My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10973
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10973
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 1:59:27 PM
Creation date
8/15/2011 1:59:25 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
10-10973
Building Department - Name
LENNAR HOMES INC
Address
6328 TIMBERLY LN BLDG 11 LOT 106
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> DOORS <br /> IW # Ornt Door Type <br /> 1 Storms U -Value Area <br /> N Insulated <br /> None 0.6 20 ft <br /> Window orientation below is as entered. Actual orientation is led b rotate an! le shown in 'Pro <br /> / ct" section above. <br /> Ov <br /> V # Omt Frame Panes NFRC U- Factor SHGC Storms Area De th Se Int Shade <br /> 1 N Metal Low -E Double Yes p p Screening <br /> 0.6 0.32 N 15.93 ft 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> 2 N Metal Low -E Double Yes <br /> 0.6 0.32 N 15.75 ft 1 ft 0 in 12 ft 0 in HERS 2006 None <br /> 3 N Metal Low -E Double Yes 0.6 0.32 N 14.24 ft 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> 4 N Metal Low -E Double Yes 0.6 0.32 N 15.75 ft 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> 5 S Metal Low -E Double Yes <br /> 6 S 0.6 0.32 N 32.38 ft 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> Metal Single (Clear) Yes 1.17 <br /> 0.74 N 40 ft 6 ft 0 in 1 ft 0 in HERS 2006 None <br /> 7 N Metal Low -E Double Yes 0.6 <br /> 0.32 N 6.94 ft 5 ft 0 in 1 ft 0 in HERS 2006 None <br /> V / INFILTRATION & VENTING <br /> v Method SLA CFM 50 ACH 50 — Forced Ventilation — Run Time Fan <br /> ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0.00036 1446 7.08 79.4 149.3 0 cfm <br /> 0 cfm 0 0 <br /> Wr COOLING SYSTEM <br /> # System Type Subtype <br /> Efficiency Capacity Air Flow SHR Ductless <br /> 1 Central Unit None <br /> SEER: 14 34 kBtu /hr 1020 cfm 0.75 False <br /> lir # System Type Subtype <br /> E <br /> 1 Electric Heat Pump None Efficiency Capacity Ductless <br /> HSPF: 8.2 34 kBtu/hr False <br /> HOT WATER SYSTEM <br /> W # System Type EF <br /> 1 Electric Cap Use SetPnt Conservation <br /> 0.92 40 gal 50 gal 120 deg <br /> None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC <br /> Cert # Company Name Collector Storage <br /> System Model # Collector Model # Area Volume <br /> FEF <br /> DUCTS <br /> V — Supply — — Return — <br /> # Location R -Value Area Location Au Percent <br /> Area Leakage Type Handler CFM 25 Leakage ON RLF <br /> 1 Attic 6 355 ft2 Attic <br /> 4 ft2 Default Leakage Interior <br /> 3/24/2009 2:51 PM <br /> EnergyGauge® USA - FlaRes2008 <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.