My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38461 CR 54 EAST
Zephyrhills
>
Building Department
>
Building Plans
>
38461 CR 54 EAST
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2011 11:36:11 AM
Creation date
8/29/2011 11:32:30 AM
Metadata
Fields
Template:
Building Plans
Street #
38461
Location
CR 54 EAST
Description
EAST 54 MINI STORAGE
Owner
BOLENDER,JOHN
Building Plans - Permit #
PERMIT # 2370-73
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />N <br />Ln <br />a <br />m <br />Ln <br />U <br />W <br />De <br />U <br />W <br />m <br />O <br />STEP TRIM — <br />(SEE DRAWING <br />NO. ERC71OX <br />1 <br />Z <br />0 <br />ROOF PANELS <br />(SEE DRAWING <br />NO. ERC41OX <br />PP <br />rfl, <br />° <br />I I <br />� <br />WBETCO,INC. <br />SHEET TITLE: <br />Sculptured Rake Trim, Extended <br />G and Downspouts <br />REVISED GUTTER JOINT DETAIL <br />10/9/02 <br />JCM <br />CHANGED INSIDE END CAP TO OUTSIDE END CAP <br />12/13/00 <br />BDL <br />P.O. BOX 1650 <br />STATESVILLE, NO 28687 <br />` , <br />REVISED DOWNSPOUTS <br />07/10/00 <br />JCM <br />DRAWN BY: <br />CJG <br />A 0 <br />�7 <br />DRAWING NUMBER: <br />ERC505X <br />GENERAL REVISIONS <br />03/19/99 <br />• 1 <br />SALE: <br />NTS <br />DATE: <br />4/7/98 <br />REVISIONS <br />DATE <br />1 <br /># 14 x 7/8" SDF (PP) <br />(PART N0. F14011) <br />0 30" O.C. <br />SCULPTURED RAKE TRIM <br />� t 2 x 7/8" SDF <br />ART NO. F12017) <br />NOTE: DISTANCE BETWEEN ROOF 30" O.C. ROOF PANEL <br />PANEL & HEADER VARIES 16" COVERAGE <br />#14 x 7/8" SDF (PP) 12 x 7/8" SDF <br />ART NO <br />(PART N0. F14011 I P F12017) <br />0 30" O.C. _ _ I 3/8" DIA. x 3/4" LONG <br />BOLT, NUT, FLATWASHER <br />HEADER COLUMN &STARWASHER <br />BRACE "ZEE" <br />SECURE OUTSIDE END <br />TO INSTALL DOWNSPOUT " <br />OUTSIDE OF /BEND " F I LAPS BOTTOM <br />DOWN; x TO SECURE END CAP WITHIN CORNER BOXES FLAP WITH #14 <br />STEP 4: AFTER LAP AND RIVET INSTALLATION, SDF (PP) (SEE DETAIL) <br />APPLY DOW CORNING 799 SILICONE <br />SEALANT (CLEAR) (PART NO. M20050) <br />(NOTE: GUTTER MUST BE CAULKED ALONG <br />ENTIRE INSIDE EDGE OF GUTTER LAP PERIMETER <br />AFTER GUTTER SECTIONS ARE INSTALLED) GUTTER <br />STEP 3: <br />LAP GUTTER SECTIONS AT LEAST 3" , <br />AND INSTALL 1/8 POP RIVET - 3 1/4" - ►�- <br />2" FROM EDGE OF OUTSIDE SECTION BEND LINE <br />" <br />12 x 1" SDF <br />TYP. 3 PER PAN) <br />— SIDEWALL COLUMN <br />HEADER <br />DOW CORNING 799 <br />ILICONE SEALANT (CLEAR) <br />PART NO. M20050 <br />#14 x 7/8" SDF (PP) <br />(PART NO. F14011)) <br />(311 <br />DOWNSPOUT STRAP <br />3 LAP T <br />CLEAR CAULK AS SHOWN Ld <br />►.t..� .. I � BELOW IN STEP 2 ? <br />SECTION AT RAKE OUTSIDE SECTION OF GUTTER—/ <br />SECTION AT GUTTER LAP JOINT <br />SCULPTURED RAKE TRIM <br />NOTE: DISTANCE BETWEEN ROOF <br />PANEL & HEADER VARIES <br />#14 x 7/8" SDF (PP) <br />/r @ (PART N0. F14011) <br />30" O.C. <br />I <br />ROOF PANEL <br />16" COVERAGE <br />tp, 2 x 7/8" SDF <br />AR T NO. F12017) <br />ANGLE SA -2 30" O.C. <br />(2 1/2" x 2 1/2" x 120") ?- <br />I 12 x 7/8" SDF <br />14 x 7/8" SDF pP) PART NO. F12017) <br />PART NO. F140115 3/8" DIA. x 3/4" LONG <br />0 30" O.C. BOLT, NUT, FLATWASHER <br />& STARWASHER <br />HEADER COLUMN n <br />BRACE "ZEE" `1 <br />SECTION AT RAKE r <br />AND ANGLE SA-- 2 <br />I N <br />1/8" POP RIVETS <br />(PART NO. F13046) <br />(3 PER LAP) <br />2" FROM EDGE <br />3" FLANGE N <br />6 <br />I <br />I <br />I <br />J <br />0 <br />INSIDE SECTION OF m <br />GUTTER <br />INSIDE SECTION <br />CAP TO GUTTER WITH <br />A GENEROUS BEAD OF <br />SILICONE SEALANT <br />(CLEAR) (#M20050)... 