My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10974
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10974
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2011 2:01:09 PM
Creation date
8/15/2011 2:01:07 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
10-10974
Building Department - Name
LENNAR HOMES INC
Address
6330 TIMBERLY LN BLDG 11 LOT 107
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
wrightsoft P roject Summary Job: MARTINIQUE 1531 <br /> Entire House Date: 6/21/2007 <br /> By: JP <br /> Bayonet Plumbing Heating and Air <br /> 8950 New York Ave, Hudson, FL 34674 Phone: 727 -888 -4838 Fax: 727- 863 -7237 <br /> Project Information <br /> For: LENNAR HOMES <br /> L <br /> Notes: <br /> Desi e n Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db Outside db <br /> Inside db 0 °F ° <br /> Design TD 95 °F <br /> Design TD 30 °F <br /> Design TD 20 °F <br /> Daily range <br /> Relative humidity 50 % <br /> Moisture difference 62 gr /Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 21027 Btuh Structure <br /> Ducts 5536 Btuh Ducts 17813 7681 Btuh <br /> Btuh <br /> Central vent (43 cfm) 1427 Btuh Central vent (43 cfm) 7 951 Btuh <br /> Humidification 0 Btuh Blower <br /> Piping 0 Btuh 0 Btuh <br /> Equipment load 27990 Btuh Use manufacturer's data <br /> Rate/swing ultipplier n <br /> Infiltration Equipment sensible load 1.00 <br /> 26446 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi -tight 9 <br /> Fireplaces 0 Structure <br /> g g Ducts 2341 Btuh <br /> ( ) Heating g Co15 Central vent (43 cfm) 1814 Btuh <br /> Area ft= Equipment latent load <br /> Volume (ft3) 12248 12248 6245 Btuh <br /> Air changes/hour 0.34 0.18 Equipment total load <br /> Equiv. AVF (cfm) 69 37 Req. total capacity at 0.70 SHR 32 3.1 totnh <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make <br /> Trade Make <br /> Model Trade <br /> ARI ref no. Cond <br /> Coil <br /> Efficiency 8.2 HSPF ARI ref no. <br /> Heating input Efficiency 14 SEER <br /> Heating output 0 Btuh @ 47 °F atentcoolingng 0 Btuh <br /> Temperature rise F Total cooling 0 Btuh <br /> 0 <br /> Actual air flow 1200 cfm Actual air flow 0 cfm <br /> Air flow factor 0.045 cfm /Btuh Air flow factor 0.047 cfm <br /> Static pressure 0 in H2O Static pressure 0. 0 in H20 <br /> in H2 uh cf <br /> Space thermostat Load sensible heat ratio O <br /> 0.81 <br /> Bold/Italic values have been manually overridden <br /> Printout certified by ACCA to meet all requirements of Manual J 8th Ed. <br /> Acck - wriyhtsoy - RightSuite® Universal 7.1.08 RSU05714 <br /> 1531 MARTINQUE REV.rup Calc = MJ8 Orientation .. E 2009-Mar-25 09:08:25 <br /> Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.