Laserfiche WebLink
SPEOIFICtiil0NS for Police Station & Court Room Addi4?.cn to <br /> The Zephyrhills Municipal building <br /> FCOT hG: bhall be 10" X 214" - j,000 PSI concrete -with <br /> four #5 reinforcing bare - continuous. <br /> F UNDAT i0N x L'hall be 8" X 12" X 16" Ocala ltlock and all <br /> cells filled with concrete - #L bars to be <br /> placed vertical on 2: centers. <br /> FLOUR: -hall be k" - 3,000 PSI concrete, with 6" X 6" <br /> mesh #10 gage steel wire for reinforcement, blab <br /> will be poured over compacted fill using 6 Mil <br /> po]yethelene for vapor ,barrier. before placement <br /> of concrete slab all compacted fill will be treated <br /> for termite control. <br /> EXTERIOR WALLS: Shall be 8* X 8" X 16" Ocala block, <br /> ith Dor-O -Wall placed every other horizonal <br /> joint starting in second joint above floor. Joints <br /> will be raked Loth vertical and horizonl to match <br /> existing building All cores as shown on sheet 1 <br /> (General Notes) 1 & 2, shall be poured. U lintel <br /> blocks as per plan shall be filled with concrete <br /> With 2 "5 reinforcing tars continuous and joist <br /> anchors set. <br /> STRUCTURAL STEEL: Steel Joist shall be 18 S 8 (open web <br /> type) to conform with existing building. t' round <br /> rod bridging top and bottom as per plan. Joist <br /> shall be welded to existing steel and steel anchors <br /> shere supported by masonry walls. <br /> C �o� <br />