Laserfiche WebLink
• <br /> FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 MARTINQUE 214 0 Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft' <br /> 2. Single family or multiple family Multi- family <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> c. N/A R= ft <br /> 4. Number of Bedrooms 2 d. N/A R= ft2 <br /> 5. Is this a worst case? Yes 10. Ceiling Types Insulation Area <br /> 6. Conditioned floor area (ft') 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= ft= <br /> a. U- Factor: Dbl, U =0.60 100.98 ft' c' N/A R= ft' <br /> SHGC: SHGC =0.32 11. Ducts <br /> b. U- Factor: SgI, U =1.17 40.00 ft' a. Sup: Attic Ret Attic AH: Interior Sup. R= 6, 355 ft= <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor: N/A ft' a. Central Unit Cap: 34 kBtu/hr <br /> SHGC: <br /> SEER: 14 <br /> d. U- Factor: N/A ft2 13. Heating systems <br /> SHGC: g <br /> e. U- Factor: N/A ft2 a. Electric Heat Pump Cap: 34 kBtu/hr <br /> SHGC: HSPF: 8.2 <br /> Types 14. Hot water systems <br /> 8. Floor T <br /> YP Insulation Area a. Electric <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft2 Cap: 40 gallons <br /> b. Raised Floor R =19.0 88.00 ft2 EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.092 Total As -Built Modified Loads: 30.94 PASS <br /> Total Baseline Loads: 38.54 <br /> I hereby certify that the plans and specifications covered by Review of the plans and SiiE Sr <br /> 4 ...._ _... A <br /> this calculation are in compliance with the Florida Energy specifications covered by this '�, � 9. ; ,.*: calcul ; .,.c.-,,; <br /> Code. ,9 - r . _ . o +�, <br /> calculation indicates compliance Sky y � � , . . - <br /> PREPARED BY: pe.....k,A) with the Florida Energy Code. A. ui, � k�., . .. �ti "" O \Before construction is completed ` a : . __,:,4,_ DATE: MP . this building will be inspected for <br /> 4... � ;II . x. <br /> compliance with Section 553.908 F ,� * _' <br /> I hereby certify that this building, as design 4 , i; in c• r •liance Florida Statutes. `;xr.�' ,�, <br /> with the Florida Energy Code. / /�� CpD O°`� <br /> OWNER/AGENT: A / M <br /> DATE: r TA�P, DATE:ING OFFIFIAL: M , I <br /> -- <br /> - Compliance requires certificati , by the air handler unit manufacturer that the air h ndler enclosure <br /> qualifies as certified factory-sea - • in accordance with N1110.A.3. <br /> 3/24/2009 2:51 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 <br />