Laserfiche WebLink
Porch enclosures, screen room enclosure, garage enclosures <br /> and additions <br /> 1) All enclosures shall meet the 2007 F.B.C. and 2008 N.E.0 codes. <br /> 2) All rooms that do not meet the definition of a category 1 -3 sunroom will be considered habitable and <br /> conditioned space. <br /> 3) Energy calculations shall be provided to enclose porches, screen rooms, garages, and additions if it <br /> does not meet the definition of a category 1 -3 sunroom. <br /> 4) A minimum R -value of 11 is required for walls and R -19 for ceilings. <br /> 5) If space is used as storage or utility, it shall be listed on permit as such. <br /> 6) If space is used as storage or utility, all doors shall be solid core doors and shall not open into rooms <br /> used for sleeping. Doors shall also be rated as a 20 minute fire rated door. R309.1 <br /> 7) If space is used as storage or utility, it shall be separated by not Tess than 1/2 inch gypsum board from <br /> its residence and its attic. R309.2 <br /> 8) Floor surfaces of garages shall be of approved noncombustible material. <br />