Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> B Consultine and Engineering Services for the Building Industry <br /> P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate of Authorization No. 9813 <br /> Product Evaluation Report Report No.: FL- 10991.5 R3 <br /> Date: December 17, 2009 <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Alside Window Company Model 0202 <br /> Window Horizontal Slider 3773 State Road Horizontal Slider <br /> Cuyahoga Falls, OH 44223 "Non- Impact" <br /> Phone 330.922.2108 <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for <br /> Alside Window Company, based on Rule Chapter No. 9B- 72.070, Method 1A of the State of Florida Product Approval, <br /> Dept. of Community Affairs - Florida Building Commission. <br /> RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code structural requirements excluding the "High <br /> Velocity Hurricane Zone ". <br /> 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When dsed in areas requiring wind borne debris protection, this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609.1.2 of the Florida Building Code. <br /> 4. For through the frame anchoring in 2x stud construction, anchoring of these units shall be the same as that shown for 2x buck masonry <br /> construction. <br /> 5. Site conditions that deviate from the details of drawing FL- 10991.5 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL- 10991.5 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> ATI 63479.02 - 501 -47 AAMA/WDMA/CSA 101/I.S.2/A440 -05 Architectural Testing, Inc. Michael L. Mackereth <br /> ATI 80747.02- 501 -47 AAMA/WDMA/CSA 101/I.S.2/A440 -05 Architectural Testing, Inc. Lynn George <br /> 2. Drawing No. Prepared by Signed & Sealed by <br /> No. FL 10991.5 RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. <br /> 3. Calculations Prepared by Signed & Sealed by <br /> Product Anchoring RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. <br /> Buck Anchoring RW Building Consultants, Inc. (CA #9813) Lyndon F. Schmidt, P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc., certifying that Alside Window Company is <br /> manufacturing products within a quality assurance program that complies with ISO /IEC 17020 and Guide 53 <br /> Lyndon F. Schmidt, P.E. <br /> FL PE No. 43409 <br /> December 17, 2009 <br /> PF 1393 Sheet 1 of 1 <br />