GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE FLORIDA BUILDING CODE 2001. <br />ARKAY ENGINEERING INCs A REGISTERED LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING CO MPANYs HAS APPLIED ' RATIONAL ANALYSIS' FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS SHALL ME DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS <br />FLOORO, <br />LIVE LOADS - 40 P.B.F, <br />DEAD LOADS - 10 P.B.F. <br />GARAGE SLABS <br />LIVE LOADS - 50 P.&F, <br />DEAD LOADS - 10 P.S.F. <br />ROOFs <br />LIVE LOADS (TRUSS TOP CORD) - 20 <br />DEAD LOADS (TRUSS TOP CORD) - 10 P.B.F. 18 P.S,F, WHEN TILE ROOF INSTALLED <br />LIVE LOAD (TRUSS BOTTOM CORD) - 10 P.S.F. <br />WINOS A88UMED TRUSS SELF WEIGHT ( DEAD LOAD) - 1 P.B,F, <br />BUILDING 16 DESIGNED TO CONFORM TO ASCE 1 -98, CHAPTER 6s PER FLORIDA BUILDING <br />CODE 2001 SECTION 1606.1.1 <br />WIND DESIGN ASSUMPTIONSs <br />BUILDING EXPO6URE - B <br />BUILDING IMPORTANCE FACTOR ■ 1.0 ( CATEGORY II ) <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENTS COEFFICIENT ■ 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT ■ . / - 0,18 <br />Site WIND SPEED INFORMATION STATED ON PLANS <br />TYPE 5 CONSTRUCTION <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL SEARING CAPACITY OF <br />2000 P.B.F.( MINIMUM ) THE CONTRACTOR/PROPERTY OWNER 16 RESPONSIBLE FOR VERIFYING <br />THAT THE SOIL ON THE SITE 16 PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN <br />SUPPORT A 2000 P.S.F. FOUNDATION LOADING <br />ARKAY ENGINEERING INCs A REGISTERED LICENSED FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANYs DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION <br />SITE NOR PERFORMING ANY SOIL TESTING <br />ARKAY ENGINEERING INC SHALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT <br />THE BUILDING LOADS <br />FOUNDATION 4 SLA5 - ON- GRADE NOTES : <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS:, <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, $HALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.S.F. FOUNDATION LOADING. $LAM <br />SHALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED <br />AND TERMITE POISONIED 801E <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2500 P.B.F. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR <br />0 5 REBAR , 30" FOR f6 REBAR / 35" FOR •1 RE13AR <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT 6TEMWALI- HEIGHT BABE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSE ARE REOUIREED <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL ME EXPOSED AND A <br />STRING 6TRECTEED FROM MARKER TO MARKER TO VERFiY REQUIRED SET BACKS <br />MASONRY WALLSs <br />CONCRETE MASONRY UNIT SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH A6TM C -90 <br />AND 614ALL HAVE MINIMUM F'M of 15o0 P.S.I. <br />MORTAR SHALL CONFORM TO ASTMC - 210 AND $HALL BE EITHER TYPE M OR 6 <br />REINFORCING STEEL SHALL DE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTMA -615. LAP SPLICES WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 0 5 REBAR <br />30' FOR 0 6 REBAR AND 35' FOR 0 1 REMAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/8' PLACED AT 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF <br />2000 P.S.I: ( WHEN TESTED PER ASTM C -1019 ) <br />PROVIDE CLEAN OUT OPENING$ ( 12 $0. IN. ) IN CELL& CONTAINING SPLICED REINFORCEMENT. WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT <br />ROOFING 4 FLASHING& <br />ROOFING SYSTEM AND FLASHING AS STATED IN PLANS MUST CONFORM TO CHAPTER 15 OF THE FLORIDA <br />BUILDING CODE 200L FLASHING SPECIFIC SECTION 15013.9 CONTRACTOR OR OWNER MUST PROVIDE WITH <br />PLANS SPECIFIC PRODUCT INFORMATION DETAILING INSTALLATION OF PRODUCT TO MEET WIND DESIGNS <br />OF TH16 SET OF DRAWINGS. <br />TIMBER MATERIALS= <br />ALL TIMBERS MATERIALS 6HALL BE AS FOLLOWS, <br />LVL SEAMS 614ALL BE (1.90) MCALLISTER LVL MATERIALS MANUFACTURED BY TRUSS J018T <br />MACMILLAN (OR EQUAL) <br />LUMBER UTILIZED IN BOTTOM PLATE, TOP PLATER ,POST, STUDS PACKS AND BEAMS <br />SHALL BE +2 YELLOW PINE (OR BETTER) <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL 3E 0 2 SPRUCE (OR BETTER) <br />ALL OTHER STUDS SHALL BE "STUD GRADE" SPRUCE SPACE 16" OC. ALL SPLICES AT <br />TOP PLATE MUST BE MINIMUM WO" AND NAILED 4" or, WITH 120 COMMON NAILS <br />SOIL TERMITE TREATMENTS <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION <br />OACKFILLING t COMPACTING ARE COMPLETE (PER FMC 1816,1,) <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE TREATED <br />( INCLUDING ANY 150XED OR FORMED ARM") (PER FBC 18161.2.) <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMAMENT METAL OR PLASTIC FORMS. PERMAMENT FORMS MAST BE OF AN ADEQUATE <br />SIZE t DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE INITIAL TREATMENT <br />(PER FMC 1816,113) . <br />A MINIMUM Co MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR 15ARRIER PLACEMENT, RE TREATMENT SHALL <br />BE REQUIRED (PER FMC 1816.1.4) <br />ALL BUILDINGS ARE REQUIRED TO HAVE A PRE CONSTRUCTION TERMITE TREATMENT <br />(PER FBC181611.1) <br />AFTER ALL WORK 16 COMPLETE ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELO AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS <br />(PER FOC 2303,63) <br />NO WOOD VEGETATION, STUMPS, CARDBOARD, TRASH, ETC, SHALL DE BURIED WITHIN 15' O" <br />OF ANY BUILDING OR PROPOSED BUILDING (PER FDC 23031.4) <br />ANY CONCRETE OVER POUR MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR $OIL TREATMENT (PER FMC 1816.63) <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12' OF THE *TRUCTURO SIDE WALLS (PER FBC 1816.1.6) <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL DIE INSTALLED AFTER CONSTRUCTION 18 <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL 016TURDED AFTER THE <br />VERTICAL BARRIER 16 APPLIED, SHALL BE RETREATED (PER FMC 1816.1.6) <br />IRRIGATION / SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT ME <br />INSTALLED WITH 12 OF THE BUILDING 61DEWALL6 (PER FBC 1303.4.4) <br />CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING <br />SIDE WALLS (PER FMC 1503.4.4) <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS= PAINT AND DECORATIVE <br />CEMENTITIOUS FIN16W LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6' TO ALLOW FOR INSPECTION FOR FUTURE <br />TERMITE INFESTATIONS (PER FBC 1403.1.6) <br />A " CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL Be ISSUED. THE CERTIFICATE <br />SHALL STATES (PER FMC 1815.1.1) <br />° THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITE&, THE TREATMENT 16 INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT <br />OF AGRICULTURE AND CONSUMERS SERVICE& <br />A PERMAMENT SIGN THAT IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE INSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED, THE SIGN SHALL BE POSTED NEAR THE WATER <br />HEATER OR ELECTRICAL PANEL (PER FBC 104.2.6) <br />TRUSSES <br />IF THE CONTRACTOR, TRUSS MANUFACTURE OR ANY OTHER DESIGN PROFESSIONAL REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANE ARKAY ENGINEERING, INC 16 <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE <br />DESIGN INTENT PRIOR TO COMMENCEMENT OF THE PROJECT <br />I HOUR BLOCK FIRE LJALL DETAIL <br />P61- POST SHALL BE MOM) PARALLAM PSI- MATERIALS MANUFACTURES BY TRUSOJOIOT <br />MACMILLAN ( OR EQUAL), SEE P08T SUPPORT TABLE FOR LOAD VALUES. <br />EXTERIOR WALLS SHALL BE CONSTRUCTED WITH V2" PLYWOOD OR 1/16" 0.3.13. ( 2-M 'J RATING) NAILED <br />WITH 8D NAILS SPACE AT 3' OC ALONG ALL HORIZONTAL JOINT& AND EDGER, 6" OC ALONG ALL VERTICAL <br />JOINTS AND EDGES AND 12" OC ALONG ALL INTERMEDIATE $TUDB <br />AT OPENINGS 5'O" WIDE OR LARGER $TRAP HEADER BEAM TO THE HEADER STUD$ WITH (2) USP OR SIMPSON <br />LOTA24 STRAP TIES AT EACH END OF HEADER BEAM. ANCHOR BOTTOM OF HEADER STUDS TO FOUNDATION <br />WITH USP OR SIMPSON HTTI& TENSION TIE, <br />INTERIOR STUD WALLS TO BEE OF 2 X 4 0 2 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 +2 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R -11 INSULATION <br />ANCHOR WOOD SHEAR WALLS SEGMENTS TO FOUNDATION WITH SIMPSON LTT200 TENSION TIE AT EACH <br />END OF WALL SEGMENT$ AND AT ANY WALL SEGMENT INTERSECTION ( BUILDING CORNERS) <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />IF DESIRED, EQUIVALENT CONNECTOR$ MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />USP OR SIMPSON CONNECTOR& SHOWN <br />EXTERIOR WINDOWS 4 DOORS: <br />ALL EXTERIOR WINDOWS ! GLASS DOORS OR ENTRANCE DOOR SHALL BE TESTED IN ACCORDANCE WITH <br />ANSVAMMA/NWWDA 10VI82 STANDARD AND BEAR AN AMMA OR WOMA LABEL IDENTIFYING THE MANUFACTURE <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TEST OR ENGINEERED TO TRANSFER <br />1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE <br />INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE MANUFACTURE ANCHORING RECOMMENDATIONS <br />TO ACHIEVE THE DESIGN PRESSURES SPECIFIED <br />ELECTRICAL, PLUMBING, 4 MECHANICALs <br />IN ACCORDANCE WITH CHAPTER 411,003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODEs ELECTRICAL <br />PLUMBING AND MECHANICAL 6Y6TEM8 SHALL ME DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES, THE ELECTRICAL.., PLUMBING AND MECHANICAL SYSTEMS DRAWN HERON <br />ARE SASE UPON A DESIGN PROVIDED BY THE OWNER TO ADDRE66 HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOM$, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "CFI' CIRCUIT <br />2 X 0 CUT TO FIT BETWEEN TRUSSES <br />ANCHORED TO BLOCK WALL WITH <br />I/2" X 8" ANCHOR BOLTS 32" OC <br />NAIL TRUSSES ALONG BOTTOM — <br />CORD WITH 12O COMMON NAILS <br />12' OC <br />ROOF TRUSSES <br />R -19 INSULATION <br />(TYP) 1/2" GYPSUM CEILING BOARD <br />3/4' P.T. FURING STRIP AND I LAYER 5/6' TYPE <br />X DRYWALL EACH SIDE OF BLOCK WALL AND ON <br />ROOF TRUSS ABOVE FROM FLOOR TO BOTTOM OF <br />ROOF SHEATHING ABOVE <br />(2) "5 REBAR ON <br />"5 VERTICAL RODS AS <br />SHOWN ON FOUNDATION <br />PLAN <br />\ III II III (TYP) 4" CONCRETE SLAB <br />--------------- - - - - -- -- --------------------------------- - - - - -- <br />1 �- 1 <br />24" <br />ATTACH MINIMUM 3/4" P.T. BUCK STRIP <br />THAT 18 THE MINIMUM WIDTH OF YOUR <br />WINDOW FRAME USING .OS1 X 1 3/8" <br />T- NAILS MAXIMUM 10" OC <br />(TYP) 1/2" GYPSUM CEILING BOARD <br />3/4' P.T. FURING STRIP AND I LAYER 5/6" TYPE <br />X DRYWALL EACH SIDE OF BLOCK WALL AND ON <br />ROOF TRUSS ABOVE FROM FLOOR TO BOTTOM OF <br />ROOF 614EATHING ABOVE <br />SECURING WINDOW TO BUCK STRIPS PER <br />YOUR MANUFACTURES INSTRUCTION TO MEET <br />WIND LOAD AND COMPRESSION RATINGS FOR <br />YOUR JOB LOCATION, ALL ANCHOR SCREWS <br />MUST PENETRATE BLOCK WALL A MINIMUM or- <br />1 1/4" AND THERE SHALL BE A MAXIMUM 1/4" <br />SPACE BETWEEN BUCK AND WINDOW FRAME <br />ALL ELECTRICAL OUTLETS IN BEDROOM$ ! FIXTURES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />'AFT' CIRCUIT <br />SMOKE DETECTORS $HALL BE PLACE IN EACH 13E GROOM AND <br />IN HALL WAY AREAS ADJACENT TO BEDROOM AND OTHER LIVING CAULKED WINDOW PER YC <br />AREAS <br />WINDOW MANUFACTURES 6 <br />SAFETY GLAZING: RECOMMENDATIONS t0 MI <br />LOAD AND COMPRESSION <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATION FOR THE PURPOSE OF FOR YOUR JOB L OCATION <br />GLAZING <br />(1) GLAZING IN OWING DOORS, FIXED AND $LIVING PANEL OF & LIDING DOORS <br />ASSEMBLIES <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR 140T TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOM*, ISATHTU156 AND $ HWNER&, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING 16 LESS <br />THAN 60' ABOVE THE DRAIN INLET <br />(3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VORTICAL EDGE 16 WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED <br />P061TION AND W1406E BOTTOM EDGE 16 LE88 THAN 60" ABOVE THE FINISH FLOOR OR <br />WALKING SURFACE <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANES. OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE . THAT MEETS ALL OF THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 60, FT, <br />(M) BOTTOM EDGE LESS THAN 18 ABOVE? THE FLOOR <br />(C) TOP EDGE GREATER THAN 36' ABOVE THE? FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY <br />OF THE PLANE OF THE GLAZING <br />DRAFTSTOPPINGs <br />IN SINGLE FAMILY DWELLINGS, ORAFTOTOPPING$ SHALL BE PROVIDED ( PARALLEL TO THE MAIN <br />FRAMING MEMBER$) IN FLOOR / CEILING ASBEMBLIE$ SEPARATING UORA151 -3 SPACES. DRAFT6TOPPING <br />$HALL BE CONSTRUCTED OUCH THAT THE FLOOR / CEILING A88EMBLEY 1$ BROKEN UP INTO TWO OR MORE <br />APPROXIMATED AREAS WITH NO AREA GREATER THAN 500 SQ.FT, <br />ATTIC ACCESS: <br />ATTIC SPACES SHALL ME PROVIDED WITH AN INTERIOR ACCESS OPENING NOT LESS THAN <br />22 "X36 ACCESS OPENING SHALL DE ACCESSIBLE AND PROVIDE WITH A LID OR DEVICE <br />THAT 16 EA REMOVED OR OPENED, WHEN MECHANICAL E(2UIPMNT 16 INSTALLED IN <br />THE ATTIC, IT &HALL BE INSTALLED IN ACCORDANCE WITH MECHANICAL CODE. <br />ACCESS 16 NOT REQUIRED WHEN THE CLEAR HEIGHT OF THE ATTIC SPACE , MEASURED <br />AT THE ROOF PEAK 18 LESS THAN 24 <br />SIMPSON M5HA3.E:6 /11.25" HANGER <br />OR EQUAL FILL ALL NAIL HOLES TO BEAM WITH 100 X 1 1/2" TYPICAL <br />TRUSS NAILS <br />STEEL PLYCLIP$ <br />PLYWOOD NAIL PATTERN (ROOF) <br />PLYWOOD NAILED AS SHOWN 18 DESIGNED TO <br />WITH STAND MAXIMUM WIND LOAD RATING OF <br />130 MPH <br />ATTACH MINIMUM 3/4" P.T. BUCK <br />STRIP THAT 18 THE MINIMUM WIDTH <br />OF DOOR FRAME USING .091X1 3/8" <br />T- NAILS MAXIMUM 10" 00, <br />CAULK DOOR FRAME PER YOUR <br />MANUFACTURES RECOMMENDATIONS <br />BLOCK DOOR ATTACHMENT DETAIL <br />sse�bss� ass <br />17 <br />FILLED CELL (TYP)_ <br />8" CMU W/ 3000 PSI <br />CONC t LINTEL lJ/ <br />1 0 60 MIN. LAP 30" <br />3r4 A301 ANCHOR BOLT 55/8" FROM OF EDGE <br />OF BLOCK WALL WITH MIN, 6" EMBEDDED <br />IN 3000 PSI CONCRETE GROUT <br />II • <br />I I <br />II <br />I I <br />BBL 2 X 12 #2 PINE BEAM WITH ONE <br />LAYER 1/2" CDX IN CENTER <br />13M /WALL CONN <br />THE CLIENT UNDERSTAND$ THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDE]MNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) AR161NG OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />BLOCK WINDOW ATTACHMENT DETAIL <br />SECURING PREHUNG TO BUCK STRIPS <br />PER YOUR MANUFACTURES INSTRUCTIONS <br />TO MEET WIND LOADS AND COMPRESSIONS <br />RATINGS FOR YOUR J05 LOCATION. ALL <br />ANCHOR SCREWS MUST PENETRATE BLOCK <br />WALL A MINIMUM OF 1 1/4" AND THERE SHALL <br />BE A MAXIMUM 1/4" SPACE BETWEEN BUCK <br />AND DOOR JAMB <br />ICI ICI <br />ARKAY ENGINEERING INC, <br />STRUCTURAL ENGINEERS <br />RICHARD L. KIODEY P.E. <br />FLORIDA LICENSE NUMBER 31286 <br />I WER133Y CERTIFY THAT THESE! PLANS AND SPECIFICATION$ <br />WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE 2001 <br />FOR 110 MPH ( 3 SEC-ONO GUST ) WIND ZONE - 90 MPH FASTEST <br />SPED <br />O <br />N N <br />° � t3 <br />z to W <br />N U? in <br />� Q (4 <br />IL M Q <br />N ma cz <br />00 LL 03 <br />O C <br />_ V <br />N <br />W N Q <br />Z 0 Q ul) Z <br />UJI <br />OG G v O <br />ce <br />C � <br />Ej„ X11 <br />z =� <br />z �- <br />LL <br />1~ z =� <br />s n A <br />(y _ <br />-4 <br />} <br />O <br />.Q <br />O z A <br />4 <br />a <br />(Q N (� <br />z o <br />Q <br />v tc <br />; <br />1- <br />r� �h"A <br />Q <br />UNIT * 1 <br />LIVING 816,0 <br />ENTRY 42,6 <br />TOTAL 859.6 <br />LIVING 800.0 <br />ENTRY 20.0 <br />TOTAL x20.0 <br />TOTAL 161$.6 <br />FIG <br />4OF4 <br />ARKAY N 753 I <br />