with one screw on each flange of the channel. Wallboard attached to furring channels as described <br /> n :gem 2. <br /> b. Steel Framing Members* — used to attach furring channels (Item a) to studs (Item 1) . Clips spaced 48 in. OC., and <br /> secured to studs with No. 8 x 2 -1/2 in. coarse drywall screw through the center grommet. Furring channels are friction <br /> fitted into clips. <br /> PAC INTERNATIONAL INC — Type RSIC - <br /> 6. Furring Channel — Optional - Not Shown - For use on one side of the wall - Resilient channels, 25 MSG galv steel, <br /> spaced vertically 24 in. OC, flange portion screw attached to one side of studs with 1 -1/4 in. long diamond shaped point, <br /> double lead Phillips head steel screws. When resilient channels are used, insulation, Items 4C or 4D is required. <br /> 5A. Steel Framing Members* — Optional - Not Shown - Used as an alternate method to attach resilient channels (Item <br /> 6) to one side of studs only. Clips attached at each intersection of the resilient channel and the wood studs (Item 1). <br /> Resilient channels are friction fitted into clips, and then clips are secured to the wood stud with min. 1 -3/4 in. long diamond <br /> shaped point, double lead Phillips head steel screws through the center hole of the clip and the resilient channel flange. <br /> KEENE BUILDING PRODUCTS CO INC — Type RC Assurance. <br /> 7. Wall and Partition Facings and Accessories* — (Optional, Not shown) — Nominal 1/2 in. thick, 4 ft wide panels, for <br /> optional use as an additional layer on one or both sides of the assembly. Panels attached in accordance with manufacturer's <br /> recommendations. When the QR -510 panel is installed between the wood framing and the UL Classified gypsum board, the <br /> required UL Classified gypsum board layer(s) is /are to be installed as indicated as to fastener type and spacing, except that <br /> the required fastener length shall be increased by a minimum of 1/2 in. Not evaluated or intended as a substitute for the <br /> required layer(s) o UL Classified Gypsum Board. <br /> SERIOUS MATERIALS INC — Type QuietRock QR -510. <br /> 8. Cementitious Backer Units* — (Optional Item Not Shown - For Use On Face Of 1 Hr With All Standard Items <br /> Required) - 1/2 in., 5/8 in., 3/4 in. or 1 in. thick, min. 32 in. wide.- Applied vertically or horizontally with vertical joints <br /> centered over studs. Fastened to studs and runners with cement board screws of adequate length to penetrate stud by a <br /> minimum of 3/8 in. for steel framing members, and a minimum of 3/4 in. for wood framing members spaced a max of 8 in. <br /> OC. When 4 ft. wide boards are used, horizontal joints need not be backed by framing. <br /> l <ATIONAL GYPSUM CO — Type PermaBase <br /> 9. Non- Bearing Wall Partition Intersection — (Optional) Two nominal 2 by 4 in. stud or nominal 2 by 6 in. stud nailed <br /> together with two Sin. long 10d nails spaced a max. 16 in. OC. vertically and fastened to one side of the minimum 2 by 4 <br /> http: / /database.ui . co _n% c ai- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =B... 8/31/2010 <br />