Laserfiche WebLink
10" <br />1"0 SCH. 80 PVC <br />(AS -1 THROUGH AS -29) <br />l llrrr—= = = =__= <br />l r - — - - -- 1 1 Fr — _---------------------- <br />IIII -=-= = I I I I I I Fr - - - -- ------------ - - - - -- <br />11111 II111 � _= _ - =_ = 1 1 1 1 1 1 1 1 <br />F ------------------- <br />1111 - -= 1 1 1 1 1 1 1 1 I l r ------------ - - - - -- 2 "0 SCH. 40 PVC <br />= -- -- - — — ---- — — — — — - (SVE -1 THROUGH SVE -19) <br />III II II II II IIIIIIIIIrr� __ =1 1 1 1 1 1 1 1 1 1 1 1 r -------------- <br />10 III II II I I II I I I III I I I III I F f � =1 11 1 I I I 1 r-------- - - - - -- <br />r ------- - - - - -- <br />3 5 I II II I I I - - I I I I I I I I I I I I I 1 1 1 � _ _---- _ ---- -_ <br />I --- - - - - -- <br />AIR SPARGE <br />T �iTT <br />PROCESS & INSTRUMENTATION EQUIPMENT SPECIFICATIONS <br />PI ASW1 <br />— PI ASW29 <br />2.5" S.S LIQUID— FILLED 0 -30 PSI PRESSURE GAUGE <br />FI ASW1 <br />— FI ASW29 <br />DWYER MODEL RMC -121 10" SCALE, 1 -10 SCFM <br />PI ASV <br />— PI ASV3 <br />2.5" S.S LIQUID— FILLED 0 -30 PSI PRESSURE GAUGE <br />TI ASV — <br />TI ASV2 <br />2.5" S.S. 0 -409F TEMPERATURE GAUGE <br />PI VER1 <br />FLOW METER (TOTALIZING) <br />DWYER MAGNEHELIC 2080 0 -80" WATER <br />PI VER2 <br />TI <br />DWYER MAGNEHELIC 2080 0 -80" WATER <br />PI VER3 <br />TEMPERATURE SWITCH HIGH <br />DWYER MAGNEHELIC 2030 0 -30" WATER <br />TI VER2 <br />— TI VER3 <br />2.5" S.S. 0 -200'F TEMPERATURE GAUGE <br />S VER1 — <br />S VER3 <br />1/4" BRASS BALL VALVE W/ 1/8" HOSE BARB <br />PI LC — <br />PI LC2 <br />2.5" S.S. LIQUID— FILLED 0 -60 PSI PRESSURE GAUGE <br />S LC1 — <br />S LC3 <br />1/4" BRASS BALL VALVE W/ 1 8" HOSE BARB <br />FQ1 LC2 <br />LSH <br />5/8" x 3/4" MASTERMETER W PULSE OUTPUT <br />PSL VER1 <br />LEVEL SWITCH HIGH HIGH <br />DWYER MODEL 1950P -2 (XP) W 0,5 -2 PSID RANGE <br />S VEW1 <br />— S VEW19 <br />1/4" BRASS BALL VALVE W/ 1 8" HOSE BARB <br />PI VEW1 <br />— PI VEW19 <br />DWYER MAGNEHELIC 2080 0 -80" WATER <br />LSL /LSH /LSHH <br />VER1 <br />CUSTOM MULTI— POSITION LEVEL PROBE <br />AC -1 <br />NORMALLY CLOSED <br />BECKER MODEL KDT 3.140 (12.0 HP, TEFC, 3 PHASE, 230 V) <br />B 1 <br />ROTRON MODEL EN909BG72WL (15 HP, XP, 3 PHASE, 230 V) <br />MS -1 <br />ROTRON MODEL MS6008S (40 GALLON CAPACITY) <br />AF -1 <br />ROTRON MODEL 516465 (4" DIAM.) <br />AF -2 <br />SOLBERG MODEL FS -31P -200 1.5 DIAMETER INLET /OUTLET <br />FS -1 <br />SOLBERG MODEL FS-31P-200 �1.5" DIAMETER INLET /OUTLET <br />FS -2 <br />SILENCER <br />HE -1 <br />THERMAL TRANSFER MODEL AA -50 -2 <br />PF -1 <br />KRYSTAL KLEAR MODEL 44SS <br />S VC1 — <br />S VC2 <br />1/4" BRASS BALL VALVE W/ 1/8" HOSE BARB <br />S -1 <br />SILENCER <br />S -2 <br />ROTRON MODEL 516264 (4" IN./OUT.) <br />TP -1 <br />MYERS MODEL CT05FAB (0.5 HP, XP, 3 PHASE) <br />CD -1 <br />CARBTROL MODEL HP -90 (90 lb CARBON, 10 GPM MAX.) <br />CD -2 — <br />CD -3 <br />CARBTROL MODEL G -7 (1600 lb CARBON, 2500 CFM MAX.) <br />TI /TSHEE <br />DWYER RRT2250U <br />THERMOCOUPLE <br />PHONETICS MODEL #FGD -005 <br />LSH I/G <br />GEMS -750 