Laserfiche WebLink
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Zephyrhills Professional Park 2272 Jaudon Road <br /> 37900 Daughtery Road Dover, FL 33527 <br /> Zephyrhills, FL 813- 655 -3373 <br /> FCO Letters F 813- 655 -9814 <br /> Design per 2007 Florida Building Code, 2009 supplement, Section 16 Wind Load <br /> ASCE 7 -05 <br /> I Aaron Biedenbach, P.E. <br /> Design Specifications I FL PE #52949, FL EB 9394 <br /> Importance Factor 1 OH PE 60756, OC #01893 <br /> Kzt 1 KY PE #20281, P #2463 <br /> Exposure Factor B IN PE #PE 19600322 <br /> Kd 1 FL CBC #060535, QB #22527 <br /> Kz 0.7 <br /> V 110 mph <br /> GCp -GCpi 1.28 Zone 4, h < 60 <br /> Wind Pressure 27.8 (psf) <br /> Sign Information per Letter <br /> Height 4.25 (ft) f f f / // /��� <br /> Width 4.25 (ft) g1ED <br /> Thickness 0.05 (ft) ‘111114; • . • • • s • • 1 �� <br /> D istance grade to top 15 (ft) N 0 . %C <br /> • <br /> N 8E •• 0 y <br /> �Q•�' A9 • <br /> Wind Sheer Force 5.90 (Ib) : Q : N * • <br /> • w <br /> Weight of Sign 1 (Ib) Of • W ` <br /> Total Sheer Force = 5.98 (Ib) • 'A ?: • <br /> Total Tension Force = 501.32 (Ib) % AL �` <br /> 11 /1/11 11 <br /> Required Provided <br /> Fastener size (Nominal) 1/8 1/8 <br /> Minimum number of fasteners per letter 2 2 <br /> Sheer Force per fastener (Ib) 3.0 10 <br /> Tension Force per fastener (Ib) 250.7 10 <br /> Combination Tension and 25.36 <1 O.K. <br /> Sheer ratio <br /> Fastener to be 1/8" stud epoxied into structure. 1" embedment <br /> 11/24/2010 <br /> Zephyrhills Professional Park FCO <br />