My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-11103
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-11103
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2011 9:38:29 AM
Creation date
8/16/2011 9:38:24 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-11103
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7320 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett @fire.zephyrhills.fl.us <br /> Plan Review #: 10 -127 <br /> Project: Interior Renovation/Reconstruction <br /> Number of Pages: 21 <br /> October 27, 2010 <br /> I have received and reviewed the plans for the interior remodel /reconstruction of a single tenant <br /> space into two separate units located at 7320 Gall Blvd and will allow it to move forward under <br /> the following conditions listed below. Paying for permit, the contractor acknowledges complying <br /> with those conditions. Should anyone have any questions, please do not hesitate to contact the <br /> Fire Marshal's office. <br /> Inspections Required: <br /> 1. This structure contains and existing fire sprinkler system, however, now the structure is <br /> being divided into 2 separate units. The fire sprinkler system shall be separated into two <br /> systems each having its own riser. If unable to do, then system shall have a water flow <br /> valve installed at each unit to indicate where the flow is occurring. The FDC connection <br /> shall be a 5" turndown Storz connection. There shall be a sign above the connection <br /> stating FDC. Lettering shall be 6 "red reflective letters on white background. Separate <br /> plans, cut sheets, details, calcs, etc... will be required to obtain a permit to complete this <br /> work. Ensure the all canopies have sprinkler protection. <br /> 2. This structure contains and existing fire alarm system, however, now the structure is <br /> being divided into 2 separate units. The fire alarm system shall be separated into two <br /> systems if the sprinkler system is separated. If not, the system shall be an addressable <br /> system with every device programmed to the panel with a location. The device shall be <br /> labeled to match the panel program. Ensure duct detectors are tied into the system. <br /> Separate plans, cut sheets, details, calcs, etc... will be required to obtain a permit to <br /> complete this work. Ensure there is an outside strobe horn at the main door of each unit. <br /> 3. Extinguisher location may need to be changed to ensure they are visible. Extinguisher <br /> placarding may be required showing location. <br /> 4. Ensure secondary exits have panic hardware. <br /> 5. Ensure address is located at front and rear of building. 6" numerical numbers required. <br /> 6. The building contains lightweight bar joist trusses. Per FAC 69A- 60.008, a lightweight <br /> truss sign shall be installed on the building. An "R" sign will be the correct one. It shall <br /> be located at the main door and every 100 feet. It shall also be required at each <br /> secondary exit door. <br /> 7. Ensure main disconnect to each unit is visibly marked. <br /> 8. Once project is complete, a key for the knox box will be required. <br /> 9. All penetrations to fire wall shall be done in an approved, listed method. <br />
The URL can be used to link to this page
Your browser does not support the video tag.