My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-11197
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-11197
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2011 1:12:29 PM
Creation date
8/16/2011 1:12:26 PM
Metadata
Fields
Template:
Building Department
Company Name
MAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
10-11197
Building Department - Name
NHC-FL 115 LLC
Address
39524 CHARIOT LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX 13 -D <br /> * TABLE 118 -1 MINIMUM REQUIREMENTS (See Note 1) All Climate Zones <br /> BUILDING COMPONENT PERFORMANCE CRITERIA INSTALLED VALUES: <br /> U- Factor = 0.65 U- Factor = <br /> Windows (see Note 2): SHGC = 0.35 SHGC = 2 'A <br /> em., , CFA < =16% %of CFA = I /c+ <br /> Exterior door type Wood or insulated Type: iv vJ(g <br /> Walls — Ext. and Adj. (see Note 3): <br /> Frame R -13 R -Value = 2 `^ / r� <br /> �" Mass (see Note 3) I J Y V b 4 <br /> Interior of wall: R -6 R -Value = <br /> Exterior of wall: R-4 R -Value = <br /> xx Electric resistance heat (See Note 10) Not allowed <br /> Ceilings (see Notes 3 & 4) R =30 R -Value = 50 <br /> Floors: Slab -on -grade No requirement R -Value = �1 Q� <br /> Over unconditioned spaces (see Note 3) R -13 <br /> Hot water systems (storage type) <br /> Electric (see Note 5): 40 gal: EF = 0.92 Gallons = <br /> 50 gal: EF =0.90 EF= , /� <br /> Gas fired (see Note 6): 40 gal: EF = 0.59 Gallons = 1 f <br /> 50 gal: EF = 0.58 EF = <br /> Air conditioning systems (see Note 7) SEER = 13.0 SEER = l 7 ) <br /> Heat pump systems (see Note 8) SEER = 13.0 SEER = \I) <br /> HSPF =7.7 HSPF= 1 . 1.. <br /> Gas furnaces AFUE = 78% AFUE = <br /> 011 furnaces AFUE = 78% AFUE <br /> Programmable thermostat (see Note 10) Must be installed on all HVAC systems. Installed? Yes <br /> xx Ductwork (see Note 9) Location: V (_) <br /> Unconditioned space R-6, TESTED Uncondi o space <br /> � s ^ <br /> Conditioned space NA R -Value = <br /> Unvented attic assembly per R806.4 with insulation at the roof plane R-4.2 Test report: W <br /> Conditioned space <br /> R -Value = <br /> (No test report required) <br /> Air Handler location: a 1 l� <br /> Unconditioned attic or garage Requires test report Location: r <br /> Conditioned space or Test report: (V <br /> Unvented attic assembly per R806.4 with insulation at the roof plane No duct test required <br /> (1) Each component present in the As -Built home must meet or exceed each of the applicable performance c riteria in order to comply with this code using this method; oth- <br /> erwise Method A compliance must be used. <br /> xx (2) Windows and doors qualifying as glazed fenestration areas must comply with both the maximum U- Factor and the maximum SHGC (Solar Heat Gain Coefficient) criteria <br /> and have a maximum total window area equal to or less than 16% of the conditioned floor area (CFA), otherwise Method A must be used for compliance. Exceptions: 1. Ad- <br /> ditions of 600 square feet (56 m or less may have maximum glass to CFA of 50 percent. 2. Renovations with new windows under. 2 foot overhang whose lower edge does <br /> not extend further than 8 feet from the overhang may have tinted glazing or double -pane clear glazing. Replacement skylights installed in renovations shall be double paned <br /> or single paned with a diffuser. <br /> (3) R- Values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walls, the "interior of wall" requirement (R -6) <br /> must be met except if at least 50% of the R -4 insulation value required for the "exterior of wall" is installed exterior of, or integral to, the wall. <br /> (4) Attic knee walls shall be insulated to same level as ceilings and shall have a positive means of maintaining insulation in place. Such means may include rigid insulation <br /> board or air barrier sheet materials adequately fastened to the attic sides of knee wall framing materials. <br /> (5) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume). <br /> (6) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume). <br /> (7) For all conventional units with capacities greater than 30,000 Btu/hc For Small -Duct, High - Velocity units, Space Constrained units, and units with capacities less than <br /> 30,000 Btu/hr see Table 13- 607.AB.3.2A of the Florida Building Code, Building, or Table N1107.AB.3.2A of the Florida Building Code, Residential. <br /> (8) For all conventional units with capacities greater than 30,000 Btu/hr. For Small -Duct, High- Velocity units, Space Constrained units, and units with capacities less than <br /> 30,000 Btu/hr see Table 13- 607.AB.3.2B of the Florida Building Code, Building, or Table N1107.A8.3.2B of the Florida Building Code, Residential. <br /> (9) All ducts and air handlers shall be either located in conditioned space or tested by a Class 1 BERS rater to be "substantially" leak free. "Substantially leak free" shall mean <br /> distribution system air leakage to outdoors no greater than 3 cfm per 100 square feet of conditioned floor area at a pressure differential of 25 Pascal (0.10 In. tic.) across the <br /> x entire air distribution system, including the manufacturer's air handler enclosure. Exception: New or replacement ducts installed onto an existing air distribution system as <br /> part of an addition or renovation. Such ducts shall either be insulated to R -6 or be installed in conditioned space. <br /> xx 10) The prohibition on electric resistance heat and the requirement for programmable thermostats do not apply to additions, renovations, and new heating systems installed <br /> in existing buildings. <br /> TABLE 11B -2 MINIMUM REQUIREMENTS FOR ALL PACKAGES CHECK <br /> COMPONENTS SECTION REQUIREMENTS <br /> Exterior Joints & Cracks ' N1106.AB.1.2 To be caulked, gasketed, weather- stripped or otherwise sealed. <br /> Exterior Windows & Doors N1106.AB.1.1 Max .3 cfm/sq.ft. window area: .5 cfm/sq.ft. door area. / <br /> Sole & Top Plates N1106.AB.1.2.1 Sole plates and penetrations through top plates of exterior walls must be sealed. 1/ <br /> Recessed Lighting N1106.AB.12.4 Type IC rated with no penetrations (two alternatives allowed). <br /> Multistory Houses N1106AB.12.5 Air barrier on perimeter of floor cavity between floors. <br /> Exhaust Fans N1106AB.1.3 Exhaust fans vented to unconditioned space shall have dampers, except for combustion devices with integral <br /> exhaust ductwork. <br /> Water Heaters N1112.AB 3 Comply with efficiency requirements in Table N1112AB.3. Switch or clearly marked circuit breaker electric or cutoff <br /> (gas) must be provided. External or built -in heat trap required for vertical pipe risers. <br /> Spas & heated pools must have covers (except solar heated). Noncommercial pools must have a pump timer. Gas <br /> Swimming Pools & Spas N1112.AB2.3.4 spa & pool heaters must have minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum <br /> COP of 4.0. <br /> Hot Water Pipes N1112.AB.5 Insulation is required for hot water circulating systems (including heat recovery units). <br /> Shower Heads N1112.AS.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at BO psiq. <br /> HVAC Duct Construction, All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated <br /> N1110.AB and installed in accordance with the criteria of Section N1110.AB. Ducts in attics must be insulated to a minimum of ✓ <br /> Insulation & Installation R -6. <br /> HVAC Controls N1107AB2 Separate readily accessibble manual or automatic thermostat for ehch system. <br /> 13 -D.24 2007 FLORIDA BUILDING CODE — BUILDING <br />
The URL can be used to link to this page
Your browser does not support the video tag.