APPROVED ASSEMBLY <br /> sup•.... System A: Country Manor Shakes <br /> Deck Type: Wood, Non - insulated <br /> Deck Description: Min. 15 /32" Plywood, or Wood Plank )11 <br /> Slope Range: 2 ":12" or greater <br /> Maximum Uplift <br /> Pressure: The maximum allowable design pressure for system A shall be —75 psf. <br /> Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d <br /> annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than <br /> 19 /32" thick Minimum 15 / 32 ") The above attachment method must be in addition to _ <br /> existing attachment. <br /> Underlayment: Minimum underlayment shall be a double layer underlayment system comprised <br /> of a #15 felt (ASTM D 226, typel) applied with a 50% overlap or application of a <br /> #30 felt (ASTM D 226, type II) or #43 coated base sheet (ASTM D 2626) installed <br /> with a minimum 6" side laps and 2" head laps. Underlayment shall be fastened <br /> with corrosion resistant tin -caps and 1 V4" annular ring shank nails, spaced 6" o.c. <br /> at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any other <br /> approved underlayment having a current NOA. <br /> Note: All flashing cement used shall be ASTM D 4586 asbestos -free flashing cement. I <br /> products shall have Miami -Dade Component Approval. <br /> Fire Barrier Any approved fire barrier having a current NOA. Or for class A o <br /> Board: install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA or <br /> minimum 4mm thick of Tritex, RockRoof (with current NOA) or 5 / water <br /> resistant type X gypsum sheathing with treated core and facer. <br /> Valleys: Valley construction shall be in compliance with Roofing Application Standard <br /> RAS 133 and with Classic Metal Roofing System's current installed instructions. <br /> Metal Panels and Install Country Manor Shake, and accessories in compliance with Classice Metal <br /> Accessories: Roofing System's current published installation instructions and details. Flashing, <br /> penetrations, valley construction and other details shall be constructed in <br /> compliance with the minimum requirements provided in Roofing Application <br /> Standard RAS 133. <br /> All work shan Prevailin mj With for plumbing ele/nca1, . building, <br /> gas, Pooh and �. structures <br /> s <br /> � �� �2, NOA No.: 07- 0807.01 <br /> t °' � Expiration Date: 11/18/12 <br /> Approval Date: 12/13/07 <br /> . ro Page 3 of 4 <br /> ' I:Yt y <br />