Laserfiche WebLink
FORM 1100A -08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1531 SIESTA KEY 214 C Builder Name: LENNAR <br /> Street: Permit Office: <br /> City, State, Zip: TAMPA , FL , Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area <br /> a. Concrete Block - Int Insul, Exterior R=4.1 541.33 ft' <br /> 2. Single family or multiple family Multi - family <br /> 3. Number of units, if multiple family 1 b. N/A R= ft2 <br /> c. NIA R= ft2 <br /> 4. Number of Bedrooms 2 d. WA <br /> R= ft <br /> 5. Is this a worst case? Yes 10. Ceiling Types <br /> Insulation Area <br /> 6. Conditioned floor area (ft 1531 a. Under Attic (Vented) R =30.0 766.00 ft <br /> 7. Windows Description Area b. N/A R= ft2 <br /> a. U- Factor: Dbl, U =0.60 119.64 ft2 c. N/A R= ft= <br /> SHGC: SHGCO.32 11. Ducts <br /> b. U- Factor. Sgl, U =1.17 33.33 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 355 ft <br /> SHGC: SHGC =0.74 12. Cooling systems <br /> c. U- Factor. N/A ft2 a. Central Unit <br /> SHGC: Cap: 34 kBtu/hr <br /> d. U- Factor: N/A ft2 SEER: 14 <br /> SHGC: 13. Heating systems <br /> a. Electric Heat Pump Cap: 34 kBtu/hr <br /> e. U- Factor: N/A ft2 <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types Insulation Area 14. Hot water systems <br /> ns <br /> a. Slab -On -Grade Edge Insulation R =0.0 1531.00 ft2 a. Electric Cap: 40 galb <br /> b. Raised Floor R =19.0 88.00 ft EF: 0.92 <br /> b. Conservation features <br /> c. N/A R= ft <br /> None <br /> 15. Credits Pstat <br /> Glass /Floor Area: 0.100 Total As -Built Modified Loads: 30.62 PASS <br /> Total Baseline Loads: 38.54 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance ' the Florida Energy specifications covered by this ��yy ' <br /> Code. calculation indicates compliance ;' ; �' ".' �'{' <br /> with the Florida Energy Code. t ► , ' . <br /> PREPARED BY: �.'s" -! with gy n���.: ' :Al <br /> ; ` " „. O . <br /> • <br /> .-1 _ Before construction is completed a r` = _..y: - ; 4 <br /> DATE: this building will be inspected for O a <br /> compliance with Section 553.908 ?n <br /> I hereby certify that t • uildin as deli • , 0 • Florida Statutes. * ,L .✓ �,"' a ` <br /> with the Florida Energy Code. 9 � ' �r•liance •= <br /> OWNER/AGENT: AeilI =1, BUILDING / i DATE: LKt� ∎! UILDING OFFICIAL: r, <br /> ; 1 _ �� DATE: 1 <br /> ■ <br /> 1 10 <br /> - Compliance requires certification • y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory- sealed in accordance with NI110.A.3. <br /> 3/24/2009 2:22 PM EnergyGauge® USA - FlaRes2008 <br /> Page 1 of 5 <br />