Laserfiche WebLink
FIG. 92 Beam Clamps /,M/Stal' <br /> Fire Products Division of Anvil' International <br /> t )AN1✓IL Universal C -type Clamp (Standard Throat) Submittal Sheet <br /> SIZE RANGE: 3 /8 and ih" <br /> MATERIAL: Ductile iron, hardened steel cup point set screw and locknut. <br /> FINISH: Plain or Galvanized <br /> SERVICE: Recommended for use under roof installations with bar joist type construction, or <br /> for attachment to the top or bottom flange of structural shapes where the vertical hanger rod <br /> is required to be offset from the edge of the flange and where the thickness of joist or flange _._ .. <br /> does not exceed 3 /4 " - .: <br /> APPROVALS: Complies with Federal Specification A- A -1192A (Type 19 & 23), <br /> WW -H -171 -E (Type 23) and MSS -SP -69 (Type 19 & 23). UL, ULC Listed and FM Approved. <br /> HOW TO SIZE: Size of clomp is determined by size of rod to be used. <br /> INSTALLATION: Follow recommended set screw to ue values r t <br /> i <br /> MSS -SP -69 (See table on page PF 212) <br /> FEATURES: \/ <br /> • They may be attached to horizontal flanges of structural members in either the top beam or 11•0 <br /> bottom beam positions. <br /> • Secured in place by a cup - pointed Set Screw tightened against the flange. A Jam Nut is <br /> provided for tightening the Set Screw against the Body Casting. <br /> • Thru tapping of the body casting permits extended adjustment of the threaded rod. + �H c <br /> E F <br /> • Can be used with Fig 89X retaining clip for seismic applications. AT LEAST ONE <br /> l� <br /> G 141111111 FULL THREAD OF ' <br /> ROD MUST I <br /> BE ExPOSED <br /> 3,,,, 1 <br /> 3 <br /> D <br /> BODY <br /> CASTING <br /> 1111 = GO <br /> JAM -NUT �� --I.- -..—A <br /> Oa MEI <br /> SET SCREW <br /> FIG. 92 <br /> Rod Size Set Screw Max Loads • <br /> A Size Top Bottom Weight E D E F G H <br /> 3 3A, 500 250 0.34 1 1 9 16 1346 3 /e 1 /2 <br /> 1 1/2 950 760 0.63 1 113/16 1/2 1 2 /16 2 <br /> ■ Maximum temperature of 450° F <br /> PROJECT INFORMATION: APPROVAL STAMP: <br /> Project: <br /> Date: I Phone: <br /> Architect / Engineer: <br /> Contractor: <br /> Address: <br /> Notes 1: <br /> Notes 2: <br /> Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com <br /> Anvil® Pipe Hangers & Supports For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, (z)ixiuviL <br /> REV. 03.03.06009 go to www.anvilstar.com or contact your local AnvilStar representative <br /> ■ <br />