Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 D Builder Name: LENNAR <br /> Street: Permit Office: Ci cief 1 Z r-ipw <br /> City, State, Zip: TAMPA , FL , Permit Number: y s <br /> J <br /> Owner LENNAR HOMES Jurisdiction: J 73 <br /> Design Location: FL, Tampa / ! 6,61.i) <br /> 1. New construction or existing New (From Plans) 9. Wall Types <br /> Insulation Area <br /> 2. Single family or multiple family Multi- family a. Concrete Block - Int lnsul, Exterior R=4.1 541.33 ft <br /> 3. Number of units, if multiple family 1 b. N/A R= ft' <br /> c. N/A R= ft2 <br /> 4. Number of Bedrooms 2 d. N/A <br /> R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types <br /> Insulation Area <br /> 6. Conditioned floor area (ft2) 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= <br /> fP <br /> a. U- Factor: Dbl, U =0.60 100.98 ft2 c. N/A R= <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: Sgl, U =1.17 40.00 ft' a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft2 a. Central Unit <br /> SHGC: Cap: 34 kBtufir <br /> d. U-Factor: N/A SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu /hr <br /> e. U- Factor: N/A ft' <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft' a. Electric Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft' <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy O� SHE Srq�; •. • <br /> Code. r9y specficetions covered by this ��.. , _ � •. <br /> calculation indicates compliance ' 4r` ; ' es ' 9 CO IZ4,1 • PREPARED BY: De „� r with the Florida Energy Code. ° : No , . " :k . :0. ,, 0`- <br /> Before construction is completed a � =+ _�;; <br /> DATE: this building will be inspected for "'' <br /> i � <br /> compliance with Section 553.908 C7 a ` <br /> :: <br /> I hereby certify that this building, as desig - . , is i .41 pliance Florida Statutes. I ' . "' ° <br /> i/ %.1? with the Florida Energy Code. <br /> OWNER/AGENT AN∎ <br /> `-�__ DATE: BUILDING OFFICIAL: <br /> DATE: <br /> N - <br /> Compliance requires certifies +� , <br /> - Com <br /> P q by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-se. ed in accordance with NI110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />