Electrical Notes <br /> 2002 Electrical Code <br /> Ryman Construction <br /> Lot #34 Highland Loop <br /> 250.66: Grounding electrode conductor shall be sized according to Table 250.66 <br /> 210.52(E): For a one - family dwelling and each unit of a two- family dwelling that is at grade level, at <br /> least one receptacle outlet accessible at grade level and not more than 2.0mm (6 '/') <br /> above grade shall be installed at the front and back of the dwelling. <br /> 406.8(A): A receptacle installed outdoors in a location protected from the weather or in other damp <br /> locations shall have an enclosure for the receptacle that is weatherproof when the <br /> receptacle is covered (attachment plug cap not inserted and receptacle covers closed). <br /> 406.8(B)(1): 15- and 20- ampere, 125- and 250 -volt receptacles installed outdoors in a wet location <br /> shall have an enclosure that is weatherproof whether or not the attachment plug cap is <br /> inserted. <br /> 422.18(A): Ceiling- suspended (paddle) fans that do not exceed 16 kg (35 lb) in weight, with or <br /> without accessories, shall be permitted to be supported by out let boxes identified for <br /> such use and supported in accordance with 314.23 and 314.27. <br /> 07/31/02 <br /> 12:02 PM <br />