50)... <br />L 7/8" SDF (PP) � <br />) PART N0. F14011) <br />REQUIRED AT <br />OUTSIDE END CAP <br />- GUTTER <br />7" <br />FIELD DRILL (3) 1/2" DIA. <br />HOLES AT 4" ABOVE <br />BOTTOM OF GUTTER <br />� 14 x 7/8" SDF (PP) <br />4) (PART NO. F14011) <br />REQUIRED AT TRANSITION <br />CORNER BOX <br />�- GUTTER <br />n. HEADER <br />1' -6" <br />3/4" 1 <br />TYPICAL DOWNSPOUT <br />OPENING <br />STEP 1: NOTCH 1" DEEP x 1/2" VEE CUTS <br />AT 4 LOCATIONS AS SHOWN AND NOTCH -OUT 3" <br />° STEP 2 FLANGE SECTION AT BACK OF GUTTER <br />: <br />' APPLY DOW CORNING 799 SILICONE SEALANT PAVING LINE <br />(CLEAR) (PART NO. M20050) 1" FROM EDGE <br />(NOTE: GUTTER MUST BE CAULKED <br />OUTSIDE SECTION ALONG ENTIRE INSIDE PERIMETER AS <br />SHOWN TO PROVIDE A TIGHT SEAL) REVISED GUTTER LAP DETAIL 3/20/03 JCM <br />REILw s, � F - OR <br />0ATL' AUG 19 2003 <br />BY /! <br />TYPICAL GUTTER LAP JOINT <br />° <br />I I <br />� <br />I <br />I <br />I <br />J <br />0 <br />INSIDE SECTION OF m <br />GUTTER <br />INSIDE SECTION <br />CAP TO GUTTER WITH <br />A GENEROUS BEAD OF <br />SILICONE SEALANT <br />(CLEAR) (#M20050)... 50)... <br />L 7/8" SDF (PP) � <br />) PART N0. F14011) <br />REQUIRED AT <br />OUTSIDE END CAP <br />- GUTTER <br />7" <br />FIELD DRILL (3) 1/2" DIA. <br />HOLES AT 4" ABOVE <br />BOTTOM OF GUTTER <br />� 14 x 7/8" SDF (PP) <br />4) (PART NO. F14011) <br />REQUIRED AT TRANSITION <br />CORNER BOX <br />�- GUTTER <br />n. HEADER <br />1' -6" <br />3/4" 1 <br />TYPICAL DOWNSPOUT <br />OPENING <br />STEP 1: NOTCH 1" DEEP x 1/2" VEE CUTS <br />AT 4 LOCATIONS AS SHOWN AND NOTCH -OUT 3" <br />° STEP 2 FLANGE SECTION AT BACK OF GUTTER <br />: <br />' APPLY DOW CORNING 799 SILICONE SEALANT PAVING LINE <br />(CLEAR) (PART NO. M20050) 1" FROM EDGE <br />(NOTE: GUTTER MUST BE CAULKED <br />OUTSIDE SECTION ALONG ENTIRE INSIDE PERIMETER AS <br />SHOWN TO PROVIDE A TIGHT SEAL) REVISED GUTTER LAP DETAIL 3/20/03 JCM <br />REILw s, � F - OR <br />0ATL' AUG 19 2003 <br />BY /! <br />TYPICAL GUTTER LAP JOINT <br />REVISED FASTENER SIZE <br />1/15/03 <br />JCM <br />WBETCO,INC. <br />SHEET TITLE: <br />Sculptured Rake Trim, Extended <br />G and Downspouts <br />REVISED GUTTER JOINT DETAIL <br />10/9/02 <br />JCM <br />CHANGED INSIDE END CAP TO OUTSIDE END CAP <br />12/13/00 <br />BDL <br />P.O. BOX 1650 <br />STATESVILLE, NO 28687 <br />` , <br />REVISED DOWNSPOUTS <br />07/10/00 <br />JCM <br />DRAWN BY: <br />CJG <br />A 0 <br />�7 <br />DRAWING NUMBER: <br />ERC505X <br />GENERAL REVISIONS <br />03/19/99 <br />FOX <br />SALE: <br />NTS <br />DATE: <br />4/7/98 <br />REVISIONS <br />DATE <br />BY <br />CORNER BOX <br />OUTSIDE END CAP <br />SCULPTURED <br />RAKE TRIM <br />#14 x 7/8" SDF (PP) <br />(PART NO. F14011)) <br />CUT i 3 1/4" <br />I I <br />I <br />I <br />I I <br />BEND LI E <br />I-►I 2 1/2" (DOWNSPOUT <br />14 x 7/8" SDF <br />GUTTER w/ NEOPRENE WASHER (PART NO. F14010 <br />3 , PER PANEL AT GUTTER ATTACHEMENT WIDE OM30020)IC (CONTINUOUS) <br />T (PART NO <br />G <br />4" DOW 791 BRONZE CAULK <br />® EAVE (PART# M20055) <br />i <br />/ 5" <br />2" <br />I <br />�r <br />� 14 x 7/8" SDF (PP) <br />4) (PART NO. F14011) <br />REQUIRED AT PEAK BOX <br />—' 1 1/2" <br />PEAK BOX DETAIL Ir 3.. <br />11/4' , APPROX. <br />3 "— �— ROOF OVERHANG SHOULD BE EQUAL <br />G CLIP #14 x 7/8" SDF (pP)EACH EAVE) <br />22ga (7" L�) w/ NEOPRENE WASHER <br />4' -0" O. <br />DOW CORNING 799 <br />C. \\ (PART NO. F14011) <br />
The URL can be used to link to this page
Your browser does not support the video tag.