My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10973
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10973
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 1:59:27 PM
Creation date
8/15/2011 1:59:25 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
10-10973
Building Department - Name
LENNAR HOMES INC
Address
6328 TIMBERLY LN BLDG 11 LOT 106
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> FORM 1100A -08 <br /> Code Compliance Cheklist <br /> Residential Whole Building Performance Method A - Details <br /> ADDRESS: <br /> TAMPA, FL, PERMIT #: <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE <br /> Exterior Windows & Doors NI106.A61 1 Maximum: .3 cfrn/s•. <br /> Exterior & Adjacent Walls gasket, ft. window area' .5 cfm /s..ft. door area. 11.11 N Caulk, asket weatherstrip or seal between: windows /doors & <br /> frames, surrounding wall; foundation & wall sole or sill plate; joints <br /> between exterior wall panels at corners; utility penetrations; <br /> between wall panels & top /bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> installed that extends from, and is sealed to, the foundation to the <br /> Floors to • .late. <br /> N1106•AB -1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> Ceilings is installed that is sealed to the • - rimeter • - netrations and seams. <br /> N Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. <br /> Recessed Lighting Fixtures N Type IC rated with no penetrations, sealed; or Type IC non-IC <br /> rated, installed inside a sealed box with 1/2" clearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi -sto Houses <br /> N Air barrier on • - rimeter of floor cav' between <br /> Additional Infiltration reqts NI 106.AB.1.3 Exhaust fans vented to outdoors, damper; combustion space <br /> heaters comply with NFPA, have combustion air. El <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS SECTION REQUIREMENTS <br /> IMMO <br /> Comply with efficiency requirements in Table N112.ABC.3. Switch <br /> or clearly marked circuit breaker (electric) or cutoff (gas) must be <br /> • rovided. External or built -in heat tra • re • uired. <br /> Swimming Pools & Spas N1112.AB.2.3 <br /> Spas & heated pools must have covers (except solar heated). <br /> Non - commercial pools must have a pump timer. Gas spa & pool <br /> heaters must have a minimum thermal efficiency of 78%. <br /> Shower heads Heat • um • • •oi heaters shall have a minimum COP of 4.0. <br /> N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per <br /> m inute at 80 PSIG. MI <br /> Air Distribution Systems N1110.AB <br /> All ducts, fittings, mechanical equipment and plenum chambers <br /> shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Section NI 110.AB. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br /> HVAC Controls N1107.AB.2 <br /> Separate readily accessible manual or automatic thermostat for <br /> Insulation each s stem. <br /> N1104.AB.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both <br /> N1102.B.1.1 sides. Common ceiling & floors R -11. <br /> 3/24/2009 2:51 PM <br /> EnergyGauge® USA - FlaRes2008 <br /> Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.