Laserfiche WebLink
A S and E, Inc. 24710 State Road 54 (813) 948 -2812 <br /> • Lutz, FI 33559 Fax: (813) 949 -2016 <br /> • <br /> Name: Apple Signs Project Physical Therapy <br /> Wind Speed 130 mph All Wind Loads meet 2009 Supplement with the <br /> • <br /> Mean Height 60 ft 2007 Florida Building Code <br /> Wind Code ASCE 7 -05 Exposure C Importance Factor 1 <br /> Wind Pressure (WP) 41.56 psf <br /> Shape Factor (SF) 1.30 Total Pressure = WP *SF 54.02 psf <br /> RtlifF1/11 DATE <br /> Letter Height (in) 1 ft 2 in Co itiec�tibrt H - <br /> Letter Width (in) 10 ft 0 in use Iriegilfturnoli ia. ed thru bolts <br /> Area 11.667 sq ft with minimum 2" square ti structural 2x4 <br /> wood blocking b/w studs or structural steel framing <br /> Number of Bolts 4 with steel angle blocking or structural normal - <br /> weight concrete backing. <br /> Shear Value 110 lbs <br /> Tension Value 700 lbs <br /> Shear per bolt = Area * 10 psf 29.17 lbs <br /> Tension per bolt = Pressure * Area 157.56 lbs <br /> Bolt Value =Shear per bolt / Shear Value + Tension per Bolt / Tension Value <br /> IBolt Value 0.49 < 1.00 O.K. 1 <br /> General Notes: Connection design only. All wind Toad calculations <br /> based on code reference section 1609, which references ASCE 7. <br /> Shape factor are determined per ASCE 7. If site conditons differ <br /> from stated reference contact A S and E, Inc. <br /> 1 (16) <br /> Robert W. Wall, PE <br /> FI Reg #46021 <br />