My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10950
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10950
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 11:23:48 AM
Creation date
8/15/2011 11:23:37 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS VILLAGE
Building Department - Doc Type
Permit
Permit #
10-10950
Building Department - Name
ASHINGTON MANAGEMENT LLC
Address
62158 ABBOTT STATIN DR UNITS 104
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills. 11 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (81 3) 780 -0044 <br /> l mail: kbarnett (tr)fire.rephyrhills.fl.us <br /> Plan Review #: 10- 106 <br /> Project: Interior Remodel <br /> Number of Pages: 5 plus firewall listing, plot plan, finish & door schedule <br /> September 17, 2010 <br /> I have received and reviewed the plans for the interior remodel located at 6215 Abbott <br /> Station Dr ( #104/105) and will allow the plans to move forward. By paying for permit, <br /> contractor acknowledges to comply with the comments below. Should anyone have any <br /> questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. A 60 minute rated fire door shall be installed where the rated wall is opened up. <br /> After discussing with builder it is decided to swing that door in and install mag <br /> locks connected to the fire alarm to allow the door to shut upon alarm activation. <br /> Door specs shall be submitted to this office prior to installation. <br /> 2. The rated wall being installed to the west, builder shall submit engineered <br /> drawings of how that 1 hour rated wall will be constructed. Drawings shall be <br /> submitted to this office prior to its construction for approval. <br /> 3. The fire alarm contractor shall submit plans, cut sheets and scope of work on the <br /> changes being made to the fire alarm system to obtain a permit to perform this <br /> work. System shall be addressable with a new zone map. <br /> 4. On the south end by the exit there is some equipment on the wall. Maintain 4 feet <br /> of space in front of that equipment to provide for adequate egress space. <br /> 5. Ensure there are certified fire extinguishers within 75' of travel. There shall be at <br /> least one in the new interior space. <br /> 6. Install lightweight truss signs in accordance with FAC 69A- 60.008. Sign shall be <br /> an "R" sign mounted at each main door (left side) at a height between 4 — 6 feet. <br /> 7. Exit light in west office not required. Cannot exit through an office. <br /> 8. On South exit where break /conference room is, ensure there is only a single <br /> motion on the door to get out such as a hotel style latch. <br /> 9. Add emergency light in handicap restroom. <br /> 10. Any penetrations to the firewall by the A/C shall have rated fire dampers. Any <br /> other penetrations for electrical, alarm, telephone, etc... shall be a listed method <br /> to maintain the rating. The method shall be submitted to this office. <br /> 11. If A/C is over 2000 cfm's a duct detector shall be installed and tied into the fire <br /> alarm system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.