David Johnson <br /> 6803 Oak Crest Way <br /> Electrical Notes <br /> 1999 Electrical Code <br /> 210- 8(a)(3): Outdoor receptacles shall be GFCI protected <br /> 210- 8(a)(6): Receptacles that serve kitchen counters shall be GFCI <br /> protected <br /> 210- 11(c)(3): Bathroom receptacle circuits shall have no other outlets <br /> 210- 52(e): Receptacles shall be located at both the front and rear of the <br /> dwelling <br /> 410- 57(b): Receptacles in wet locations shall have an enclosure that <br /> provides protection from the weather when closed or open <br /> CABO 316.1: Smoke detectors shall be installed in each sleeping room, <br /> outside of each sleeping area in the immediate vicinity of the <br /> bedrooms <br /> CABO 316.2: Required smoke detectors shall be supplied by A/C current <br /> and have battery backup <br /> 03/18/02 <br /> 8:46 AM <br />