LEVEL SWITCH <br />DPI VER2 <br />DWYER MINIHELIC II MODEL 2 -5010 <br />TRAILER 'TIE DOWN DETAIL <br />SCALE: 1 " =3' <br />_— STUB— <br />T 1" (T) (r) t T <br />2 "0 SCH. <br />(1000(1O(1(1(1O(xxux) <br />40 PVC <br />(TO INFILTRATION — -- — — — — — -=r- <br />GALLERY) <br />VENT 2X <br />(LOW 3 41D) <br />G <br />11"0 ELECTRICAL A ! <br />CONDUIT (PROBE) — <br />(TO INFILTRATION \yc <br />GALLERY) <br />• �F <br />NOTES: 1) INSTALL ANCHORS PROXIMAL TO CORNERS OF TRAILER. <br />2) ANCHORS FROM MARATHON SERVICES, INC., PART #59080 <br />MODEL M12H5/8 <br />3) USE 2 BAGS (40 Ib.) OF CONCRETE PER ANCHOR. <br />� 1 1 1 .i. 1111 1 111 1 1 11 lit <br />r <br />� <br />i �' • <br />. , ��� <br />VENT <br />(LOW) <br />Cl C VENT <br />9 (LOO) <br />5 G -4 VAPOR PHASE G -4 VAPOR PHASE <br />CARBON DRUM CARBON DRUM <br />cP -s <br />cP - 1 <br />EXHAUST _O <br />STACK J <br />6' W000 FENCE <br />� \ <br />3 5 <br />4' LOCKING GATE <br />22' <br />EQUIPMENT PAD r <br />©v <br />DRAWING CONFIDENTIAL: <br />THIS DRAWING AND ALL INFORMATION <br />CONTAINED THEREON IS AND SHALL RE- <br />MAIN THE PROPERTY OF HANDEX OF <br />FLORIDA, INC. AS AN INSTRUMENT <br />OF PROFESSIONAL SERVICE. THIS <br />INFORMATION SHALL NOT BE USED <br />WITHOUT THE FULL KNOWLEDGE <br />AND PRIOR WRITTEN CONSENT <br />OF HANDEX OF FLORIDA, INC. / <br />SCALE VERIFICATION <br />THIS BAR REPRESENTS <br />ONE INCH ON THE <br />ORIGINAL DRAWING <br />0 1" <br />USE TO VERIFY FIGURE <br />►I <br />AIR SPARGE <br />MANIFOLD <br />(29 POINTS) <br />AIR SPARGE WELLS <br />AS -1 THROUGH <br />AS -29 <br />F - - <br />a <br />f <br />REVISION DATE DESCRIPTION BY APPROVED <br />SCALE: 1"=3' <br />VERTICAL SVE <br />WELLS <br />SVE -1 THROUGH <br />SVE -19 <br />AF -2 AIR IN <br />FS -2 <br />BLEED <br />VALVE <br />PI TI PI * * TI <br />svz sv2 sV I sv+ <br />INSTRUMENTATION: <br />INSTRUMENT TYPE —'� PI <br />SYSTEM DESIGNATION _ VE1 s SYSTEM POSITION NUMBER <br />0 LOCAL MOUNTED INSTRUMENT <br />INSTRUMENTS WITH INPUTS OR OUTPUTS <br />AT THE SITE CONTROL PANEL <br />PILOT LIGHT OR ALARM INDICATOR <br />AC -1 LIGHT <br />PI TSH TA <br />HE-1 S -1 �} <br />sv s <br />sv <br />1 s TI <br />I I 1 F F <br />E <br />U I (— <br />jl 011 ul <br />�II <br />swy I NI �II r - - - - -- O z <br />PI I I �- - -- I I 1 0 <br />- - --� 1113 0 <br />I I I ICI U <br />LIGHT <br />I T i T z E 1 �I 11 II — TELEMETRY — <br />1 PHONE LINE <br />tl <br />I I - - - - -- i <br />240 VAC, 30 <br />1 �1 1 1 11 1 <br />1----------------- - --=1 1 1 11 I <br />SVE MANIFOLD F_ 1 -- — — — — — <br />(19 POINTS) <br />I LA <br />'E <br />AS /VE SYSTEM <br />CONTROL PANEL <br />(MOUNTED OUTSIDE <br />OF TRAILER) <br />)40 VAC, 30 <br />VER+ <br />SL I S I FS -1 <br />VF + I _ gl <br />S r1 PI <br />1 S PI PI S I I I — PI S TI B - ER VER VER <br />E11 vER+ vER+ MS -1 R2 ER VER S— <br />1 <br />°RZ L� <br />MANUAL DRAIN <br />VALVE (N.C.) N L BYPASS <br />I ** <br />TO-1 C LC2 CS <br />I � F01 CD -1 <br />I <br />C <br />BYPASS VALVE <br />AS /SVE SYSTEM <br />IN ENCLOSED TRAILER <br />ENGINEER OF RECORD: <br />3/ <br />VICT RIA H. LYNCH P.E. DATE <br />FLA. REG. #49654 SIGNED: <br />CAD FILE: A 171 DT 1 SCALE: NA <br />DRAWN BY: J.ROBINSON DATE: 03 -07 -03 <br />CHECKED BY: DATE: <br />APPROVED BY: DATE: <br />S <br />S AIR OUT <br />VC <br />VC2 (STACK) <br />PAN <br />CD -2 <br />CD -3 <br />33619 <br />® <br />Practical Environmental Solutions <br />Telephone (813) 626 - 4646 <br />Fax (813) 626 -1898 <br />FLOW METER <br />FQI <br />FLOW METER (TOTALIZING) <br />FS <br />FLOW SWITCH <br />TI <br />TEMPERATURE INDICATOR <br />TSH <br />TEMPERATURE SWITCH HIGH <br />TSL <br />TEMPERATURE SWITCH LOW <br />TT <br />TEMPERATURE TRANSDUCER <br />TAH <br />TEMPERATURE ALARM HIGH <br />TAIL <br />TEMPERATURE ALARM LOW <br />LSLL <br />LEVEL SWITCH LOW LOW <br />LSL <br />► TO INFILTRATION GALLERY <br />TO INFILTRATION GALLERY (LEVEL SWITCH) <br />INSTRUMENT TYPE/ <br />DESIGNATION: <br />PI <br />NONOXIr H ANDr.,,& <br />111 Kelsey <br />Suite E <br />Lane <br />PAN <br />PRESSURE ALARM HIGH <br />Tampa, Florida <br />33619 <br />® <br />Practical Environmental Solutions <br />Telephone (813) 626 - 4646 <br />Fax (813) 626 -1898 <br />INSTRUMENT TYPE/ <br />DESIGNATION: <br />PI <br />PRESSURE INDICATOR <br />PSL <br />PRESSURE SWITCH LOW <br />PAN <br />PRESSURE ALARM HIGH <br />PAL <br />PRESSURE ALARM LOW <br />A <br />FLOW INDICATOR <br />FM <br />FLOW METER <br />FQI <br />FLOW METER (TOTALIZING) <br />FS <br />FLOW SWITCH <br />TI <br />TEMPERATURE INDICATOR <br />TSH <br />TEMPERATURE SWITCH HIGH <br />TSL <br />TEMPERATURE SWITCH LOW <br />TT <br />TEMPERATURE TRANSDUCER <br />TAH <br />TEMPERATURE ALARM HIGH <br />TAIL <br />TEMPERATURE ALARM LOW <br />LSLL <br />LEVEL SWITCH LOW LOW <br />LSL <br />LEVEL SWITCH LOW <br />LSM <br />LEVEL SWITCH MIDRANGE <br />LSH <br />LEVEL SWITCH HIGH <br />LSHH <br />LEVEL SWITCH HIGH HIGH <br />LAL <br />LEVEL ALARM LOW <br />LAH <br />LEVEL ALARM HIGH <br />CS <br />CAPACITIVE SENSOR <br />S <br />SAMPLE PORT <br />VB <br />VACUUM BREAK <br />N.C. <br />NORMALLY CLOSED <br />SYSTEM DESIGNATION: <br />ASW AIR SPARGE WELL & MANIFOLD <br />VEW VAPOR EXTRACTION WELL & MANIFOLD <br />VER VAPOR EXTRACTION REGENERATIVE BLOWER <br />ASV AIR SPARGE ROTARY VANE COMPRESSOR <br />VC VAPOR PHASE CARBON <br />LC LIQUID PHASE CARBON <br />EE EQUIPMENT ENCLOSURE <br />VALVES: <br />GLOBE VALVE <br />(� SWING CHECK VALVE <br />Im I BALL CHECK VALVE <br />�— VACUUM RELIEF VALVE <br />PRESSURE RELIEF VALVE <br />BALL VALVE <br />GATE VALVE <br />BUTTERFLY VALVE <br />DIAPHRAGM VALVE <br />NEEDLE VALVE <br />EQUIPMENT SYMBOLS: <br />® SILENCER <br />AIR FILTER <br />TRANSFER PUMP <br />MS MOISTURE SEPARATOR <br />AIR LINE <br />— — — — — CONTROL LINE <br />WATER LINE <br />FLOW DIRECTION <br />PARTICLE FILTER <br />LIQUID PHASE <br />CARBON VESSEL <br />* * CRITICAL SAFETY DEVICE <br />LEGEND <br />TT Tr <br />VAPOR PHASE <br />CARBON VESSEL <br />REGENERATIVE VACUUM <br />BLOWER ROTRON EN858 <br />ROTARY VANE BECKER <br />AIR COMPRESSOR <br />} MULTI- POSITION <br />I LEVEL SWICTH <br />AMOCO- #171 <br />