Laserfiche WebLink
"L TM <br /> 77MBERLINEUFEW / MBERL/NE:77 IOH DLFIMITIOM tHIMOL WS MOM OLR /MITIOIV'tM/MOLLt -• - <br /> 7 T MBERLINE /OM OLP aHIMOLit tN/NOLLi <br /> APPLICATION INSTRUCTIONS <br /> English <br /> For Mal Pattern <br /> Enpn9a Sign 1xn3S Isar.SUnm, Sir IIW Patten) <br /> Note: These shingles MUST be N.-W(232-.2.4 w_xp„_a <br /> nailed a nominal 5 5/8" (143mm) ff- leas -ssgy p - w� - �I o - .,m - •/ " _ <br /> from bottom of shingles, not in or w, l ( -x �cn_w, "� °" • "° <br /> i v - avr n - w \ arr,n -w <br /> above self seal, as shown. Nails <br /> should remain unexposed. I _.._f I <br /> f a„ r _ <br /> It yr <br /> I,a- utnlw ! F i I ! i iut -u <br /> l I 1 j <br /> 'bp„q b 1 -Vrw i- q"ImYO•>+ uamnsprnq. <br /> GENERAL INSTRUCTIONS <br /> • ROOF DECKS: Wood decks must be well- seasoned, (25mm) up from bottom of the shingle. Press shingle firmly into <br /> supported, and tightly- constructed with maximum 6" (152mm) the adhesive. For maximum wind resistance along rakes, install <br /> wide lumber, having adequate nail - holding capacity and a smooth GAF -Elk Starter Strip Shingles with GAF -Elk Dura -Grip° sealant or <br /> surface. Plywood or OSB decking as recommended by APA -The cement shingles to underlayment and each other in a 4' (102mm) <br /> Engineered Wood Assn. is acceptable. Do not fasten shingles width of asphalt plastic cement. Caution: Apply ONLY a thin <br /> directly to insulation or insulated deck unless authorized in writing uniform layer of asphalt plastic cement less than 1/8' (3mm) thick. <br /> by GAF -Elk. Roof decks and existing surfacing material must be Excess amounts can cause blistering of the shingles and may <br /> dry prior to application of shingles. soften the asphalt in certain underlayments, including <br /> • UNDERLAYMENT: Underlayment beneath shingles has many StormGuards, Weather Watch' and other GAF -Elk Leak Barriers, <br /> benefits, including preventing wind - driven rain from reaching the resulting in the asphalt flowing, dripping and staining. <br /> interior of the building and preventing sap in some wood decking • RELEASE FILM: The film strips on the back of each shingle <br /> from reacting with asphalt shingles.Underlayment is also required are to prevent sticking together of the shingles while in the bundle. <br /> by many code bodies and is required to maintain the UL Class A Their removal is NOT required during application. <br /> fire rating. Where an underlayment is to be installed, use • MANSARD AND STEEP SLOPE APPLICATIONS: For <br /> a breather -type underlayment such as GAF -Elk Shingle- Mate, roof slopes greater than 21' per foot (1750mm /m), shingle must be <br /> Leatherback' or Deck- Armor underlayment. hand sealed (DO NOT use on vertical side walls). See "Wind <br /> • FASTENERS: Use only zinc- coated steel or aluminum, 10 -12 Resistance/Hand Sealing" for the application of adhesive. <br /> gauge, barbed, deformed or smooth shank roofing nails with heads • SHINGLE TAB ADHESIVE: Use asphalt plastic cement <br /> 3/8' (10mm) to 7/16' (12mm) in diameter. Fasteners should be conforming to ASTM D4586 Type I or II. <br /> long enough to penetrate at least 3/4' (19mm) into wood decks or • THROUGH VENTILATION: All roof structures must be <br /> just through the plywood decks. Fasteners must be driven flush provided with through ventilation to prevent entrapment of <br /> with the surface of the shingle. Overdriving will damage the moisture -laden air behind roof sheathing. Proper ventilation is also <br /> shingle. Raised fasteners will interfere with the sealing of the necessary to prevent mold growth. Ventilation provisions must at <br /> shingles and can back out. least meet or exceed current F.H.A., H.U.D. or local code minimum <br /> • WIND RESISTANCE/HAND SEALING: These shingles have requirements. Note: Minimum net free ventilation area of 1 sq. foot <br /> a special thermal sealant that firmly bonds the shingles together per 150 sq. feet (1 sq. meter per 150 sq. meters) of ceiling area is <br /> after application when exposed to sun and warm temperatures. required. When vents are located at the eaves and near the roof's <br /> Shingles installed in Fall or Winter may not seal until the following peak (balanced) for maximum air flow, ventilation may be reduced <br /> Spring. If shingles are damaged by winds before sealing or are not to 1 sq. foot per 300 sq. feet (1 sq. meter per 300 sq. meters). <br /> exposed to adequate surface temperatures, or if the self - sealant • NON - CORRODING METAL DRIP EDGES: Recommended <br /> gets dirty, the shingles may never seal. Failure to seal under these along rake and eave edges on all decks, especially plywood decks. <br /> circumstances results from the nature of self - sealing shingles and • EXPOSED METAL: All exposed metal surfaces (flashing, <br /> is not a manufacturing defect. To insure immediate sealing, apply 4 vents, etc.) should be painted with matching GAF -Elk roof <br /> quarter -sized dabs of shingle tab adhesive on the back of the accessory paint. <br /> shingle 1' (25mm) and 13" (330mm) in from each side and 1' <br />