Laserfiche WebLink
David Johnson <br /> 6819 <br /> Oak Crest Way <br /> Electrical Notes <br /> 1999 Electrical Code <br /> 210- 11(c)(3): Bathroom receptacle circuits shall have no other outlets <br /> 210- 52(c)(1): No point in a wall shall be more than 2' from an outlet <br /> 210- 52(e): Receptacles shall be located at both the front and rear of the dwelling <br /> 210- 8(a)(2): Garage receptacles shall be GFCI protected <br /> 210- 8(a)(3): Outdoor receptacles shall be GFCI protected <br /> 210- 8(a)(6): Receptacles that serve kitchen counters shall be GFCI protected <br /> 240 -24: Location of panel <br /> 250- 50(c): Footer steel shall be grounded <br /> 410- 57(a): Receptacles in damp locations may have an enclosure that provides protection <br /> from the weather only when closed <br /> 410- 57(b): Receptacles in wet locations shall have an enclosure that provides protection <br /> from the weather when closed or open <br /> CABO 316.1: Smoke detectors shall be installed in each sleeping room, outside of each <br /> sleeping area in the immediate vicinity of the bedrooms <br /> CABO 316.2: Required smoke detectors shall be supplied by A/C current and have battery <br /> backup <br /> 03/18/02 <br /> 2:17 PM <br />