Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1371 ST CROIX 214 A N B Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner. LENNAR Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Exterior R =4.1 998.67 ft <br /> b. N/A R= ft' <br /> 3. Number of units, if multiple family 1 c. N/A R= ft2 <br /> 4. Number of Bedrooms 3 d. N/A R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 1371 a. Under Attic (Vented) R =30.0 686.00 ft <br /> 6. Conditioned floor area (ft2) b N/A R= ft' <br /> 7. Windows Description Area c. N/A R= ft <br /> a. U- Factor. Dbl, U =0.60 182.25 ft2 11. Ducts <br /> SHGC: SHGC =0.32 <br /> b. U- Factor. N/A ft' a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 265 ft <br /> SHGC: 12. Cooling systems <br /> c. U- Factor. N/A ft a. Central Unit Cap: 28 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U- Factor. N/A ft2 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 28 kBtu/hr <br /> e. U- Factor: N/A ft HSPF: 8.2 <br /> SHGC: 14. Hot water systems <br /> 8. Floor Types Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab -On -Grade Edge Insulation R =0.0 1371.00 ft= EF: 0.92 <br /> b. N/A R= ft' b. Conservation features <br /> c. N/A R= ft2 None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.133 Total As -Built Modified Loads: 33.08 PASS <br /> Total Baseline Loads: 40.16 <br /> I hereby certify that the plans and specifications covered by Review of the plans and F' <br /> this calculation are in compliance with the Florida Energy specifications covered by this ••.• *, 0 � 0�;'•., <br /> Code. calculation indicates compliance 7 '` • 4 - 5 3 ` �' :• <br /> with the Florida Energy Code. f - nsr. "4 , Al;f'' . ' , . 0 <br /> PREPARED B • et l Before construction is completed - �y" h' � 1 <br /> DATE: this building will be inspected for Via" , . <br /> compliance with Section 553.908 Florida Statutes. • '., : * ° ; r <br /> .4' C '- ' <br /> 1 hereby certify that this building, as design ,I •. OD W 6;'� •, is in compliance p <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFI • . dry• , <br /> DATE: a A MP/ DATE: <br /> - Compliance requires certification' • y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 1:29 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />