My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10382
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-10382
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2011 1:25:00 PM
Creation date
8/16/2011 1:22:03 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-10382
Building Department - Name
PILE,HAROLD & UNA
Address
39055 9TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 1100B -08 <br /> TABLE 11B -1 MINIMUM REQUIREMENTS (See Note 1) All Climate Zones <br /> BUILDING COMPONENT PERFORMANCE CRITERIA INSTALLED VALUES: <br /> Windows (see Note 2): U- factor = 0.65 U- factor= . (05 <br /> SHGC = O. 35 SHGC= • <br /> % CFA <= 16% % of CFA= 3 i ?p <br /> Exterior door type _ Wood or insulated Type: .144 w(A. lid_ <br /> Walls — Ext. and Adj. (See Note 3): <br /> Frame R -13 R -value = K • 1 ] EKt <br /> Mass <br /> Interior of wall: R -6 R -value = etc) .Mi. <br /> Exterior of wall: R -4 . R -value = <br /> Ceilings (see Notes 3 & 4) R -30 R- value = 30 <br /> Floors: <br /> Slab -on -grade No requirement �I <br /> Over unconditioned spaces (see Note 3) R -13 R -value = <br /> Hot water systems (storage type) <br /> Electric (see Note 5): 40 gal: EF = 0.92 Gallons = ,4/. <br /> 50 gal: EF = 0.90 EF = <br /> Gas fired (see Note 6): 40 gal: EF = 0.59 Gallons = <br /> 50 gal: EF = 0.58 EF = <br /> Air conditioning systems (see Note 7) SEER = 13.0 SEER = <br /> Heat pump systems (see Note 8) SEER = 13.0 HSPF = 7.7 SEER =' HSPF_ <br /> Gas furnaces AFUE = 78% AFUE _ gl <br /> Oil furnaces AFUE = 78% AFUE = N/A <br /> Programmable thermostat Must be installed on all HVAC systems Installed?rAisr Yes No <br /> Ductwork (see Note 9) Location: <br /> Unconditioned space R -6, Tested Unconditioned space <br /> R- value= // <br /> Test report"' <br /> Conditioned space NA Conditioned space <br /> Unvented attic assembly per R806.4 with R-4.2 R -value = <br /> insulation at the roof plane (No test report required) <br /> Air Handler location: Location: <br /> Unconditioned attic or garage Requires test report Test rep U <br /> Conditioned space or WA- <br /> Unvented attic assembly per R806.4 with No duct test required . <br /> insulation at the roof plane <br /> (1) Each component present in the As -Built home must meet or exceed each of the applicable performance criteria in order to comply with this code <br /> using this method; otherwise.Method A compliance must be used. <br /> (2) Windows and doors qualifying as glazed fenestration areas must comply with both the maximum U- Factor and the maximum SHGC (Solar Heat Gain <br /> Coefficient) criteria and have a maximum total window area equal to or less than 16 % of the conditioned floor area (CFA), otherwise Method A must be <br /> used for compliance. Exception: Additions of 600 square feet (56 m or less may have maximum CFA of 50 percent. <br /> (3) R- Values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walls, the interior (Int) <br /> requirement must be met unless at least 50% of the insulation value is on the exterior (Ext) or integral to the wall. <br /> (4) Attic knee walls shall be insulated to same level as ceilings and shall have a positive means of maintaining insulation in place. Such means may <br /> include rigid insulation board or air barrier sheet materials adequately fastened to the attic sides of knee wall framing materials. <br /> (5) For other electric storage volumes, minimum EF = 0.97 - (0.00132 * volume) <br /> (6) For other natural gas storage volumes, minimum EF = 0.67 - (0.0019 * volume) <br /> (7) For all conventional units with capacities greater than 30,000 Btu /hr. For Small -Duct, High - Velocity units, Space Constrained units, and units with <br /> capacities less than 30,000 Btu/hr see Table 13- 607.AB.3.2A of the Florida Building Code, Building, or Table N1107.AB.3.2A of the FBC- Residential. <br /> (8) For all conventional units with capacities greater than 30,000 Btu /hr. For Small -Duct, High - Velocity units, Space Constrained units, and units with <br /> capacities less than 30,000 Btu /hr see Table 13- 607.AB.3.2B of the Florida Building Code, Building, or Table N1107.AB.3.2B of the FBC-Residential. <br /> (9) All ducts and air handlers shall be either located in conditioned space or tested by a Class 1 BERS rater to be "substantially" leak free. <br /> "Substantially leak free" shall mean distribution system air leakage to outdoors no greater than 3 cfm per 100 square feet of conditioned floor area at a <br /> pressure differential of 25 Padc2l (0.10 in. w.c.) across the entire air distribution system, including the manufacturer's air handler enclosure. <br /> TABLE 11B -2 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Exterior joints & cracks N1106.AB.1.2 To be caulked, gasketed, weather - stripped or otherwise sealed. <br /> Exterior windows & doors N1106.AB.1.1 Max. 0.3 cfrn/sq.ft. window area; 0.5 cfm /sq.ft. door area. l/ <br /> Sole & top plates N1106.AB.2.1 Sole plates and penetrations through top plates of exterior walls must be sealed. t / <br /> Recessed lighting N1106.AB.1.2.4 Type IC rated with no penetrations (two alternatives allowed) <br /> Multistory houses N1106.AB,1.2.5 Air barrier on perimeter of floor cavity between floors. <br /> Exhaust fans N1106.AB.1.3 Exhaust fans vented to unconditioned space shall have dampers, except for combustion <br /> devices with integral exhaust ductwork. <br /> Water heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.AB.3. Switch or clearly marked <br /> circuit breaker electric or cutoff (gas) must be provided. External or built -in heat trap <br /> required for vertical pipe risers. <br /> Swimming pools & spas NI112.AB.2.3.4 Spas & heated pools must have covers (except solar heated). Noncommercial pools <br /> must have a pump timer. Gas spa & pool heaters must have minimum thermal efficiency <br /> of 78 %. Heat pump pool heaters shall have a minimum QOP of 4.0. <br /> Hot water pipes N1112.AB.5 Insulation is required for hot water circulating systems (including heat recovery units). <br /> Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 psig. <br /> HVAC duct construction, N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> insulation & installation attached, sealed, insulated and installed in accordance with the criteria of Section `// <br /> N1110.AB. Ducts in attics must be insulated to a minimum of R-6. <br /> HVAC controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. <br /> 13 -D.24 2007 FLORIDA BUILDING CODE — BUILDING <br />
The URL can be used to link to this page
Your browser does not support the video tag.